12 resultados para single-electron tunneling (SET)
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Objectives. To purpose a method for predicting the shrinkage stress development in the adhesive layer of resin-composite cylinders that shrink bonded to a single flat surface, by measuring the deflection of a glass coverslip caused by the shrinkage of the bonded cylinders. The correlation between the volume of the bonded resin-composite and the stress-peak was also investigated. Methods. A glass coverslip deflection caused by the shrinkage of a bonded resin-composite cylinder (diameter: d = 8 mm, 4 mm, or 2 mm, height: h = 4 mm, 2 mm, 1 mm, or 0.5 mm) was measured, and the same set-up was simulated by finite element analysis (3D-FEA). Stresses generated in the adhesive layer were plotted versus two geometric variables of the resin-composite cylinder (C-Factor and volume) to verify the existence of correlations between them and stresses. Results. The FEA models were validated. A significant correlation (p < 0.01, Pearson's test) between the stress-peak and the coverslip deflection when the resin-composites were grouped by diameter was found for diameters of 2 and 4 mm. The stress-peak of the whole set of data showed a logarithmic correlation with the bonded resin-composite volume (p < 0.001, Pearson's test), but did not correlate with the C-Factor. Significance. The described method should be considered for standardizing the stress generated by the shrinkage of resin-composite blocks bonded to a single flat surface. (C) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Sarmento C. A. P., Ferreira A. O., Rodrigues E. A. F., Lesnau G. G., Rici R. E. G., Abreu D. K., Biasi C. & Miglino M. A. 2012. [Kidney of Minke Whale (Baleanoptera acutorostrata): Architecture and structure.] Rins de Baleia Minke (Baleanoptera acutorostrata): arquitetura e estrutura. Pesquisa Veterinaria Brasileira 32(8): 807-811. Departamento de Cirurgia, Setor de Anatomia dos Animais Domesticos e Silvestres, Universidade de Sao Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, Sao Paulo, SP 05508-270, Brazil. E-mail: sarmento@usp.br Among marine mammals, whale is one of the most attention-arousing animals, especially concerning its urinary tract. This system follows the pattern of mammals with regard to its constitution, however, it differs in renal morphology and number of lobes, which, in turn, form complete reniculi, agglutinated in hundreds. This structure is supported by fibrous connective tissue, but highly capable of maintaining electrolyte balance. Six pairs of kidneys of Minke whale (Balaenoptera acutorostrata), collected in 1982, in Cabedelo, Paraiba, Brazil, in the last fishing allowed, were dissected. These kidneys were preserved in 10% formaldehyde and they presented a very large histologic layer of collagen surrounding the medullary wall. The urinary collecting duct form papillary glasses, that reach a single collecting center which discharges in the ureter. It was found that the kidney of Minke whale has a lobe characteristic, with, on average, 700 reniculi; each reniculus has anatomical and functional characteristics of a unipyramidal kidney, with an inner layer (medulla), and an outer layer (cortex), and independent irrigation, with formation of individually arcuate arteries, as observed in unipyramidal terrestrial mammals. However, the set gathering all these reniculi constitutes, in the end, a multilobular and polipyramidal kidney, contrary to the morphology of most terrestrial mammals. It was not possible to distinguish the renicular cortex structures of the Minke whale in the level of light microscopy. Through scanning electron microscopy, it was possible to visualize a cortical layer located between two fibrous capsules. This joint, in turn, consists of connective tissue, which, along with a layer of collagen and elastic fibers, separates the cortex from the medulla; the kidney glomeruli were visualized, completely taken by the glomerular vessels and arranged into several layers. One notices that the glomerular cavity is almost a virtual space into which the glomerular filtrate is drained, and it does not present a globular shape. Vascularization is increased in the medullary region. The difference between the kidneys of terrestrial and marine mammals consists in the arrangement of morphological components, favoring the organ's physiology.
Resumo:
Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4748519]
Resumo:
The single machine scheduling problem with a common due date and non-identical ready times for the jobs is examined in this work. Performance is measured by the minimization of the weighted sum of earliness and tardiness penalties of the jobs. Since this problem is NP-hard, the application of constructive heuristics that exploit specific characteristics of the problem to improve their performance is investigated. The proposed approaches are examined through a computational comparative study on a set of 280 benchmark test problems with up to 1000 jobs.
Resumo:
The classical magnetoresistance of a two-dimensional electron gas constrained to non-planar topographies, in antidot lattices, and under the influence of tilted magnetic field in arbitrary direction is numerically studied. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Measurement-based quantum computation is an efficient model to perform universal computation. Nevertheless, theoretical questions have been raised, mainly with respect to realistic noise conditions. In order to shed some light on this issue, we evaluate the exact dynamics of some single-qubit-gate fidelities using the measurement-based quantum computation scheme when the qubits which are used as a resource interact with a common dephasing environment. We report a necessary condition for the fidelity dynamics of a general pure N-qubit state, interacting with this type of error channel, to present an oscillatory behavior, and we show that for the initial canonical cluster state, the fidelity oscillates as a function of time. This state fidelity oscillatory behavior brings significant variations to the values of the computational results of a generic gate acting on that state depending on the instants we choose to apply our set of projective measurements. As we shall see, considering some specific gates that are frequently found in the literature, the fast application of the set of projective measurements does not necessarily imply high gate fidelity, and likewise the slow application thereof does not necessarily imply low gate fidelity. Our condition for the occurrence of the fidelity oscillatory behavior shows that the oscillation presented by the cluster state is due exclusively to its initial geometry. Other states that can be used as resources for measurement-based quantum computation can present the same initial geometrical condition. Therefore, it is very important for the present scheme to know when the fidelity of a particular resource state will oscillate in time and, if this is the case, what are the best times to perform the measurements.
Resumo:
Objectives: Because the mechanical behavior of the implant-abutment system is critical for the longevity of implant-supported reconstructions, this study evaluated the fatigue reliability of different implant-abutment systems used as single-unit crowns and their failure modes. Methods and Materials: Sixty-three Ti-6Al-4V implants were divided in 3 groups: Replace Select (RS); IC-IMP Osseotite; and Unitite were restored with their respective abutments. Anatomically correct central incisor metal crowns were cemented and subjected to separate single load to failure tests and step-stress accelerated life testing (n = 18). A master Weibull curve and reliability for a mission of 50,000 cycles at 200 N were calculated. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The load at failure mean values during step-stress accelerated life testing were 348.14 N for RS, 324.07 N for Osseotite, and 321.29 N for the Unitite systems. No differences in reliability levels were detected between systems, and only the RS system mechanical failures were shown to be accelerated by damage accumulation. Failure modes differed between systems. Conclusions: The 3 evaluated systems did not present significantly different reliability; however, failure modes were different. (Implant Dent 2012;21:67-71)
Resumo:
The electronic interactions between the [Cu(opba)]2- anions (where opba is orthophenylenebis (oxamato)) and single-wall carbon nanotubes (SWCNTs) were investigated by resonance Raman spectroscopy. The opba can form molecular magnets, and the interactions of opba with SWCNTs can produce materials with very different magnetic/electronic properties. It is observed that the electronic interaction shows a dependence on the SWCNT diameter independent of whether they are metallic or semiconducting, although the interaction is stronger for metallic tubes. The interaction also is dependent on the amount of complex that is probably adsorbed on the carbon surface of the SWCNTs. Some charge transfer can be also occurring between the metallic complex and the SWCNTs. Copyright (c) 2012 John Wiley & Sons, Ltd.
Resumo:
The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface with scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments (milled CoCr collar rotational and non-rotational) and another of an alternative manufacturer (Microplant) in randomly arranged I/A combinations. The degree of interchangeability between the various brands of components was defined using the original abutment interface gap with its respective implant as the benchmark dimension. Accordingly, when the result for a given component placed on an implant was equal to or smaller then that gap measured when the original component of the same brand as the implant was positioned, interchangeability was considered valid. Data were compared with the Kruskal-Wallis test at 5% significance level. Some degree of misfit was observed in all specimens. Generally, the non-rotational component was more accurate than its rotational counterpart. The latter samples ranged from 0.6-16.9 µm, with a 4.6 µm median; and the former from 0.3-12.9 µm, with a 3.4 µm median. Specimens with the abutment and fixture from Conexão had larger microgap than the original set for SIN and Neodent (p<0.05). Even though the latter systems had similar results with their respective components, their interchanged abutments did not reproduce the original accuracy. The results suggest that the alternative brand abutment would have compatibility with all systems while the other brands were not completely interchangeable.
Resumo:
High quality KMo4O6 single crystals with tetragonal structure (space group P4/mbm) have been prepared by fused salt electrolysis. The crystals were studied by scanning electron microscopy (SEM), X-ray diffractometry, electrical resistivity, and magnetization measurements. X-ray powder diffraction patterns and SEM have given some information on the growth of single crystals. Electrical resistivity as a function of temperature shows that the KMo4O6 compound is a bad metal with resistivity change of approximately 30% in the temperature range from 2 to 300K. A metal-insulator transition (MIT), observed at approximately 110K, has been also confirmed for this material. Magnetization as a function of temperature agrees with previous report, however a magnetic ordering has been observed in M(H) curves in the whole temperature range.
Resumo:
This paper discusses the theoretical and experimental results obtained for the excitonic binding energy (Eb) in a set of single and coupled double quantum wells (SQWs and CDQWs) of GaAs/AlGaAs with different Al concentrations (Al%) and inter-well barrier thicknesses. To obtain the theoretical Eb the method proposed by Mathieu, Lefebvre and Christol (MLC) was used, which is based on the idea of fractional-dimension space, together with the approach proposed by Zhao et al., which extends the MLC method for application in CDQWs. Through magnetophotoluminescence (MPL) measurements performed at 4 K with magnetic fields ranging from 0 T to 12 T, the diamagnetic shift curves were plotted and adjusted using two expressions: one appropriate to fit the curve in the range of low intensity fields and another for the range of high intensity fields, providing the experimental Eb values. The effects of increasing the Al% and the inter-well barrier thickness on Eb are discussed. The Eb reduction when going from the SQW to the CDQW with 5 Å inter-well barrier is clearly observed experimentally for 35% Al concentration and this trend can be noticed even for concentrations as low as 25% and 15%, although the Eb variations in these latter cases are within the error bars. As the Zhao's approach is unable to describe this effect, the wave functions and the probability densities for electrons and holes were calculated, allowing us to explain this effect as being due to a decrease in the spatial superposition of the wave functions caused by the thin inter-well barrier.
Resumo:
A low energy electron may attach to a molecule, forming a metastable resonance, which may dissociate into a stable anion and a neutral radical. Chloromethane has been a good target for dissociative electron attachment studies, since it is a small molecule with a clear dissociative ‘sigma*’ shape resonance. We present potential energy curves for CH3Cl and its anion, as a function of the C-Cl distance. Due to the resonant nature of the anion, a correct description requires a treatment based on scattering calculations. In order to compute elastic cross sections and phase shifts we employed the Schwinger multichannel method, implemented with pseudopotentials of Bachelet, Hamann and Schlüter, at the static-exchange plus polarization approximation. At the equilibrium geometry, the resonance was found arround 3.3 eV, in accordance to experience. The incoming electron is captured by a ‘sigma*’ orbital located at the C-Cl bond, which will relax in the presence of this extra electron. We took this bond as the reaction coordinate, and performed several scattering calculations for a series of nuclear conformations. The phase shift obtained in each calculation was fitted by a two component function, consisting in the usual Breit-Wigner profile, which captures the resonant character, and a second order polynomial in the wave number, which accounts for the background contribution. That way, we obtained position and width of the resonance, which allowed us to build the potential energy curve. For larger distances, the anion becomes stable and usual electronic structure calculations suffice. Furthermore, the existence of a dipole-bound anion state is revealed when we employed a set of very diffuse functions. The knowledge on the behaviour of the neutral and anionic electronic states helps us in elucidating how the dissociation takes place.