8 resultados para pin-on-disc wear test

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reduction of friction and wear in systems presenting metal-to-metal contacts, as in several mechanical components, represents a traditional challenge in tribology. In this context, this work presents a computational study based on the linear Archard's wear law and finite element modeling (FEM), in order to analyze unlubricated sliding wear observed in typical pin on disc tests. Such modeling was developed using finite element software Abaqus® with 3-D deformable geometries and elastic–plastic material behavior for the contact surfaces. Archard's wear model was implemented into a FORTRAN user subroutine (UMESHMOTION) in order to describe sliding wear. Modeling of debris and oxide formation mechanisms was taken into account by the use of a global wear coefficient obtained from experimental measurements. Such implementation considers an incremental computation for surface wear based on the nodal displacements by means of adaptive mesh tools that rearrange local nodal positions. In this way, the worn track was obtained and new surface profile is integrated for mass loss assessments. This work also presents experimental pin on disc tests with AISI 4140 pins on rotating AISI H13 discs with normal loads of 10, 35, 70 and 140 N, which represent, respectively, mild, transition and severe wear regimes, at sliding speed of 0.1 m/s. Numerical and experimental results were compared in terms of wear rate and friction coefficient. Furthermore, in the numerical simulation the stress field distribution and changes in the surface profile across the worn track of the disc were analyzed. The applied numerical formulation has shown to be more appropriate to predict mild wear regime than severe regime, especially due to the shorter running-in period observed in lower loads that characterizes this kind of regime.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a ball-on-disc wear test, an alumina ceramic body sliding against a silicon nitride ceramic body in water achieved an ultra-low friction coefficient (ULFC) of 0.004. The profilometer and EDX measurements indicated that the ULFC regime in this unmated Al2O3-Si3N4 pair was achieved because of the formation of a flat and smooth interface of nanometric roughness, which favored the hydrodynamic lubrication. The triboreactions formed silicon and aluminum hydroxides which contributed to decrease roughness and shear stress at the contact interface. This behavior enables the development of low energy loss water-based tribological systems using oxide ceramics. 13 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The identification of color vision types in primates is fundamental to understanding the evolution and biological function of color perception. The Hard, Randy, and Rittler (HRR) pseudoisochromatic test categorizes human color vision types successfully. Here we provide an experimental setup to employ HRR in a nonhuman primate, the capuchin (Cebus libidinosus), a platyrrhine with polymorphic color vision. The HRR test consists of plates with a matrix composed of gray circles that vary in size and brightness. Differently colored circles form a geometric shape (X, O, or Delta) that is discriminated visually from the gray background pattern. The ability to identify these shapes determines the type of dyschromatopsy (deficiency in color vision). We tested six capuchins in their own cages under natural sunlight. The subjects chose between two HRR plates in each trial: one with the gray pattern only and the other with a colored shape, presented on the left or right side at random. We presented the test 40 times and calculated the 95 % confidence limits for chance performance based on the binomial test. We also genotyped all subjects for exons 3 and 5 of the X-linked opsin genes. The HRR test diagnosed two subjects as protan dichromats (missing or defective L-cone), three as deutan dichromats (missing or defective M-cone), and one female as trichromat. Genetic analysis supported the behavioral data for all subjects. These findings show that the HRR test can be applied to diagnose color vision in nonhuman primates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study aimed to investigate the antimicrobial properties and cytotoxicity of the monomer methacryloyloxyundecylpyridinium bromide (MUPB), an antiseptic agent capable of copolymerizing with denture base acrylic resins. Materials and Methods: The antimicrobial activity of MUPB was tested against the species Candida albicans, Candida dubliniensis, Candida glabrata, Lactobacillus casei, Staphylococcus aureus, and Streptococcus mutans. The minimum inhibitory and fungicidal/bactericidal concentrations (MIC, MFC/MBC) of MUPB were determined by serial dilutions in comparison with cetylpyridinium chloride (CPC). The cytotoxic effects of MUPB at concentrations ranging from 0.01 to 1 g/L were assessed by MTT test on L929 cells and compared with methyl methacrylate (MMA). The antimicrobial activity of copolymerized MUPB was tested by means of acrylic resin specimens containing three concentrations of the monomer (0, 0.3, 0.6% w/w). Activity was quantified by means of a disc diffusion test and a quantification of adhered planktonic cells. Statistical analysis employed the Mann-Whitney test for MIC and MFC/MBC, and ANOVA for the microbial adherence test (a= 0.05). Results: MUBP presented lower MIC values when compared with CPC, although differences were significant for C. dubliniensis and S. mutans only (p= 0.046 and 0.043, respectively). MFC/MBC values were similar for all species except C. albicans; in that case, MUPB presented significantly higher values (p= 0.046). MUPB presented higher cytotoxicity than MMA for all tested concentrations (p < 0.001) except at 0.01 g/L. Irrespective of the concentration incorporated and species, there was no inhibition halo around the specimens. The incorporation of MUPB influenced the adhesion of C. albicans only (p= 0.003), with lower CFU counts for the 0.6% group. Conclusions: It was concluded that non-polymerized MUPB has an antimicrobial capacity close to that of CPC and high cytotoxicity when compared with MMA. The antimicrobial activity of MUPB after incorporation within a denture base acrylic resin did not depend on its elution, but was shown to be restricted to C. albicans.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to evaluate the genetic differences among three matrix groups of Cedrela fissilis based on quantitative juvenile variables on a progeny test to define seed collecting zones and use of seeds of this species in the study region as well as to evaluate genetic variability of the sampled material. A progeny test was established in a nursery with seeds from 48 seed trees collected in the municipalities of Rio Negrinho, Mafra and Sao Bento do Sul, state of Santa Catarina, and in the municipalities of Lapa, Rio Negro, Campo do Tenente and Antonio Olinto, state of Parana. Of the collected seed trees, 33 sampled trees were distributed in three sites and 15 trees were dispersed in the studied region. It was used a complete random block design, with 8 replicates and 20 plants per plot. Evaluated data included: emergency rate; seedling base diameter and height (61, 102 and 145 days after the seeds were sowed); seedling survival; number of leaves per seedling; aerial section dry mass and root dry mass; and the foliar area of the third fully expanded leaf measured from the apical meristem. The Maximum Restricted Likelihood Method (REML) was used, using the software SELEGEN for analysis. It was found that the juvenile characters are strongly genetically controlled and they can be used to estimate genetic variability of population samples of Cedrela fissilis. The three groups of trees spatially limited did not significantly differ among each other, allowing to conclude that the three areas are part of the same tree seed transfer zone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Justificativa e objetivos: As ligas acadêmicas vêm se firmando como instrumentos de ensino médico e inserção dos estudantes de medicina na prática das especialidades, inclusive na anestesiologia. Como o papel das ligas no processo de desenvolvimento de competências e aprendizado de seus alunos não é bem conhecido, avaliou-se o aprendizado dos integrantes de uma liga acadêmica de anestesiologia após um ano de participação nas suas atividades. MÉTODO: Os alunos de uma liga acadêmica de anestesiologia foram acompanhados de março a dezembro de 2010 e avaliados por meio de testes cognitivos objetivos de múltipla escolha aplicados antes do início das atividades e após sua conclusão. A frequência nas atividades e o perfil epidemiológico dos alunos foram correlacionados aos resultados dos testes. RESULTADOS: Foram analisados 20 acadêmicos do 3º ao 6º ano, com média de idade de 22,8 (21-26) anos. A frequência média nas atividades propostas foi 10,4/13 (80%). A média de acertos no primeiro teste foi 8,1/17 (47,6%), sendo que os alunos do 3º ano apresentam notas menores (p < 0,02) em relação aos demais. No teste pós-liga, a média de acertos foi 11,9/17 (70%), mostrando melhora no desempenho dos alunos (p < 0,05), e não houve diferença entre as notas dos diferentes anos da graduação. Foi encontrada relação forte entre frequência nas atividades e melhora nas notas (r = 0,719; p < 0,001). CONCLUSÕES: Os alunos que participaram da liga apresentaram melhora nos testes de avaliação de conhecimento, sugerindo que a liga é útil instrumento de ensino e promove ganho de aprendizado em anestesiologia. As atividades desenvolvidas nas ligas podem ter papel positivo na formação acadêmica dos graduandos, destacando-se, neste artigo, a anestesiologia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the prevalence of risk factors for cardiovascular disease in Japanese-Brazilian subjects. SUBJECTS AND METHODS: One hundred thirty-one residents of the Mombuca community were studied. Statistical analysis was based on the X² test, Fisher's Exact test, Student's t test, and ANOVA, at a 5% significance level. RESULTS: The average age was 56.7 years-old; 76.3% had dyslipidemia, 24.4% pre-diabetes (PDM), 10.7% type 2 diabetes mellitus (T2DM), 46.6% hypertension, 52.7% abdominal obesity, and 35.8% metabolic syndrome (MS). There were significant correlations between HOMA-IR and MS diagnosis and obesity, while HOMA-β levels were decreased in T2DM and PDM. The ankle-brachial index was positive for peripheral artery disease in 22.3% of the individuals. Electrocardiograms did not show increased evidence of myocardial ischemia. CONCLUSION: Subjects of this community are exposed to major cardiovascular risk factors, namely high prevalence of MS diagnoses and increased HOMA-IR. Arq Bras Endocrinol Metab. 2012;56(9):608-13

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Objectives: Nanofilled composite resins are claimed to provide superior mechanical properties compared with microhybrid resins. Thus, the aim of this study was to compare nanofilled with microhybrid composite resins. The null hypothesis was that the size and the distribution of fillers do not influence the mechanical properties of surface roughness and wear after simulated toothbrushing test. Material and methods: Ten rectangular specimens (15 mm x 5 mm x 4 mm) of Filtek Z250 (FZ2), Admira (A), TPH3 (T), Esthet-X (EX), Estelite Sigma (ES), Concept Advanced (C), Grandio (G) and Filtek Z350 (F) were prepared according to manufacturer's instructions. Half of each top surface was protected with nail polish as control surface (not brushed) while the other half was assessed with five random readings using a roughness tester (Ra). Following, the specimens were abraded by simulated toothbrushing with soft toothbrushes and slurry comprised of 2: 1 water and dentifrice (w/w). 100,000 strokes were performed and the brushed surfaces were re-analyzed. Nail polish layers were removed from the specimens so that the roughness (Ra) and the wear could be assessed with three random readings (mu m). Data were analyzed by ANOVA and Tukey's multiple-comparison test (alpha = 0.05). Results: Overall outcomes indicated that composite resins showed a significant increase in roughness after simulated toothbrushing, except for Grandio, which presented a smoother surface. Generally, wear of nanofilled resins was significantly lower compared with microhybrid resins. Conclusions: As restorative materials suffer alterations under mechanical challenges, such as toothbrushing, the use of nanofilled materials seem to be more resistant than microhybrid composite resins, being less prone to be rougher and worn.