12 resultados para semiconducting II-V materials

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Brazil, Protected Areas (PAs) are considered the cornerstone for development of national strategies for biodiversity conservation. Considering this point of view we analyzed thirty protected areas belonging to Atlantic Central Corridor of Atlantic Forest in Bahia, aiming to identify and analyze its current level of implementation. Lemos de Sa and Ferreira (2000) methodology which consist of applying a standard scale, where the variation of the level of implementation conforms to a range of 0 to 5 points was used, with appropriate adaptations. After obtaining the data from the implementation level we use the aggregation method of Ward to help visualize the dissimilarity between the protected areas studied. We used an international classification proposed by IUCN (International Union for Conservation of Nature) for that the UCs to be compared with works done in another countries, the UCs considered are in the groups Ia, II, V and VI da IUCN. As results, 50% of protected areas analyzed are reasonably implemented, 40% inadequately implemented, 6.7% are presented only on paper and only 3.3% can be classified as satisfactorily implemented. These areas presents problems in their regularization; deficiency in infrastructure, human and financial resources. Given the results its clear the recurrent fact that conservation areas under study must be effectively implemented and for this to occur environmental policies should be focused on actions to consolidate the goals of conservation strategy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

No Brasil, as Unidades de Conservação (UCs) são consideradas o pilar central para o desenvolvimento de estratégias nacionais de conservação da biodiversidade. Dentro dessa perspectiva, foram estudadas trinta unidades de conservação pertencentes ao Corredor Central da Mata Atlântica no Estado da Bahia, com o objetivo de identificar e analisar seu atual nível de implementação. Foi utilizada, com as devidas adaptações, a metodologia de Lemos de Sá e Ferreira (2000), a qual consiste na aplicação de uma escala de padrão, onde a variação de análise do nível de implementação obedece a um intervalo entre 0 a 5 pontos. Após obter os dados do nível de implementação foi utilizado o método de agregação de Ward para auxiliar a visualização das unidades de conservação estudadas quanto à dissimilaridade entre elas. Utilizou-se a classificação internacional proposta pela IUCN (International Union for Conservation of Nature) para que as UCs sejam comparáveis com trabalhos realizados em outros países. As UCs avaliadas estão nos grupos Ia, II, V e VI da IUCN. Conforme os resultados, 50% das unidades de conservação analisadas encontram-se razoavelmente implementadas, 40% insuficientemente implementadas, 6,7% apresentam-se como "parques de papel" e apenas 3,3% podem ser classificadas como satisfatoriamente implementadas. Essas áreas enfrentam problemas em sua regularização fundiária; apresentam deficiência em infraestrutura, recursos humanos e financeiros. Diante dos resultados, fica evidente a recorrência do fato de que as unidades de conservação em estudo necessitam ser efetivamente implementadas. Para que isso ocorra, as políticas ambientais devem ser voltadas para ações com objetivos de consolidar essa estratégia de conservação.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We studied the spin-polarized charge densities in II-VI-based diluted magnetic superlattices formed of p-doped ZnTe:Mg/ZnTe:TM/ZnTe:Mg non-magnetic/magnetic/non-magnetic layers, with TM standing for transition metal. The calculations were performed within a self-consistent k.p method, in which are also taken into account the exchange correlation effects in the local density approximation. Our results show a limit for the width of the non-magnetic layer for which the difference between the opposite spin charge densities is maximized, indicating the best conditions to obtain full polarization by varying the TM content. We also discuss these effects in the calculated photoluminescence spectra. Our findings point to the possibility of engineering the spin-polarized charge distribution by varying the widths of the magnetic and non-magnetic layers and/or varying the TM concentration in the magnetic layers, thus providing a guide for future experiments. (c) 2012 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study aimed to evaluate, ex vivo, the nanoleakage in dentinal tubules, the linear infiltration of silver nitrate in the dentin wall/root-end filling material interface, and the presence of gaps in this interface in root-end cavities filled with 4 filling materials. Forty-eight disto-buccal root canals of maxillary molars were instrumented and filled. Retrograde cavities were prepared with ultrasonic points (apical 2 mm). The samples were divided into 2 control groups (n = 4) and 4 experimental groups (n = 10): Group I white mineral trioxide aggregate (MTA); Group II Super EBA; Group III Portland cement; and Group IV Sealer 26. After 1 week, the specimens were subjected to silver nitrate and prepared for SEM (backscattered electrons). In the apical-apical segment, an area with significantly higher leakage was observed for Super EBA, followed by Portland cement, MTA, and Sealer 26 (P = 0.0054). In the medium and cervical segments, all materials showed the same leakage behavior (P = 0.1815 and P = 0.1723, respectively). The linear infiltration at the dentin wall/root-end filling material interface was higher with Super EBA than the other groups. No differences in the percentage of gaps along the 3 mm of dentin wall/root-end filling material interface between the 4 materials were evident (P > 0.05). Nanoleakage occurred mainly in the apical segment of the samples, and Super EBA showed the highest values. The area and linear leakage were lower in the middle and coronal segments, regardless of the root-end filling material. No material perfectly sealed the root-end cavities, which allowed for the leakage occurrence. Microsc. Res. Tech. 75:796800, 2012. (C) 2011 Wiley Periodicals, Inc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The mixed ruthenium(II) complexes trans-[RuCl(2)(PPh(3))(2)(bipy)] (1), trans-[RuCl(2)(PPh(3))(2)(Me(2)bipy)](2), cis-[RuCl(2)(dcype)(bipy)](3), cis-[RuCl(2)(dcype)(Me(2)bipy)](4) (PPh(3) = triphenylphosphine, dcype = 1,2-bis(dicyclohexylphosphino)ethane, bipy = 2,2'-bipyridine, Me(2)bipy = 4,4'-dimethyl-2,2'-bipyridine) were used as precursors to synthesize the associated vinylidene complexes. The complexes [RuCl(=C=CHPh)(PPh(3))(2)(bipy)]PF(6) (5), [RuCl(=C=CHPh)(PPh(3))(2)(Me(2)bipy)]PF(6) (6), [RuCl(=C=CHPh)(dcype)(bipy)]PF(6) (7), [RuCl(=C=CHPh)(dcype)(bipy)]PF(6) (8) were characterized and their spectral, electrochemical, photochemical and photophysical properties were examined. The emission assigned to the pi-pi* excited state from the vinylidene ligand is irradiation wavelength (340, 400, 430 nm) and solvent (CH(2)Cl(2), CH(3)CN, EtOH/MeOH) dependent. The cyclic voltammograms of (6) and (7) show a reversible metal oxidation peak and two successive ligand reductions in the +1.5-(-0.64) V range. The reduction of the vinylidene leads to the formation of the acetylide complex, but due the hydrogen abstraction the process is irreversible. The studies described here suggest that for practical applications such as functional materials, nonlinear optics, building blocks and supramolecular photochemistry. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction The primary end points of randomized clinical trials evaluating the outcome of therapeutic strategies for coronary artery disease (CAD) have included nonfatal acute myocardial infarction, the need for further revascularization, and overall mortality. Noncardiac causes of death may distort the interpretation of the long-term effects of coronary revascularization. Materials and methods This post-hoc analysis of the second Medicine, Angioplasty, or Surgery Study evaluates the cause of mortality of patients with multivessel CAD undergoing medical treatment, percutaneous coronary intervention, or surgical myocardial revascularization [coronary artery bypass graft surgery (CABG)] after a 6-year follow-up. Mortality was classified as cardiac and noncardiac death, and the causes of noncardiac death were reported. Results Patients were randomized into CABG and non-CABG groups (percutaneous coronary intervention plus medical treatment). No statistical differences were observed in overall mortality (P = 0.824). A significant difference in the distribution of causes of mortality was observed among the CABG and non-CABG groups (P = 0.003). In the CABG group, of the 203 randomized patients, the overall number of deaths was 34. Sixteen patients (47.1%) died of cardiac causes and 18 patients (52.9%) died of noncardiac causes. Of these, seven deaths (20.6%) were due to neoplasia. In the non-CABG group, comprising 408 patients, the overall number of deaths was 69. Fifty-three patients (77%) died of cardiac causes and 16 patients (23%) died of noncardiac causes. Only five deaths (7.2%) were due to neoplasia. Conclusion Different treatment options for multivessel coronary artery disease have similar overall mortality: CABG patients had the lowest incidence of cardiac death, but the highest incidence of noncardiac causes of death, and specifically a higher tendency toward cancer-related deaths. Coron Artery Dis 23:79-84 (C) 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Several types of alumina were synthesized from sodium aluminate (NaAlO2) by precipitation with sulfuric acid (H2SO4) and subsequently calcination at 500 degrees C to obtain gamma-Al2O3. The precursor aluminate was derived from aluminum scrap. The various gamma-Al2O3 synthesized were characterized by Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), adsorption-desorption of N-2 (S-BET) and scanning electron microscopy (SEM). XRD revealed that distinct phases of Al2O3 were formed during thermal treatment. Moreover, it was observed that conditions of synthesis (pH, aging time and temperature) strongly affect the physicochemical properties of the alumina. A high-surface-area alumina (371 m(2) g(-1)) was synthesized under mild conditions, from inexpensive raw materials. These aluminas were tested for the adsorption of Cd(II), Zn(II) and Pb(II) from aqueous solution at toxic metal concentrations, and isotherms were determined. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the present paper, we report on the molecular interaction and photochemistry of TiO2 nanoparticles (NPs) and cytochrome c systems for understanding the effects of supramolecular organization and electron transfer by using two TiO2 structures: P25 TiO2 NPs and titanate nanotubes. The adsorption and reduction of cytochrome c heme iron promoted by photo-excited TiO2, arranged as P25 TiO2 NPs and as nanotubes, were characterized using electronic absorption spectroscopy, thermogravimetric analysis, and atomic force microscopy. In an aqueous buffered suspension (pH 8.0), the mass of cytochrome c adsorbed on the P25 TiO2 NP surface was 2.3 fold lower (0.75 mu g m(-2)) than that adsorbed on the titanate nanotubes (1.75 mu g m(-2)). Probably due to the high coverage of titanate nanotubes by adsorbed cytochrome c, the low amount of soluble remaining protein was not as efficiently photo-reduced by this nanostructure as it was by the P25 TiO2 NPs. Cytochrome c, which desorbed from both titanium materials, did not exhibit changes in its redox properties. In the presence of the TiO2 NPs, the photo-induced electron transfer from water to soluble cytochrome c heme iron was corroborated by the following findings: (i) identification by EPR of the hydroxyl radical production during the irradiation of an aqueous suspension of TiO2 NPs, (ii) impairment of a cytochrome c reduction by photo-excited TiO2 in the presence of dioxane, which affects the dielectric constant of the water, and (iii) change in the rate of TiO2-promoted cytochrome c reduction when water was replaced with D2O. The TiO2-promoted photo-reduction of cytochrome c was reverted by peroxides. Cytochrome c incorporated in the titanate nanotubes was also reversibly reduced under irradiation, as confirmed by EPR and UV-visible spectroscopy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The electronic interactions between the [Cu(opba)]2- anions (where opba is orthophenylenebis (oxamato)) and single-wall carbon nanotubes (SWCNTs) were investigated by resonance Raman spectroscopy. The opba can form molecular magnets, and the interactions of opba with SWCNTs can produce materials with very different magnetic/electronic properties. It is observed that the electronic interaction shows a dependence on the SWCNT diameter independent of whether they are metallic or semiconducting, although the interaction is stronger for metallic tubes. The interaction also is dependent on the amount of complex that is probably adsorbed on the carbon surface of the SWCNTs. Some charge transfer can be also occurring between the metallic complex and the SWCNTs. Copyright (c) 2012 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To evaluate the dentoskeletal changes of Class II malocclusion treatment with the Twin Force Bite Corrector (TFBC). Materials and Methods: The sample comprised 86 lateral cephalograms obtained from 43 subjects with Class II division 1 malocclusion; the subjects were divided into two groups. The experimental group comprised 23 patients with a mean initial age of 12.11 years who were treated with the TFBC for a mean period of 2.19 years. The control group included 40 lateral cephalograms from 20 Class II nontreated patients, with an initial mean age of 12.55 years and a mean observation period of 2.19 years. The lateral cephalograms were evaluated before and after orthodontic treatment in group 1 and in the beginning and end of the observation period in group 2. t-Tests were used to compare the initial and final cephalometric characteristics of the groups as well as the amount of change. Results: The experimental group presented greater maxillary growth restriction and mandibular retrusion than the control group, as well as greater maxillomandibular relationship improvement and greater labial tipping of the mandibular incisors. The results also showed a greater decrease in overbite and overjet in the experimental group, and there were no statistically significant differences in the craniofacial growth pattern between groups. Conclusions: The TFBC promotes restriction of anterior maxillary displacement without significant changes in mandibular length and position and improvement of maxillomandibular relationship without changes in facial growth and significant buccal tipping of mandibular incisors. Class II correction with the TFBC occurred primarily as a result of dentoalveolar changes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Chemical disinfectants are usually associated with mechanical methods to remove stains and reduce biofilm formation. This study evaluated the effect of disinfectants on release of metal ions and surface roughness of commercially pure titanium, metal alloys, and heat-polymerized acrylic resin, simulating 180 immersion trials. Disk-shaped specimens were fabricated with commercially pure titanium (Tritan), nickel-chromium-molybdenum-titanium (Vi-Star), nickel-chromium (Fit Cast-SB Plus), and nickel-chromium-beryllium (Fit Cast-V) alloys. Each cast disk was invested in the flasks, incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n=5) were immersed in these solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous, and Polident. Deionized water was used as a control. The quantitative analysis of metal ion release was performed using inductively coupled plasma mass spectrometry (ELAN DRC II). A surface analyzer (Surftest SJ-201P) was used to measure the surface roughness (µm). Data were recorded before and after the immersions and evaluated by two-way ANOVA and Tukey's test (α=0.05). The nickel release proved most significant with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. There was a significant difference in surface roughness of the resin (p=0.011) after immersion. Cepacol caused significantly higher resin roughness. The immersion products had no influence on metal roughness (p=0.388). It could be concluded that the tested alloys can be considered safe for removable denture fabrication, but disinfectant solutions as Cepacol and Medical Interporous tablet for daily denture immersion should be used with caution because it caused greater resin surface roughness and greater ion release, respectively.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the title complex, [Ru(C12H8N2)2(C5H6N2)2](PF6)2, the RuII atom is bonded to two -diimine ligands, viz. 1,10- phenanthroline (phen), in a cis configuration, in addition with with two 4-aminopyridine (4Apy) ligands, resulting in a distorted octahedral coordination geometry. N—H F hydrogen-bonding interactions play an important role in the crystal assembly: 21-screw-axis-related complex molecules and PF6 counter-ions alternate in helical chains formed along the a axis by means of these contacts. N—H contacts (H centroid = 3.45 A ° ) are responsible for cross-linking between the helical chains along [001].