23 resultados para orthopaedic implants

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) for measuring the buccal bone volume around dental implants. Materials and methods: Three to six implants were inserted into the anterior maxilla of eight skulls, depending on the availability of bone, and after this, the CBCT was performed. By means of CBCT image, measurements of the bone wall at three points of the implant were obtained, analyzed and compared with those obtained in the plaster skull casting. Results: The results showed that for the three points of the implants, no statistically significant difference in the measurements was obtained from the plaster model and CBCT images. Conclusions: CBCT can be a useful tool for assessing buccal bone volume along the implant. To cite this article:?Shiratori LN, Marotti J, Yamanouchi J, Chilvarquer I, Contin I, Tortamano-Neto P. Measurement of buccal bone volume of dental implants by means of cone-beam computed tomography.?Clin. Oral Impl. Res. 23, 2012; 797804.?doi: 10.1111/j.1600-0501.2011.02207.x

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the effect of implant length (6 mm vs. 11 mm) on osseointegration (bone-toimplant contact) of implants installed into sockets immediately after tooth extraction. Material and methods: In six Labrador dogs, the pulp tissue of the mesial roots of P-3(3) was removed and the root canals were filled. Flaps were elevated bilaterally, the premolars hemisectioned and the distal roots removed. Recipient sites were prepared in the distal alveolus and a 6 mm or an 11 mm long implant was installed at the test and control sites, respectively. Non-submerged healing was allowed. After 4 months of healing, block sections of the implant sites were obtained for histological processing and peri-implant tissue assessment. Results: No statistically significant differences were found between test and control sites both for hard and soft tissue parameters. The bone-to-implant contact evaluated at the apical region of the implants was similar as well. Although not statistically significant, the location of the top of the bony crest at the buccal aspect was more apical in relation to the implant shoulder at the test compared with the control sites (2.0 +/- 1.4 and 1.2 +/- 1.1 mm, respectively). Conclusions: Shorter implants (6 mm) present with equal osseointegration than do longer implants (11 mm).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the influence of the presence of both adjacent teeth on the level of alveolar bony crest at sites where implants were installed into the socket immediately after tooth extraction. Material and methods: Six Labrador dogs were used. Extractions of all teeth from the second premolar to the first molar were performed in the right side of the mandible, after full-thickness flap elevation. In the left side of the mandible, an endodontic treatment of the mesial root of the third and fourth premolars was performed. Full-thickness flaps were elevated, the teeth hemisected, and the distal roots removed. Immediately after, implants were bilaterally installed with the margin flush to the buccal bony crest. The implants were placed in the center of the alveolus at the third premolars and toward the lingual bony plate of the alveolus at the fourth premolars. After 3 months of healing, the animals were euthanized. Results: All implants were integrated in mature bone. More bone resorption was observed at the test compared to the control sites. At the buccal aspect, a resorption of 2.8 +/- 0.5 and 1.6 +/- 0.4 mm at the third premolars and of 2.4 +/- 0.6 and 0.8 +/- 0.7 mm at the fourth premolars were found, at the test and control sites, respectively. At the lingual aspect, the bony crest was apically located in relation to the implant shoulder 1.5 +/- 0.3 and 0.5 +/- 0.5 mm at the third premolars and 1.6 +/- 0.6 and 0.3 +/- 1.1 mm at the fourth premolars, at the test and control sites, respectively. A lower buccal bone resorption was found at the control implants placed lingually. Conclusion: Multiple extractions of teeth adjacent to a socket into which implants were installed immediately after, tooth extraction induced more alveolar bone recession compared to sites where the adjacent teeth were preserved. Moreover, an implant placed more lingually yielded less recession of the buccal aspect of the implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Few reports have evaluated cumulative survival rates of extraoral rehabilitation and peri-implant soft tissue reaction at long-term follow-up. The objective of this study was to evaluate implant and prosthesis survival rates and the soft tissue reactions around the extraoral implants used to support craniofacial prostheses. Materials and Methods: A retrospective study was performed of patients who received implants for craniofacial rehabilitation from 2003 to 2010. Two outcome variables were considered: implant and prosthetic success. The following predictor variables were recorded: gender, age, implant placement location, number and size of implants, irradiation status in the treated field, date of prosthesis delivery, soft tissue response, and date of last follow-up. A statistical model was used to estimate survival rates and associated confidence intervals. We randomly selected 1 implant per patient for analysis. Data were analyzed using the Kaplan-Meier method and log-rank test to compare survival curves. Results: A total of 150 titanium implants were placed in 56 patients. The 2-year overall implant survival rates were 94.1% for auricular implants, 90.9% for nasal implants, 100% for orbital implants, and 100% for complex midfacial implants (P = .585). The implant survival rates were 100% for implants placed in irradiated patients and 94.4% for those placed in nonirradiated patients (P = .324). The 2-year overall prosthesis survival rates were 100% for auricular implants, 90.0% for nasal implants, 92.3% for orbital implants, and 100% for complex midfacial implants (P = .363). The evaluation of the peri-implant soft tissue response showed that 15 patients (26.7%) had a grade 0 soft tissue reaction, 30 (53.5%) had grade 1, 6 (10.7%) had grade 2, and 5 (8.9%) had grade 3. Conclusions: From this study, it was concluded that craniofacial rehabilitation with extraoral implants is a safe, reliable, and predictable method to restore the patient's normal appearance. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70:1551-1557, 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, compromising the whole system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate 16 patients of both sexes with lower overdenture and upper complete dentures, by analysing the resonance frequency of the initial and late stability of implants used to retain the overdenture under immediate loading. Background: Oral rehabilitation treatment with complete dentures using implants has been increasingly more common among the specialists in the oral rehabilitation area. This is an alternative for obtaining retention and stability in treatments involving conventional complete dentures, where two implants are enough to retain the overdenture satisfactorily. Materials and methods: The Osstell (TM) Mentor device was used for the analysis in the initial period (primary stability), 3 and 15 months after the installation of the lower overdenture (secondary stability). The statistical analysis was performed with the repeated measures model (p < 0.01). Results: The implant stability quotients were observed to increase after 15 months of the rehabilitating treatment. Conclusion: The use of overdentures over two lower implants should become the treatment of choice for individuals who have a fully edentulous mandible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To describe the healing of marginal defects below or above 1 mm of dimension around submerged implants in a dog model. Material and methods: In 12 Labrador dogs, all mandibular premolars and first molars were extracted bilaterally. After 3 months of healing, full-thickness flaps were elevated in the edentulous region of the right side of the mandible. Two recipient sites were prepared and the marginal 5mm were widened to such an extent to obtain, after implant installation, a marginal gap of 0.5mm at the mesial site (small defect) and of 1.25mm at the distal site (large defect). Titanium healing caps were affixed to the implants and the flaps were sutured allowing a fully submerged healing. The experimental procedures were subsequently performed in the left side of the mandible. The timing of the experiments and sacrifices were planned in such a way to obtain biopsies representing the healing after 5, 10, 20 and 30 days. Ground sections were prepared and histomorphometrically analyzed. Results: The filling of the defect with newly formed bone was incomplete after 1 month of healing in all specimens. Bone formation occurred from the base and the lateral walls of the defects. A larger volume of new bone was formed in the large compared with the small defects. Most of the new bone at the large defect was formed between the 10- and the 20-day period of healing. After 1 month of healing, the outline of the newly formed bone was, however, located at a similar distance from the implant surface (about 0.4mm) at both defect types. Only minor newly formed bone in contact with the implant, starting from the base of the defects, was seen at the large defects (about 0.8mm) while a larger amount was detected at the small defects (about 2.2 mm). Conclusion: Marginal defects around titanium implants appeared to regenerate in 20-30 days by means of a distance osteogenesis. The bone fill of the defects was, however, incomplete after 1 month.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Accelerating bone healing around dental implants can reduce the long-term period between the insertion of implants and functional rehabilitation. Objective: This in vivo study evaluated the effect of a constant electromagnetic field (CEF) on bone healing around dental implants in dogs. Materials and methods: Eight dental implants were placed immediately after extraction of the first premolar and molar teeth on the mandible of two male dogs and divided into experimental (CEF) and control groups. A CEF at magnetic intensity of 0.8 mT with a pulse width of 25 mu s and frequency of 1.5 MHz was applied on the implants for 20 min per day for 2 weeks. Result and conclusion: After qualitative histological analysis, a small quantity of newly formed bone was observed in the gap between the implant surface and alveolar bone in both groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conclusion: The extended retrolabyrinthine approach (RLA) is a safe and reliable approach for auditory brainstem placement in children. The surgical landmarks to reach cochlear nucleus are adequately exposed by this approach. Objective: To describe a new approach option for auditory brainstem implants (ABIs) in children, highlighting the anatomical landmarks to appropriately expose the foramen of Luschka. Methods: Three prelingually deafened children consecutively operated for ABIs via the RLA. Results: ABI placement via the RLA was successfully performed in all children without any further complications except multidirectional nystagmus in one child. The RLA we employed differed from that used for vestibular schwannoma only in the removal of the posterior semicircular canal. The lateral and superior semicircular canals and the vestibule remained intact, and there was no need to expose the dura of the internal auditory meatus. The jugular bulb was completely exposed to allow adequate visualization of the ninth cranial nerve and cerebellar flocculus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of sex, implant characteristics, and bone grafting on the survival rate of dual acid-etched (DAE) implants. Materials and Methods: Patients treated with internal-hex DAE implants for single-tooth replacement in a military dental clinic between January 2005 and December 2010 were included in this study. Clinical data related to implant characteristics, implant location, presence of grafted bone, and implant failures were collected. The primary outcome was implant loss. The survival rate was analyzed using the Kaplan-Meier method. Cox regression modeling was used to determine which factors would predict implant failure. Results: DAE implants were evaluated in a total of 988 patients (80.3% men). Twenty-four (2.4%) implants failed, most were cylindric (54.2%) with regular platforms (70.8%) and were 10 mm long (58.3%). The failure rate was 2.4% for the anterior maxilla, 3.3% for the posterior maxilla, 1.6% for the anterior mandible, and 2.0% for posterior mandible. The cumulative survival rate was 97.6%. The failure rate was 8.8% in implants placed after sinus augmentation, 7.3% in bone block-grafted areas, and 1.6% in native bone. Based on multivariable analysis (Cox regression), sinus augmentation and bone block grafting had a statistically significant effect on implant failure; the hazard ratios were 5.5 and 4.6, respectively. Conclusion: The results revealed that DAE implants had high survival rates, and no influence of sex, location, shape, diameter, or length on failure rates could be observed. However, a significant association was observed between failure and presence of bone graft in the implant area. Int J Oral Maxillofac Implants 2012;27:1243-1248

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface treatment interferes with the primary stability of dental implants because it promotes a chemical and micromorphological change on the surface and thus stimulates osseointegration. This study aimed to evaluate the effects of different surface treatments on primary stability by analyzing insertion torque (IT) and pullout force (PF). Eight samples of implants with different surface treatments (TS - external hexagon with acid surface treatment; and MS - external hexagon, machined surface), all 3.75 mm in diameter x 11.5 mm in length, were inserted into segments of artificial bones. The IT of each sample was measured by an electronic torquemeter, and then the pullout test was done with a universal testing machine. The results were subjected to ANOVA (p < 0.05), followed by Tukey's test (p < 0.05). The IT results showed no statistically significant difference, since the sizes of the implants used were very similar, and the bone used was not highly resistant. The PF values (N) were, respectively, TS = 403.75 +/- 189.80 and MS = 276.38 +/- 110.05. The implants were shown to be different in terms of the variables of maximum force (F = 4.401, p = 0.0120), elasticity in maximum flexion (F = 3.672, p = 0.024), and relative stiffness (F = 4.60, p = 0.01). In this study, external hexagonal implants with acid surface treatment showed the highest values of pullout strength and better stability, which provide greater indication for their use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To standardize the design of individually fitted implants based on computed tomographic (CT) images for use in medialization laryngoplasty without intraoperative voice monitoring. Study Design. Prospective tomographic and anatomical experimental study of 10 human cadaveric larynges. Methods. CT scans of 10 excised human larynges were analyzed to define the shape and size of ideal implants for medialization laryngoplasty. Silicone implants were designed according to CT parameters and used in simulated laryngoplasties in the laryngeal specimens. The efficacy of each implant in providing adequate medialization of the vocal fold was evaluated. Results. Diverse shapes and sizes of implants were obtained, reflecting variations in laryngeal anatomy. The implants enabled regular medialization of the entire extent of the free border of the vocal fold, including its posterior aspect. Medialization was considered adequate in all cases. Conclusions. This method proved to be a simple and efficient way to design individualized implants for medialization laryngoplasty, regardless of the size and shape of the larynx.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present article discusses an atrophic maxilla reconstruction with iliac crest bone block and particulate grafts and dental implants. Onlay block grafts were used to restore bone volume of the anterior maxilla, whereas bilateral sinus floor augmentation was performed using a particulate graft. Ten months after the grafting surgery, 9 dental implants were placed to rehabilitate the case. Results of a 7-year follow-up were obtained clinically and by cone beam computed tomographic images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated bone responses to titanium implants in the presence of an inorganic graft material. The bilateral mandible incisors of 24 rabbits were surgically extracted and one of the exposed sockets, chosen at random, was filled with an inorganic xenogenic bone graft (Gen-ox (R)), whereas the remaining socket was left to heal naturally and served as a control. After 60 days, titanium implants were inserted in the specific areas, and on days 0, 30, 60, and 180 after the implant insertions, six animals of each group were killed. Digital periapical radiography of implant region was obtained and vertical bone height (VBH) and bone density (BD) were evaluated by digital analysis system. In the undecalcified tissue cuts, bone-to-implant contact (BIC) and bone area (BA) within the limits of the implant threads were evaluated and compared statistically by means of two-way ANOVA and Tukey's test (rho < 0.05). No significant differences were detected in VBH and BA, either between groups or between different experimental intervals. The BD was significantly higher in the experimental group than in the control group in all the intervals tested, but there were no significant differences by interval. The BIC was statistically lower in the control group on day 0; however, a significant increase was observed on days 60 and 180 (rho < 0.05). The use of an inorganic xenograft prior to insertion of a titanium implant did not interfere with the course of osseointegration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cochlear implants are the best treatment for congenital profound deafness. Pediatric candidates to implantation are seen as vulnerable citizens, and the decision of implanting cochlear devices is ultimately in the hands of their parents/guardians. The Brazilian Penal Code dictates that deaf people may enjoy diminished criminal capacity. Many are the bioethical controversies around cochlear implants, as representatives from the deaf community have seen in them a means of decimating their culture and intrinsic values. Objective: This paper aims to discuss, in bioethical terms, the validity of implanting cochlear hearing aids in children by analyzing their vulnerability and the social/cultural implications of the procedure itself, aside from looking into the medical/legal aspects connected to their criminal capacity. Materials and Methods: The topic was searched on databases Medline and Lilacs; ethical analysis was done based on principialist bioethics. Results: Cochlear implants are the best therapeutic option for people with profound deafness and are morally justified. The level of criminal capacity attributed to deaf people requires careful analysis of the subject's degree of understanding and determination when carrying out the acts for which he/she has been charged. Conclusion: Cochlear implants are morally valid. Implantations must be analyzed on an each case basis. ENT physicians bear the ethical responsibility for indicating cochlear implants and must properly inform the child's parents/guardians and get their written consent before performing the procedure.