3 resultados para projet portable

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Obstructive sleep apnea (OSA) is common among patients with coronary artery disease. However, OSA remains largely under recognized. The lack of clinical suspicion and difficulties to access full polysomnography (PSG) are limiting factors. The aim of this study was to evaluate, among patients referred to coronary artery bypass grafting (CABG): (i) the prevalence of OSA, (ii) the association of OSA with clinical symptoms, (iii) the performance of overnight unattended portable monitoring (PM) as an alternative method for the diagnosis of OSA. Methods Consecutive patients referred for CABG were evaluated by standard physical evaluation and validated questionnaires (Berlin questionnaire and Epworth Sleepiness Scale) and underwent full PSG and PM (Stardust II). Results We studied 70 consecutive patients (76% men), age 58 +/- 7 years (mean +/- SD), BMI [median (interquartile range)] 27.6 kg/m(2) (25.8-31.1). The prevalence of OSA (full PSG) using an apnea-hypopnea index of at least 5 events/h was 87%. Commonly used clinical traits for the screening of OSA such as the Epworth Sleepiness Scale and neck circumference had low sensitivities to detect OSA. In contrast, the Berlin questionnaire showed a good sensitivity (72%) to detect OSA. PM showed good sensitivity (92%) and specificity (67%) for the diagnosis of OSA. Conclusion OSA is strikingly common among patients referred for CABG. The Berlin questionnaire, but not symptom of excessive daytime sleepiness is a useful tool to screen OSA. PM is useful for the diagnosis of OSA and therefore is an attractive tool for widespread use among patients with coronary artery disease. Coron Artery Dis 23:31-38 (C) 2011 Wolters Kluwer Health | Lippincott Williams & Wilkins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 20% Pt3Sn/C catalyst was prepared by reduction with formic acid and used in a direct ethanol fuel cell at low temperatures. The electro-catalytic activity of this bimetallic catalyst was compared to that of a commercial 20% Pt/C catalyst. The PtSn catalyst showed better results in the investigated temperature range (30 degrees-70 degrees C). Generally, Sn promotes ethanol oxidation by adsorption of OH species at considerably lower potentials compared to Pt, allowing the occurrence of a bifunctional mechanism. The bimetallic catalyst was physico-chemically characterized by X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) analyses. The presence of SnO2 in the bulk and surface of the catalyst was observed. It appears that SnO2 can enhance the ethanol electro-oxidation activity at low potentials due to the supply of oxygen-containing species for the oxidative removal of CO and CH3CO species adsorbed on adjacent Pt active sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background The authors have developed a small portable device for the objective measurement of the transparency of corneas stored in preservative medium, for use by eye banks in evaluation prior to transplantation. Methods The optical system consists of a white light, lenses, and pinholes that collimate the white light beams and illuminate the cornea in its preservative medium, and an optical filter (400–700 nm) that selects the range of the wavelength of interest. A sensor detects the light that passes through the cornea, and the average corneal transparency is displayed. In order to obtain only the tissue transparency, an electronic circuit was built to detect a baseline input of the preservative medium prior to the measurement of corneal transparency. The operation of the system involves three steps: adjusting the "0 %" transmittance of the instrument, determining the "100 %" transmittance of the system, and finally measuring the transparency of the preserved cornea inside the storage medium. Results Fifty selected corneas were evaluated. Each cornea was submitted to three evaluation methods: subjective classification of transparency through a slit lamp, quantification of the transmittance of light using a corneal spectrophotometer previously developed, and measurement of transparency with the portable device. Conclusion By comparing the three methods and using the expertise of eye bank trained personnel, a table for quantifying corneal transparency with the new device has been developed. The correlation factor between the corneal spectrophotometer and the new device is 0,99813, leading to a system that is able to standardize transparency measurements of preserved corneas, which is currently done subjectively.