7 resultados para paper-based DGT
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
A polyacrylamide hydrogel containing the Chelex-100 resin has traditionally been used as the binding agent for the diffusion gradients in thin films (DGT) technique. The Chelex-100 resin, although important for the determination of various transition metals, is unsatisfactory for the determination of alkaline earth metals, particularly Ba. In this paper, a cellulose membrane, treated with phosphate (P81 membrane), was evaluated as a binding agent for DGT devices for the determination of Ba in produced formation water (PEW) samples. In addition, diffusive layers of filter paper (cellulose) were tested to diffuse Ba through the DGT devices. Experiments to evaluate the key variables of the technique (pH, deployment time, and ionic strength/salinity) were performed. The Ba sampled by these DGT devices was measured using inductively coupled plasma optical emission spectrometry. Aiming to generate information (related to bioavailability of Ba) on the reuse of PEW for irrigation, the determination of Ba in onshore and offshore samples was performed. The new approach was effective for determination of Ba in onshore samples. To determine Ba in offshore samples, it was necessary to use an alternative calibration procedure due to the high NaCl concentration in these samples. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
The diffusive gradients in thin films (DGT) technique has shown enormous potential for labile metal monitoring in fresh water due to the preconcentration, time-integrated, matrix interference removal and speciation analytical features. In this work, the coupling of energy dispersive X-ray fluorescence (EDXRF) with paper-based DGT devices was evaluated for the direct determination of Mn, Co. Ni, Cu, Zn and Pb in fresh water. The DGT samplers were assembled with cellulose (Whatman 3 MM chromatography paper) as the diffusion layer and a cellulose phosphate ion exchange membrane (Whatman P 81 paper) as the binding agent. The diffusion coefficients of the analytes on 3 MM chromatography paper were calculated by deploying the DGT samplers in synthetic solutions containing 500 mu g L-1 of Mn. Co, Ni, Cu, Zn and Pb (4 L at pH 5.5 and ionic strength at 0.05 mol L-1). After retrieval, the DGT units were disassembled and the P81 papers were dried and analysed by EDXRF directly. The 3 MM chromatographic paper diffusion coefficients of the analytes ranged from 1.67 to 1.87 x 10(-6) cm(2) s(-1). The metal retention and phosphate group homogeneities on the P81 membrane was studied by a spot analysis with a diameter of 1 mm. The proposed approach (DGT-EDXRF coupling) was applied to determine the analytes at five sampling sites (48 h in situ deployment) on the Piracicaba river basin, and the results (labile fraction) were compared with 0.45 mu m dissolved fractions determined by synchrotron radiation-excited total reflection X-ray fluorescence (SR-TXRF). The limits of detection of DGT-EDXRF coupling for the analytes (from 7.5 to 26 mu g L-1) were similar to those obtained by the sensitive SR-TXRF technique (3.8 to 9.1 mu g L-1). (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
This article describes a new design for a paper-based electrochemical system for flow injection analysis. Capillary wicking facilitates a gravity-driven flow of buffer solution continuously through paper and nitrocellulose, from a buffer reservoir at one end of the device to a sink at the other. A difference in height between the reservoir and the sink leads to a continuous and constant flow. The nitrocellulose lies horizontally on a working electrode, which consists of a thin platinum layer deposited on a solid support. The counter and reference electrodes are strategically positioned upstream in the buffer reservoir. A simple pipetting device was developed for reliable application of (sub)microliter volumes of sample without the need of commercial micropipets; this device did not damage the nitrocellulose membrane. Demonstration of the system for the determination of the concentration of glucose in urine resulted in a noninvasive, quantitative assay that could be used for diagnosis and monitoring of diabetes. This method does not require disposable test strips, with enzyme and electrodes, that are thrown away after each measurement Because of its low cost, this system could be used in medical environments that are resource-limited.
Resumo:
This work presents the results from the development of bio-cathodes for the application on paper-based biofuel cells. Our main goal here is to demonstrate the possibility of using different designs of air-breathing bio-cathodes and ink-based bio-cathodes for this new type of paper based electrochemical cell. The electrochemical performance for the bio-electrocatalytic oxygen reduction reaction was studied by using open circuit voltage and amperometry measurements, as well as polarization curves to probe the four-electron reduction reaction of ambient oxygen catalyzed by bilirubin oxidase (BOx). The electrochemical measurements showed that all procedures allowed the direct electron transfer from the active site of the bilirubin oxidase to the electrode surface with a limiting current density of almost 500 mu A cm(-2) for an air-breathing BOx cathode and 150 mu A cm(-2) for an ink based BOx cathode. Under a load of 300 mV a stable current density was obtained for 12 h of continuous operation. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
The Primary Care Information System (SIAB) concentrates basic healthcare information from all different regions of Brazil. The information is collected by primary care teams on a paper-based procedure that degrades the quality of information provided to the healthcare authorities and slows down the process of decision making. To overcome these problems we propose a new data gathering application that uses a mobile device connected to a 3G network and a GPS to be used by the primary care teams for collecting the families' data. A prototype was developed in which a digital version of one SIAB form is made available at the mobile device. The prototype was tested in a basic healthcare unit located in a suburb of Sao Paulo. The results obtained so far have shown that the proposed process is a better alternative for data collecting at primary care, both in terms of data quality and lower deployment time to health care authorities.
Resumo:
Context. Spectrally resolved long-baseline optical/IR interferometry of rotating stars opens perspectives to investigate their fundamental parameters and the physical mechanisms that govern their interior, photosphere, and circumstellar envelope structures. Aims. Based on the signatures of stellar rotation on observed interferometric wavelength-differential phases, we aim to measure angular diameters, rotation velocities, and orientation of stellar rotation axes. Methods. We used the AMBER focal instrument at ESO-VLTI in its high-spectral resolution mode to record interferometric data on the fast rotator Achernar. Differential phases centered on the hydrogen Br gamma line (K band) were obtained during four almost consecutive nights with a continuous Earth-rotation synthesis during similar to 5h/night, corresponding to similar to 60 degrees position angle coverage per baseline. These observations were interpreted with our numerical code dedicated to long-baseline interferometry of rotating stars. Results. By fitting our model to Achernar's differential phases from AMBER, we could measure its equatorial radius R-eq = 11.6 +/- 0.3 R-circle dot, equatorial rotation velocity V-eq = 298 +/- 9 km s(-1), rotation axis inclination angle i = 101.5 +/- 5.2 degrees, and rotation axis position angle (from North to East) PA(rot) = 34.9 +/- 1.6 degrees. From these parameters and the stellar distance, the equatorial angular diameter circle divide(eq) of Achernar is found to be 2.45 +/- 0.09 mas, which is compatible with previous values derived from the commonly used visibility amplitude. In particular, circle divide(eq) and PA(rot) measured in this work with VLTI/AMBER are compatible with the values previously obtained with VLTI/VINCI. Conclusions. The present paper, based on real data, demonstrates the super-resolution potential of differential interferometry for measuring sizes, rotation velocities, and orientation of rotating stars in cases where visibility amplitudes are unavailable and/or when the star is partially or poorly resolved. In particular, we showed that differential phases allow the measurement of sizes up to similar to 4 times smaller than the diffraction-limited angular resolution of the interferometer.
Resumo:
A sensitive and fast-responding membrane-free amperometric gas sensor is described, consisting of a small filter paper foil soaked with a room temperature ionic liquid (RTIL), upon which three electrodes are screen printed with carbon ink, using a suitable mask. It takes advantage of the high electrical conductivity and negligible vapour pressure of RTILs as well as their easy immobilization into a porous and inexpensive supporting material such as paper. Moreover, thanks to a careful control of the preparation procedure, a very close contact between the RTIL and electrode material can be achieved so as to allow gaseous analytes to undergo charge transfer just as soon as they reach the three-phase sites where the electrode material, paper supported RTIL and gas phase meet. Thus, the adverse effect on recorded currents of slow steps such as analyte diffusion and dissolution in a solvent is avoided. To evaluate the performance of this device, it was used as a wall-jet amperometric detector for flow injection analysis of 1-butanethiol vapours, adopted as the model gaseous analyte, present in headspace samples in equilibrium with aqueous solutions at controlled concentrations. With this purpose, the RTIL soaked paper electrochemical detector (RTIL-PED) was assembled by using 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl) imide as the wicking RTIL and printing the working electrode with carbon ink doped with cobalt(II) phthalocyanine, to profit from its ability to electrocatalyze thiol oxidation. The results obtained were quite satisfactory (detection limit: 0.5 mu M; dynamic range: 2-200 mu M, both referring to solution concentrations; correlation coefficient: 0.998; repeatability: +/- 7% RSD; long-term stability: 9%), thus suggesting the possible use of this device for manifold applications.