9 resultados para oblique placement

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The irregular shape packing problem is approached. The container has a fixed width and an open dimension to be minimized. The proposed algorithm constructively creates the solution using an ordered list of items and a placement heuristic. Simulated annealing is the adopted metaheuristic to solve the optimization problem. A two-level algorithm is used to minimize the open dimension of the container. To ensure feasible layouts, the concept of collision free region is used. A collision free region represents all possible translations for an item to be placed and may be degenerated. For a moving item, the proposed placement heuristic detects the presence of exact fits (when the item is fully constrained by its surroundings) and exact slides (when the item position is constrained in all but one direction). The relevance of these positions is analyzed and a new placement heuristic is proposed. Computational comparisons on benchmark problems show that the proposed algorithm generated highly competitive solutions. Moreover, our algorithm updated some best known results. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes an evolutionary computing strategy to solve the problem of fault indicator (FI) placement in primary distribution feeders. More specifically, a genetic algorithm (GA) is employed to search for an efficient configuration of FIs, located at the best positions on the main feeder of a real-life distribution system. Thus, the problem is modeled as one of optimization, aimed at improving the distribution reliability indices, while, at the same time, finding the least expensive solution. Based on actual data, the results confirm the efficiency of the GA approach to the FI placement problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports the case of a patient with a severely resorbed mandible who was treated without a bone graft, using short implants, internal rigid fixation, rhBMP-2 and beta-tricalcium phosphate. A 76-year-old woman, with a severely resorbed mandible (less than 3 mm), reported a history of nearly 25 years of complete edentulism and consecutive treatment failures, with total bilateral exposed inferior alveolar nerves and complete bone resorption of the inferior border in some areas. The treatment of choice was the placement of a 2.0 mm thick unilock bone plate (MatrixMandible, Synthes Maxillofacial, Paoli, PA, USA), to reinforce the mandible. Eight short implants with a regular platform (Nobel Biocare, Goteborg, Sweden) were placed: three on the external oblique line on both sides and two on the symphysis. In order to augment mandible height and coat the exposed thread of the anterior implants, rhBMP-2 (Infuse Bone, Meditronic Sofamor Danek, Memphis, TN, USA) and beta-tricalcium phosphate (Cerasorb; Curasan, Kleinostheim, Germany) were used. Four 1.3 mm L miniplates were placed to support the graft. 14 months after surgery, the patient was satisfied and had excellent function without complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The study aimed to assess electrocardiographic alterations during oral implant placement surgeries under local anesthesia (lidocaine chlorhydrate with epinephrine), using 15 mg of midazolam as an anxiolytic premedication. Material and methods: The study randomly selected 20 patients, aged 21-50 years old, requiring bilateral mandibular dental implants. Each patient was assessed using placebo on one side and midazolam on the contralateral side, with random, double-blinded distribution. The electrocardiogram recorded 12 static leads every 2 min, while D2 derivations were recorded continuously. Results: No statistically significant differences were observed between the placebo and midazolam when analyzing the morphological behavior of the electrocardiographic wave and the presence of arrhythmias during the experiment. However, under sedation, assessment of the behavior of electrocardiographic parameters during different stages of the procedure revealed statistically significant differences (P<0.05) for heart rate, P-wave amplitude and duration of the RR and QTc intervals. The arrhythmias detected were considered low risk for patients without systemic alterations and were observed in 53.3% of patients. The most frequently occurring alterations were tachycardia, bradycardia, supraventricular and ventricular extrasystoles and blocked atrial extrasystole, which were similar for both placebo and midazolam, with the greatest incidence during the initial, incision and bone drilling stages. Conclusion: The use of 15 mg of midazolam made no difference compared with the placebo. The use of 15 mg of midazolam did not show an advantage in the incidence of arrhythmias The anxiolytic premedication does not prevent myocardial arrhythmias in endosseous implant placement. The clinical significance of the arrhythmias may not represent serious risks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies in animals have shown pronounced resorption of the buccal bone plate after immediate implantation. The use of flapless surgical procedures prior to the installation of immediate implants, as well as the use of synthetic bone graft in the gaps represent viable alternatives to minimize buccal bone resorption and to favor osseointegration. The aim of this study was to evaluate the healing of the buccal bone plate following immediate implantation using the flapless approach, and to compare this process with sites in which a synthetic bone graft was or was not inserted into the gap between the implant and the buccal bone plate. Lower bicuspids from 8 dogs were bilaterally extracted without the use of flaps, and 4 implants were installed in the alveoli in each side of the mandible and were positioned 2.0 mm from the buccal bone plate (gap). Four groups were devised: 2.0-mm subcrestal implants (3.3 x 8 mm) using bone grafts (SCTG), 2.0-mm subcrestal implants without bone grafts (SCCG), equicrestal implants (3.3 x 10 mm) with bone grafts (EGG), and equicrestal implants without bone grafts (ECCG). One week following the surgical procedures, metallic prostheses were installed, and within 12 weeks the dogs were sacrificed. The blocks containing the individual implants were turned sideways, and radiographic imaging was obtained to analyze the remodeling of the buccal bone plate. In the analysis of the resulting distance between the implant shoulder and the bone crest, statistically significant differences were found in the SCTG when compared to the ECTG (P = .02) and ECCG (P = .03). For mean value comparison of the resulting linear distance between the implant surface and the buccal plate, no statistically significant difference was found among all groups (P > .05). The same result was observed in the parameter for presence or absence of tissue formation between the implant surface and buccal plate. Equicrestally placed implants, in this methodology, presented little or no loss of the buccal bone. The subcrestally positioned implants presented loss of buccal bone, even though synthetic bone graft was used. The buccal bone, however, was always coronal to the implant shoulder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Accelerating bone healing around dental implants can reduce the long-term period between the insertion of implants and functional rehabilitation. Objective: This in vivo study evaluated the effect of a constant electromagnetic field (CEF) on bone healing around dental implants in dogs. Materials and methods: Eight dental implants were placed immediately after extraction of the first premolar and molar teeth on the mandible of two male dogs and divided into experimental (CEF) and control groups. A CEF at magnetic intensity of 0.8 mT with a pulse width of 25 mu s and frequency of 1.5 MHz was applied on the implants for 20 min per day for 2 weeks. Result and conclusion: After qualitative histological analysis, a small quantity of newly formed bone was observed in the gap between the implant surface and alveolar bone in both groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: A morphological analysis of the bone structure of 02 in patients with rheumatoid arthritis in order to enhance the security of the stabilization procedures for this vertebra. Methods: We retrospectively analyzed 20 CT scans of the cervical spine performed in patients with rheumatoid arthritis; the following parameters were measured: spinolaminar angle, thickness and length of C2 lamina. Results: The mean values are: 5.92mm and 5.87mm for thickness of right and left laminae retrospectively, 27.75mm for right lamina length and 27.94mm for left lamina length, and 44.7 degrees for spinolaminar angle. Conclusion: The values obtained are consistent with studies in normal subjects published by other groups, with no apparent need for change in the screw placement technique. Level of Evidence IV, Case Series.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conclusion: The extended retrolabyrinthine approach (RLA) is a safe and reliable approach for auditory brainstem placement in children. The surgical landmarks to reach cochlear nucleus are adequately exposed by this approach. Objective: To describe a new approach option for auditory brainstem implants (ABIs) in children, highlighting the anatomical landmarks to appropriately expose the foramen of Luschka. Methods: Three prelingually deafened children consecutively operated for ABIs via the RLA. Results: ABI placement via the RLA was successfully performed in all children without any further complications except multidirectional nystagmus in one child. The RLA we employed differed from that used for vestibular schwannoma only in the removal of the posterior semicircular canal. The lateral and superior semicircular canals and the vestibule remained intact, and there was no need to expose the dura of the internal auditory meatus. The jugular bulb was completely exposed to allow adequate visualization of the ninth cranial nerve and cerebellar flocculus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a previous work El et al. (2006) [1] exact stable oblique soliton solutions were revealed in two-dimensional nonlinear Schrodinger flow. In this work we show that single soliton solution can be expressed within the Hirota bilinear formalism. An attempt to build two-soliton solutions shows that the system is "close" to integrability provided that the angle between the solitons is small and/or we are in the hypersonic limit. (C) 2012 Elsevier B.V. All rights reserved.