5 resultados para positional fault

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes an evolutionary computing strategy to solve the problem of fault indicator (FI) placement in primary distribution feeders. More specifically, a genetic algorithm (GA) is employed to search for an efficient configuration of FIs, located at the best positions on the main feeder of a real-life distribution system. Thus, the problem is modeled as one of optimization, aimed at improving the distribution reliability indices, while, at the same time, finding the least expensive solution. Based on actual data, the results confirm the efficiency of the GA approach to the FI placement problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Obstructive sleep apnea is frequent during the acute phase of stroke, and it is associated with poorer outcomes. A well-established relationship between supine sleep and obstructive sleep apnea severity exists in non-stroke patients. This study investigated the frequency of supine sleep and positional obstructive sleep apnea in patients with ischemic or hemorrhagic stroke. METHODS: Patients who suffered their first acute stroke, either ischemic or hemorrhagic, were subjected to a full polysomnography, including the continuous monitoring of sleep positions, during the first night after symptom onset. Obstructive sleep apnea severity was measured using the apnea-hypopnea index, and the NIHSS measured stroke severity. RESULTS: We prospectively studied 66 stroke patients. The mean age was 57.6+/-11.5 years, and the mean body mass index was 26.5+/-4.9. Obstructive sleep apnea (apnea-hypopnea index >= 5) was present in 78.8% of patients, and the mean apnea-hypopnea index was 29.7+/-26.6. The majority of subjects (66.7%) spent the entire sleep time in a supine position, and positional obstructive sleep apnea was clearly present in the other 23.1% of cases. A positive correlation was observed between the NIHSS and sleep time in the supine position (r(s) = 0.5; p<0.001). CONCLUSIONS: Prolonged supine positioning during sleep was highly frequent after stroke, and it was related to stroke severity. Positional sleep apnea was observed in one quarter of stroke patients, which was likely underestimated during the acute phase of stroke. The adequate positioning of patients during sleep during the acute phase of stroke may decrease obstructive respiratory events, regardless of the stroke subtype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To evaluate the effectiveness of a canalith-repositioning procedure in postural control of older patients with idiopathic benign paroxysmal positional vertigo (BPPV). Study Design. Prospective clinical trial. Setting. A tertiary referral center. Methods. A 9-month follow-up survey with a prospective design was conducted among 33 older patients with BPPV. Patients underwent static posturography (Balance Rehabilitation Unit [BRU]) and were administered the Dizziness Handicap Inventory (DHI) before and after the maneuver. After the treatment, they were compared with 33 healthy older subjects. The posturography parameters were the limit of stability (LOS), the center of body-pressure area (COP), and the velocity of oscillation (VOS) under conditions of visual, somatosensory, and visual-vestibular conflict. Results. One canalith-repositioning procedure relieved most patients' complaints (54.5%), and 100% were relieved with 1 to 3 maneuvers. Total DHI score and all subscales improved after treatment (P < .01). The LOS values pretreatment (mean [SD] 134.27 [55.32] cm(2)) and posttreatment (181.03 [47.79] cm(2)) were significantly different (P < .01). Comparative analysis of COP values showed a relevant statistical difference in 8 of 10 postmaneuver conditions (P < .01). The postmaneuver VOS showed a significant difference under 7 conflict conditions. There were no differences between the healthy older subjects and treated patients for all VOS values under all conditions and for COP values under 9 conditions. Conclusion. The canalith-repositioning procedure promotes remission of symptoms, an increase in LOS, and improvement in postural control under conditions of somatosensory and visual conflict and visual-vestibular interaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article we propose an efficient and accurate method for fault location in underground distribution systems by means of an Optimum-Path Forest (OPF) classifier. We applied the time domains reflectometry method for signal acquisition, which was further analyzed by OPF and several other well-known pattern recognition techniques. The results indicated that OPF and support vector machines outperformed artificial neural networks and a Bayesian classifier, but OPF was much more efficient than all classifiers for training, and the second fastest for classification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Network reconfiguration for service restoration (SR) in distribution systems is a complex optimization problem. For large-scale distribution systems, it is computationally hard to find adequate SR plans in real time since the problem is combinatorial and non-linear, involving several constraints and objectives. Two Multi-Objective Evolutionary Algorithms that use Node-Depth Encoding (NDE) have proved able to efficiently generate adequate SR plans for large distribution systems: (i) one of them is the hybridization of the Non-Dominated Sorting Genetic Algorithm-II (NSGA-II) with NDE, named NSGA-N; (ii) the other is a Multi-Objective Evolutionary Algorithm based on subpopulation tables that uses NDE, named MEAN. Further challenges are faced now, i.e. the design of SR plans for larger systems as good as those for relatively smaller ones and for multiple faults as good as those for one fault (single fault). In order to tackle both challenges, this paper proposes a method that results from the combination of NSGA-N, MEAN and a new heuristic. Such a heuristic focuses on the application of NDE operators to alarming network zones according to technical constraints. The method generates similar quality SR plans in distribution systems of significantly different sizes (from 3860 to 30,880 buses). Moreover, the number of switching operations required to implement the SR plans generated by the proposed method increases in a moderate way with the number of faults.