3 resultados para step-down converter
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
In recent years, there was an increase of ancillary service loads, such as signaling systems, inspection robots, surveillance cameras, and other monitoring devices distributed along high-voltage transmission lines which require low-power dc voltage supplies. This paper investigates the use of the induced voltage in the shield wires of an overhead 525 kV transmission line as a primary power source. Since phase current variations throughout the day affect the induced voltage in the overhead ground wire, a step-down dc-dc converter is used after rectification of the ac voltage to provide a regulated dc output voltage. The initial encouraging results obtained indicate that this form of power supply can be a feasible and cost-effective alternative for feeding small ancillary service loads. The simulation results are validated by field measurements as well as the installation of a 200 W voltage stabilization system prototype.
Resumo:
Introduction: Nurse understaffing is frequently hypothesized as a potential risk factor for healthcare-associated infections (HAI). This study aimed to evaluate the role of nursing workload in the occurrence of HAI, using Nursing Activities Score (NAS). Methods: This prospective cohort study enrolled all patients admitted to 3 Medical ICUs and one step-down unit during 3 months (2009). Patients were followed-up until HAI, discharge or death. Information was obtained from direct daily observation of medical and nursing rounds, chart review and monitoring of laboratory system. Nursing workload was determined using NAS. Non-compliance to the nurses' patient care plans (NPC) was identified. Demographic data, clinical severity, invasive procedures, hospital interventions, and the occurrence of other adverse events were also recorded. Patients who developed HAI were compared with those who did not. Results: 195 patients were included and 43 (22%) developed HAI: 16 pneumonia, 12 urinary-tract, 8 bloodstream, 2 surgical site, 2 other respiratory infections and 3 other. Average NAS and average proportion of non compliance with NPC were significantly higher in HAI patients. They were also more likely to suffer other adverse events. Only excessive nursing workload (OR: 11.41; p: 0.019) and severity of patient's clinical condition (OR: 1.13; p: 0.015) remained as risk factors to HAI. Conclusions: Excessive nursing workload was the main risk factor for HAI, when evaluated together with other invasive devices except mechanical ventilation. To our knowledge, this study is the first to evaluate prospectively the nursing workload as a potential risk factor for HAI, using NAS.
Resumo:
The Nd3+-Yb3+ couple was investigated in fluoroindogallate glasses using optical spectroscopy to elucidate the energy transfer mechanisms involved in the downconversion (DC) process. Upon excitation of a Nd3+ ion by an ultraviolet photon, DC through a three-step energy transfer process occurs, in which the energy of the ultraviolet photon absorbed by the Nd3+ ion is converted into three infrared photons emitted by Yb3+ ions, i.e. quantum cutting (QC). In addition, with excitation in the visible, our results confirm that the DC process occurs through a one-step energy transfer process, in which the energy of a visible photon absorbed by the Nd3+ ion is converted into only one infrared photon emitted by an Yb3+ ion. Time-resolved measurements enabled the estimation of the efficiencies of the cross-relaxation processes between Nd3+ and Yb3+ ions.