6 resultados para periods of repeating thickness

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

FALCAI MJ, LOUZADA MJQ, DE PAULA FJA, OKUBO R, VOLPON JB. A modified technique of rat tail suspension for longer periods of observation. Aviat Space Environ Med 2012; 83:1176-80. Background: Rat tail suspension is an accepted method to create experimental osteopenia. However, suspension periods longer than 3 wk may cause tail skin sloughing or rat slippage. The hypothesis was that a traction system with skeletal anchorage through one tail vertebra would prolong the suspension time without significant complications. Methods: There were 80 young adult female Wistar rats that were submitted to one of the following interventions: skeletal tail suspension (N = 20), skin tail suspension (N = 20), no intervention (N = 20), and a baseline control (N = 20). All animals were followed up either for 3 (N = 10) or 6 (N = 10) wk. Animals were assessed for clinical signs of stress and tolerance to suspension. The femur evaluation was in terms of mineral density content, mechanical resistance, and histomorphometry. Results/Discussion: All animals reached the 3-wk end point. However, for the 6-wk period, seven animals suspended by the skin traction method were discarded (70%) because of signs of stress and skin sloughing. In contrast, there was one loss in the skeletal suspension group (10%). All suspended animals developed similar osteopenia at 3 wk characterized by decreased bone mineral content, weakened bone resistance, and loss of femoral mass. At 6 wk, all suspended animals had similar osteopenic parameters, but they were not statistically different from those of the rats in the 3-wk groups. Therefore, suspension longer than 3 wk did not increase the bone deterioration in the femur.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the color stability of composites subjected to different periods of accelerated artificial aging (AAA). A polytetrafluorethylene matrix (10 x 2 mm) was used to fabricate 24 test specimens of three different composites (n=8): Tetric Ceram (Ivoclar/Vivadent); Filtek P90 and Z250 (3M ESPE), shade A3. After light activation for 20 s (FlashLite 1401), polishing and initial color readout (Spectrophotometer PCB 687; BYK Gardner), the test specimens were subjected to AAA (C-UV; Comexim), in 8-h cycles: 4 h exposure to UV-B rays at 50°C and 4 h condensation at 50°C. At the end of each cycle, color readouts were taken and the test ended when the mean value of ΔE attained a level ≥3.30. Tetric Ceram presented alteration in ΔE equal to 3.33 in the first aging cycle. For Filtek P90 and Z250, two (ΔE=3.60) and four (ΔE=3.42) AAA cycles were necessary. After each cycle, there was a reduction of luminosity in all the samples (ΔL). It was concluded that a short period of AAA was sufficient to promote clinically unacceptable color alteration in composites, and that this alteration was material-dependent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The aim of the present study was to evaluate the physicochemical properties of a bioceramic root canal sealer, Endosequence BC Sealer. Radiopacity, pH, release of calcium ions (Ca2+), and flow were analyzed, and the results were compared with AH Plus cement. Methods: Radiopacity and flow were evaluated according to ISO 6876/2001 standards. For the radiopacity analysis, metallic rings with 10-mm diameter and 1-mm thickness were filled with cements. The radiopacity value was determined according to radiographic density (mm Al). The flow test was performed with 0.05 mL of cement placed on a glass plate. A 120-g weight was carefully placed over the cement. The largest and smallest diameters of the disks formed were measured by using a digital caliper. The release of Ca2+ and pH were measured at periods of 3, 24, 72, 168, and 240 hours with spectrophotometer and pH meter, respectively. Data were analyzed by analysis of variance and Tukey test (P < .05). Results: The bioceramic endodontic cement showed radiopacity (3.84 mm Al) significantly lower than that of AH Plus (6.90 mm Al). The pH analysis showed that Endosequence BC Sealer showed pH and release of Ca2+ greater than those of AH Plus (P < .05) during the experimental periods. The flow test revealed that BC Sealer and AH Plus presented flow of 26.96 mm and 21.17 mm, respectively (P < .05). Conclusions: Endosequence BC Sealer showed radiopacity and flow according to ISO 6876/2001 recommendations. The other physicochemical properties analyzed demonstrated favorable values for a root canal sealer. (J Endod 2012;38:842-845)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The research objective was to determine the effects of spacing and seeding density of common bean to the period prior to weed interference (PPI) and weed period prior to economic loss (WEEPPEL). The treatments consisted of periods of coexistence between culture and the weeds, with 0 to 10, 0 to 20, 0 to 30, 0 to 40, 0 to 50, 0 to 60, 0 to 70, and 0 to 80 days and a control maintained without weeds. In addition to the periods of coexistence, there were still studies with an inter-row of 0.45 and 0.60 m, 10 and 15 plants m(-1). The experimental delineation used was randomized blocks with four repetitions per treatment. The grain productivity of the culture had a reduction of 63, 50, 42 and 57% when the coexistence with the weed plants was during the entire cycle of the culture for a row spacing of 0.45 m and a seeding density of 10 and 15 plants per meter; and a row spacing of 0.60m and a seeding density of 10 and 15 plants per meter, respectively. The PPI occurred in 23, 27, 13, and 19 days after crop emergence and WEEPPEL in 10, 9, 8, and 8 days, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Statement of problem. Matrices of unsplinted attachment systems are generally reported to be the weak component of implant overdentures, often requiring frequent maintenance. Clinical wear results in reduced retention of the prosthesis, requiring activation or renewal of the matrix to restore the initial level of retention. Purpose. The purpose of this retrospective study was to measure the wear of the matrix of a ball attachment after various periods of clinical wear. Material and methods. Seventy specimens of 3 groups of matrices of ball attachments that had been in use for mean periods of 12.3 months (1Y group, n=26), 39.0 months (3Y group, n=28) and 95.6 months (8Y group, n=16) were retrieved from 35 patients (2 specimens per patient) and measured on a coordinate measuring machine equipped with a touch trigger probe. Ten unused matrices were used as controls (CTRL group). The external and internal matrix diameters and deviations from circularity were measured. For the various time periods, the decreases in matrix thickness were calculated and compared with controls. Kruskal-Wallis 1-way ANOVA by ranks, followed by the Mann-Whitney post hoc tests, were conducted to test for differences in median values among groups (alpha=.05). Results. For the internal upper diameter of the matrices tested, the Kruskal-Wallis and Mann-Whitney tests revealed significant differences for the 3 groups compared to the controls. For group 1Y, a significant difference (P<.001) of the internal upper diameter was found compared to the CTRL group. Compared to the controls, the nonparametric analyses for groups 3Y and 8Y showed significant differences for the internal upper diameter (P<.001) and deviations from circularity (P<.001). For groups 1Y, 3Y and 8Y, matrix thickness losses were 07, 47 and 70 pm, respectively. Conclusions. Within the limitations of this study, it was observed that one year of clinical wear had limited effect on the ball attachment matrices. Three to 8 years of clinical use resulted in a significant decrease of matrix thickness, especially at the tip of the retentive lamellae. (J Prosthet Dent 2012;107:191-198)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to evaluate, in Nellore heifers, intake and digestibility of hydrolyzed sugarcane stored for different periods. The experimental design used was a 4 × 4 Latin square, four diets, four Nellore heifers with ruminal cannulas (initial body weight 285.4±23.08 kg and average initial age 14 months) and four periods of 21 days. The diets were composed by fresh sugarcane (time zero) or hydrolyzed sugarcane with addition of 0.5% of hydrated lime, stored for 24, 48 or 72 hours, as the unique forage. Intake and digestibility of feed fractions, nitrogen balance, microbial synthesis efficiency, total number of ruminal protozoans and ammoniacal nitrogen did not significantly change by storing sugarcane with addition of 0.5% of hydrated lime. Sugarcane pH varied quadratically for storage time, with maximum pH of 7.02 after 24 hours from lime addition. Ruminal liquid pH values were higher for heifers fed fresh sugarcane, in comparison with those fed hydrolyzed sugarcane. Sugarcane treated with 0.5% of hydrated lime stored for up to 72 hours does not change ruminal digestion to alter the amount of feed consumed by pubescent Nellore heifers. Thus, lime is a viable technology, once it allows long-duration storage and bee control on treated forage, which contributes to animal feeding logistics.