2 resultados para steam injection continuous

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In contrast to the impressive advances in somatic research of erectile dysfunction (ED), scientific literature shows contradictory reports on the results of psychotherapy for the treatment of ED. Authors conducted a meta-analysis to evaluate the effectiveness of psychological interventions for the treatment of ED compared to oral drugs, local injection, vacuum devices, or other psychological intervention. Distinct sources of randomized controlled trials (RCTs) were searched: electronic databases (between 1966 and 2007), cross checking of references, and contact with scientific societies. For dichotomous outcomes the pooled relative risks were calculated and for continuous outcomes mean differences between interventions. Statistical heterogeneity was addressed. Eleven RCTs involving 398 men met the inclusion criteria. There is evidence that group therapy improves ED. Focused sex group therapy showed greater efficacy than control group. Men randomized to receive psychotherapy plus sildenafil showed significant improvement of ED and were less likely than those receiving only sildenafil to drop out. Regarding to the effectiveness of psychological interventions for the treatment of ED compared to local injection and vacuum devices no difference was found. Melnik T, Soares BGO, and Nasello AG. The effectiveness of psychological interventions for the treatment of erectile dysfunction: Systematic review and meta-analysis, including comparisons to sildenafil treatment, intracavernosal injection, and vacuum devices. J Sex Med 2008;5:2562-2574.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article describes a new design for a paper-based electrochemical system for flow injection analysis. Capillary wicking facilitates a gravity-driven flow of buffer solution continuously through paper and nitrocellulose, from a buffer reservoir at one end of the device to a sink at the other. A difference in height between the reservoir and the sink leads to a continuous and constant flow. The nitrocellulose lies horizontally on a working electrode, which consists of a thin platinum layer deposited on a solid support. The counter and reference electrodes are strategically positioned upstream in the buffer reservoir. A simple pipetting device was developed for reliable application of (sub)microliter volumes of sample without the need of commercial micropipets; this device did not damage the nitrocellulose membrane. Demonstration of the system for the determination of the concentration of glucose in urine resulted in a noninvasive, quantitative assay that could be used for diagnosis and monitoring of diabetes. This method does not require disposable test strips, with enzyme and electrodes, that are thrown away after each measurement Because of its low cost, this system could be used in medical environments that are resource-limited.