3 resultados para overlapped peak

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background In the last 20 years, there has been an increase in the incidence of allergic respiratory diseases worldwide and exposure to air pollution has been discussed as one of the factors associated with this increase. The objective of this study was to investigate the effects of air pollution on peak expiratory flow (PEF) and FEV1 in children with and without allergic sensitization. Methods Ninety-six children were followed from April to July, 2004 with spirometry measurements. They were tested for allergic sensitization (IgE, skin prick test, eosinophilia) and asked about allergic symptoms. Air pollution, temperature, and relative humidity data were available. Results Decrements in PEF were observed with previous 24-hr average exposure to air pollution, as well as with 310-day average exposure and were associated mainly with PM10, NO2, and O3 in all three categories of allergic sensitization. Even though allergic sensitized children tended to present larger decrements in the PEF measurements they were not statistically different from the non-allergic sensitized. Decrements in FEV1 were observed mainly with previous 24-hr average exposure and 3-day moving average. Conclusions Decrements in PEF associated with air pollution were observed in children independent from their allergic sensitization status. Their daily exposure to air pollution can be responsible for a chronic inflammatory process that might impair their lung growth and later their lung function in adulthood. Am. J. Ind. Med. 55:10871098, 2012. (c) 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to better understand the events involved in the febrile response induced by cecal ligation and puncture (CLP), a complex infectious process. To this end, we conducted in vivo experiments in rats examining (1) fever development, (2) bacterial number in the infection focus and in blood, (3) peripheral and hypothalamic synthesis of cytokines, (4) hypothalamic and cerebrospinal fluid (CSF) synthesis of prostaglandin E-2 (PGE(2)), (5) the effect of anti-IL-6 antibody on fever, and (6) the effect of celecoxib on fever and hypothalamic synthesis of PGE(2) after CLP induction. We found that CLP promotes fever and animal death depending on the number of punctures. The peak of CLP-induced fever overlapped with the maximal increase in the number of bacteria in the infectious focus and blood, which occurred at 6 and 12 h. The peak of the febrile response also coincided with increased amounts of interleukin (IL)-1 beta, IL-6 and IL-10 in the peritoneal exudate and serum; IL-6 in the hypothalamus and PGE(2) in the CSF and predominantly in the hypothalamus. Moreover, intracerebroventricularly injected anti-IL-6 antibody reduced the febrile response while celecoxib reduced the fever and PGE(2) amount in the hypothalamus induced by CLP. Tumor necrosis factor (TNF)-alpha peaked at 3 h at all sites studied. Conversely, IL-10 concentration decreased in the hypothalamus. These findings show that the peak of CLP-induced fever is accompanied by an increase of bacteria in peritoneal fluid (local infection) and blood; local synthesis of pyrogenic (IL-1 beta, IL-6) and antipyretic (IL-10) cytokines and central production of IL-6 and PGE(2), suggesting that these last are the central mediators of this response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Introduction In this study we aimed to evaluate the peak cough flow (PCF) in healthy Brazilian subjects. Methods We evaluated 484 healthy subjects between 18 and 40 years old. Subjects were seated and oriented were asked to perform a maximal inspiration followed by a quick, short and explosive expiration on the peak flow meter. Three measures were carried out and recorded the average of the three results for each individual. Results The PCF values ranged between 240 and 500 L/min. The PCF values were lower in females than in males. The PCF was inversely proportional to age. Conclusion The values for Brazilian adult healthy subjects regarding PCF were between 240 and 500 L/min.