8 resultados para phacoemulsification

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the incidence of Piry virus contamination among surgical instruments used with disposable accessories for phacoemulsification during sequential surgeries. Methods: An experimental model was created with 4 pigs' eyes that were contaminated with Piry virus and 4 pigs' eyes that were not contaminated. Phacoemulsification was performed on the eyes, alternating between the contaminated and non-contaminated eyes. From one surgery to another, the operating fields, gloves, scalpel, tweezers, needles, syringes, tips and bag collector from the phacoemulsification machine were exchanged; only the hand piece and the irrigation and aspiration systems were maintained. Results: In the collector bag, three samples from the contaminated eyes (3/4) were positive, and two samples from the non-contaminated (2/4) eyes were also positive; at the tip, one sample from the contaminated eyes (1/4) and two samples of the noncontaminated eyes (2/4) yielded positive results. In the irrigation system, one sample from a non-contaminated eye (1/4) was positive, and in the aspiration system, two samples from contaminated eyes (2/4) and two samples from non-contaminated eyes (2/4) were positive. In the gloves, the samples were positive in two samples from the non-contaminated eyes (2/4) and in two samples from the contaminated eyes (2/4). In the scalpel samples, three contaminated eyes (3/4) and none of the non-contaminated eyes (0/4) were positive; finally, two samples from the anterior chambers of the non-contaminated eyes gathered after surgery were positive. Conclusions: In two non-contaminated eyes, the presence of genetic material was detected after phacoemulsification surgery, demonstrating that the transmission of the genetic material of the Piry virus occurred at some point during the surgery on these non-contaminated eyes when the hand piece and irrigation and aspiration systems were reused between surgeries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study sought to compare the effects and outcomes of two ophthalmic viscosurgical devices, 1.6% hyaluronic acid/4.0% chondroitin sulfate and 2.0% hydroxypropylmethylcellulose, during phacoemulsification. METHODS: This prospective, randomized clinical trial comprised 78 eyes (39 patients) that received phacoemulsification performed by the same surgeon using a standardized technique. Patients were randomly assigned to receive either 1.6% hyaluronic acid/4.0% chondroitin sulfate or 2.0% hydroxypropylmethylcellulose on the first eye. The other eye was treated later and received the other viscoelastic agent. Preoperative and postoperative examinations (5, 24 and 48 hours; 7 and 14 days; 3 and 6 months) included measurements of the total volume of the ophthalmic viscosurgical device, ultrasound and washout times to completely remove the ophthalmic viscosurgical device, intraocular pressure, central corneal thickness and best-corrected visual acuity. The corneal endothelial cell count was measured at baseline and at six months postoperatively. ClinicalTrials.gov: NCT01387620. RESULTS: There were no statistically significant differences between groups in terms of cataract density or ultrasound time. However, it took longer to remove 2.0% hydroxypropylmethylcellulose than 1.6% hyaluronic acid/ 4.0% chondroitin sulfate, and the amount of viscoelastic material used was greater in the 2.0% hydroxypropylmethylcellulose group. In addition, the best-corrected visual acuity was significantly better in the hyaluronic acid/ chondroitin sulfate group, but this preferable outcome was only observed at 24 hours after the operation. There were no statistically significant differences between the two ophthalmic viscosurgical devices regarding the central corneal thickness or intraocular pressure measurements at any point in time. The corneal endothelial cell count was significantly higher in the hyaluronic acid/chondroitin sulfate group. CONCLUSION: The ophthalmic viscosurgical device consisting of 1.6% hyaluronic acid/4.0% chondroitin sulfate was more efficient during phacoemulsification and was easier to remove after IOL implantation than 2.0% hydroxypropylmethylcellulose. In addition, the corneal endothelial cell count was significantly higher following the use of hyaluronic acid/chondroitin sulfate than with hydroxypropylmethylcellulose, which promoted an improved level of corneal endothelium protection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To analyze emotional reactions related to cataract surgery in two groups of patients (monocular vision - Group 1; binocular vision - Group 2). Methods: A transversal comparative study was performed using a structured questionnaire from a previous exploratory study before cataract surgery. Results: 206 patients were enrolled in the study, 96 individuals in Group 1 (69.3 +/- 10.4 years) and 110 in Group 2 (68.2 +/- 10.2 years). Most patients in group 1 (40.6%) and 22.7% of group 2, reported fear of surgery (p<0.001). The most important causes of fear were: possibility of blindness, ocular complications and death during surgery. The most prevalent feelings among the groups were doubts about good results and nervousness. Conclusion: Patients with monocular vision reported more fear and doubts related to surgical outcomes. Thus, it is necessary that phisycians considers such emotional reactions and invest more time than usual explaining the risks and the benefits of cataract surgery. Ouvir

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate macular thickness and visual acuity changes after 1 intravitreal injection of 0.5-mg ranibizumab during phacoemulsification cataract surgery in eyes with diabetic macular edema refractory to laser treatment. Methods: Eleven eyes of 11 patients with diabetic macular edema refractory to modified Early Treatment Diabetic Retinopathy Study laser therapy received intravitreal during phacoemulsification cataract surgery. Comprehensive ophthalmic evaluation was performed preoperatively and at 1, 4, 8 +/- 1, and 12 +/- 2 weeks postoperatively. Main outcome measures included central subfield thickness and best-corrected Early Treatment Diabetic Retinopathy Study visual acuity. Results: Eleven patients completed the 12-week study visit. Mean central subfield thickness (+/- SEM) was 399.82 +/- 29.50 mu m at baseline and did not change significantly at any postoperative study visit (P > 0.05). Mean (+/- SEM) best-corrected Early Treatment Diabetic Retinopathy Study visual acuity was 0.95 +/- 0.13 logarithm of the minimum angle of resolution (20/200) at baseline and was significantly improved at Weeks 1 (0.38 +/- 0.13), 4 (0.38 +/- 0.11), 8 (0.35 +/- 0.08), and 12 (0.46 +/- 0.12) after treatment (P < 0.05). Conclusion: In this case series of patients with diabetic macular edema refractory to laser therapy, intravitreal ranibizumab administered during cataract surgery was associated with no significant change in central subfield thickness postoperatively. Significant improvement in best-corrected Early Treatment Diabetic Retinopathy Study visual acuity was observed after treatment, likely because of cataract removal. RETINA 32:1799-1803, 2012

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe a technique to rescue the continuous curvilinear capsulorhexis (CCC) in cases in which complete radial tears make it impossible to use normal traction forceps. A circumferential path and rapid movement are applied in the plane of the anterior capsule in the direction of the center pupil. This technique was used in 50 cases. In 47, the CCC could be completed; in 3, it could not and surgery was continued with low-parameter phacoemulsification. No other intraoperative complications occurred.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL) on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes) received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes) received ultraviolet and blue light filter (yellow tinted) IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD]) investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens) difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens) under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Analisar a incidência e causas de cancelamento de cirurgias de catarata em um hospital público de referência. MÉTODOS: Trata-se de um estudo retrospectivo em que foram analisados o número de cancelamentos de facectomias durante o ano de 2009. Foram analisados sexo, idade, tipo de procedimento suspenso (facoemulsificação ou extração extracapsular do cristalino), tipo de anestesia, convênio (Sistema Único de Saúde ou convênio/particular) e motivo de suspensão da cirurgia (causas clínicas, institucionais ou pessoais). RESULTADOS: Foram agendadas no período 2.965 cirurgias de catarata, havendo 650 cancelamentos (21,92%). Dentre as principais razões para a suspensão do procedimento destacaram-se as causas clínicas (86,90%). Os meses de inverno apresentaram os maiores índices de suspensão de cirurgias de catarata. CONCLUSÃO: A taxa de cancelamento de cirurgia de catarata em serviços públicos parece ser a mesma que há 10 anos. A principal causa de suspensão deve-se por condições clínicas (hipertensão, diabetes, falta de exames, etc.).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Comparar custos da cirurgia de catarata em larga escala para um hospital público, para o governo e para a sociedade, pelas técnicas de facoemulsificação (FACO) e extração extracapsular (EECP). MÉTODOS: Foi realizada revisão baseada principalmente em diversos estudos clínicos realizados entre 2002 e 2010, no Centro Cirúrgico Ambulatorial do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. RESULTADOS: Os gastos estimados com os insumos utilizados para as cirurgias foram de R$ 468,92 no grupo FACO e R$ 259,96 no grupo EECP. As despesas hospitalares com o acompanhamento pós-operatório foram em média de R$ 16,40 (42%) menores no grupo FACO. Com relação ao gasto estimado para a Previdência Social, o grupo EECP custou em média, US$ 44,58 por paciente a mais que o grupo FACO. CONCLUSÃO: O incentivo e o investimento governamental para a realização da FACO no SUS são socialmente justificados, deve-se considerar também a economia dos pacientes e do sistema empresarial, bem como as vantagens clínicas para os pacientes e vantagens econômicas para os hospitais.