6 resultados para screen printing

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to examine the reliability, validity and classification accuracy of the South Oaks Gambling Screen (SOGS) in a sample of the Brazilian population. Participants in this study were drawn from three sources: 71 men and women from the general population interviewed at a metropolitan train station; 116 men and women encountered at a bingo venue; and 54 men and women undergoing treatment for gambling. The SOGS and a DSM-IV-based instrument were applied by trained researchers. The internal consistency of the SOGS was 0.75 according to the Cronbach`s alpha model, and construct validity was good. A significant difference among groups was demonstrated by ANOVA (F ((2.238)) = 221.3, P < 0.001). The SOGS items and DSM-IV symptoms were highly correlated (r = 0.854, P < 0.01). The SOGS also presented satisfactory psychometric properties: sensitivity (100), specificity (74.7), positive predictive rate (60.7), negative predictive rate (100) and misclassification rate (0.18). However, a cut-off score of eight improved classification accuracy and reduced the rate of false positives: sensitivity (95.4), specificity (89.8), positive predictive rate (78.5), negative predictive rate (98) and misclassification rate (0.09). Thus, the SOGS was found to be reliable and valid in the Brazilian population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: to determine the ability of the reduced form of a screening instrument, the Patient Health Questionnaire-2 (PHQ-2), to assess the presence of depressive disorders in patients admitted to a general hospital. Method: A sample of 227 patients admitted to the clinical wards of a Brazilian general university hospital were assessed with Module A of the Diagnostic Structured Interview for the DSM-IV (SCID-IV) and filled out the PHQ-9 and PHQ-2. Results: The PHQ-2 demonstrated an area under the ROC curve of 0.89 (p < 0.0001), with a cutoff point of three or more being the one that best equilibrated the sensitivity (0.86) and specificity (0.75) values. The agreement index between the PHQ-2 and module A of SCID-W was 78.4% and the Kappa value was 0.51. Regarding reliability, the Cronbach alpha value obtained was 0.64 and the intraclass correlation coefficient was 0.52. Conclusion: PHQ-2 proved to be an instrument with good psychometric properties comparable to those of PHQ-9, being superior to the latter regarding the rate of false-positive results. In addition, it is a brief instrument that elicits little resistance on the part of the patient, being inexpensive and requiring little time, thus being of important help to the treatment teams for the detection of depressive disorder, being suitable for incorporation into hospital admission protocols and thus possibly favoring more immediate interventions. (Int'l J. Psychiatry in Medicine 2012;44:141-148)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and fast-responding membrane-free amperometric gas sensor is described, consisting of a small filter paper foil soaked with a room temperature ionic liquid (RTIL), upon which three electrodes are screen printed with carbon ink, using a suitable mask. It takes advantage of the high electrical conductivity and negligible vapour pressure of RTILs as well as their easy immobilization into a porous and inexpensive supporting material such as paper. Moreover, thanks to a careful control of the preparation procedure, a very close contact between the RTIL and electrode material can be achieved so as to allow gaseous analytes to undergo charge transfer just as soon as they reach the three-phase sites where the electrode material, paper supported RTIL and gas phase meet. Thus, the adverse effect on recorded currents of slow steps such as analyte diffusion and dissolution in a solvent is avoided. To evaluate the performance of this device, it was used as a wall-jet amperometric detector for flow injection analysis of 1-butanethiol vapours, adopted as the model gaseous analyte, present in headspace samples in equilibrium with aqueous solutions at controlled concentrations. With this purpose, the RTIL soaked paper electrochemical detector (RTIL-PED) was assembled by using 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl) imide as the wicking RTIL and printing the working electrode with carbon ink doped with cobalt(II) phthalocyanine, to profit from its ability to electrocatalyze thiol oxidation. The results obtained were quite satisfactory (detection limit: 0.5 mu M; dynamic range: 2-200 mu M, both referring to solution concentrations; correlation coefficient: 0.998; repeatability: +/- 7% RSD; long-term stability: 9%), thus suggesting the possible use of this device for manifold applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The congenital transmission of Trypanosoma cruzi has gained epidemiological importance because it is partially responsible for the spread of Chagas disease worldwide. The feasibility of a cure when infected children are treated early makes the detection of congenital infection a valuable goal toward the control of the disease. Here, the authors review and discuss the findings of Bua et al., who quantified the parasitemia of infected women and their newborns by quantitative PCR. The authors demonstrate that the maternal parasite burden is directly related to the risk of neonatal infection. This study points out the importance of a quantitative screen for T. cruzi in pregnant women who live in, or have traveled to, endemic areas for improving the diagnosis of infected newborns and providing prompt treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Calstabins 1 and 2 bind to Ryanodine receptors regulating muscle excitation-contraction coupling. Mutations in Ryanodine receptors affecting their interaction with calstabins lead to different cardiac pathologies. Animal studies suggest the involvement of calstabins with dilated cardiomyopathy. Results We tested the hypothesis that calstabins mutations may cause dilated cardiomyopathy in humans screening 186 patients with idiopathic dilated cardiomyopathy for genetic alterations in calstabins 1 and 2 genes (FKBP12 and FKBP12.6). No missense variant was found. Five no-coding variations were found but not related to the disease. Conclusions These data corroborate other studies suggesting that mutations in FKBP12 and FKBP12.6 genes are not commonly related to cardiac diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The frequent occurrence of inconclusive serology in blood banks and the absence of a gold standard test for Chagas'disease led us to examine the efficacy of the blood culture test and five commercial tests (ELISA, IIF, HAI, c-ELISA, rec-ELISA) used in screening blood donors for Chagas disease, as well as to investigate the prevalence of Trypanosoma cruzi infection among donors with inconclusive serology screening in respect to some epidemiological variables. METHODS: To obtain estimates of interest we considered a Bayesian latent class model with inclusion of covariates from the logit link. RESULTS: A better performance was observed with some categories of epidemiological variables. In addition, all pairs of tests (excluding the blood culture test) presented as good alternatives for both screening (sensitivity > 99.96% in parallel testing) and for confirmation (specificity > 99.93% in serial testing) of Chagas disease. The prevalence of 13.30% observed in the stratum of donors with inconclusive serology, means that probably most of these are non-reactive serology. In addition, depending on the level of specific epidemiological variables, the absence of infection can be predicted with a probability of 100% in this group from the pairs of tests using parallel testing. CONCLUSION: The epidemiological variables can lead to improved test results and thus assist in the clarification of inconclusive serology screening results. Moreover, all combinations of pairs using the five commercial tests are good alternatives to confirm results.