2 resultados para protocolos de sincronização

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo do presente estudo foi comparar o sinal eletromiográfi co, a frequência e a amplitude de passada entre diferentes intensidades de corrida: 60%, 80% e 100% da velocidade máxima em dois protocolos incrementais. Participaram deste estudo 11 corredores do sexo masculino. Os protocolos de corrida foram realizados com velocidades iniciais de 10 km.hr-1, com incrementos de 1 km.hr-1 a cada três minutos até a exaustão, que diferiram em relação ao intervalo entre cada estágio incremental: 30 e 120 segundos. Foram analisados valores RMS dos músculos iliocostal lombar, reto femoral, vasto lateral, vasto medial, bíceps femoral, tibial anterior, e gastrocnêmio, e a amplitude e frequência de passada. Os valores RMS mostraram aumento entre as intensidades para quase todos os músculos, e não foram influenciados pelo tipo de protocolo utilizado para maioria dos músculos. A frequência e amplitude de passada apresentaram contribuições percentuais diferenciadas para o aumento da velocidade de corrida.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Few data on the definition of simple robust parameters to predict image noise in cardiac computed tomography (CT) exist. Objectives: To evaluate the value of a simple measure of subcutaneous tissue as a predictor of image noise in cardiac CT. Methods: 86 patients underwent prospective ECG-gated coronary computed tomographic angiography (CTA) and coronary calcium scoring (CAC) with 120 kV and 150 mA. The image quality was objectively measured by the image noise in the aorta in the cardiac CTA, and low noise was defined as noise < 30HU. The chest anteroposterior diameter and lateral width, the image noise in the aorta and the skin-sternum (SS) thickness were measured as predictors of cardiac CTA noise. The association of the predictors and image noise was performed by using Pearson correlation. Results: The mean radiation dose was 3.5 ± 1.5 mSv. The mean image noise in CT was 36.3 ± 8.5 HU, and the mean image noise in non-contrast scan was 17.7 ± 4.4 HU. All predictors were independently associated with cardiac CTA noise. The best predictors were SS thickness, with a correlation of 0.70 (p < 0.001), and noise in the non-contrast images, with a correlation of 0.73 (p < 0.001). When evaluating the ability to predict low image noise, the areas under the ROC curve for the non-contrast noise and for the SS thickness were 0.837 and 0.864, respectively. Conclusion: Both SS thickness and CAC noise are simple accurate predictors of cardiac CTA image noise. Those parameters can be incorporated in standard CT protocols to adequately adjust radiation exposure.