8 resultados para multitracer imaging

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A contaminated site from a downstream municipal solid waste disposal site in Brazil was investigated by using a 3D resistivity and induced polarization (IP) imaging technique. This investigation purpose was to detect and delineate contamination plume produced by wastes. The area was selected based on previous geophysical investigations, and chemical analyses carried out in the site, indicating the presence of a contamination plume in the area. Resistivity model has successfully imaged waste presence (rho < 20 Omega m), water table depth, and groundwater flow direction. A conductive anomaly (rho < 20 Omega m) outside wastes placement was interpreted as a contamination plume. Chargeability model was also able to imaging waste presence (m > 31 mV/V), water table depth, and groundwater flow direction. A higher chargeability zone (m > 31 mV/V) outside wastes placement and following conductive anomaly was interpreted as a contamination plume. Normalized chargeability (MN = m/rho) confirmed polarizable zone, which could be an effect of a salinity increase (contamination plume), and the clay presence in the environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To assess several baseline risk factors that may predict patellofemoral and tibiofemoral cartilage loss during a 6-month period. Methods For 177 subjects with chronic knee pain, 3T magnetic resonance imaging (MRI) of both knees was performed at baseline and followup. Knees were semiquantitatively assessed, evaluating cartilage morphology, subchondral bone marrow lesions, meniscal morphology/extrusion, synovitis, and effusion. Age, sex, and body mass index (BMI), bone marrow lesions, meniscal damage/extrusion, synovitis, effusion, and prevalent cartilage damage in the same subregion were evaluated as possible risk factors for cartilage loss. Logistic regression models were applied to predict cartilage loss. Models were adjusted for age, sex, treatment, and BMI. Results Seventy-nine subregions (1.6%) showed incident or worsening cartilage damage at followup. None of the demographic risk factors was predictive of future cartilage loss. Predictors of patellofemoral cartilage loss were effusion, with an adjusted odds ratio (OR) of 3.5 (95% confidence interval [95% CI] 1.39.4), and prevalent cartilage damage in the same subregion with an adjusted OR of 4.3 (95% CI 1.314.1). Risk factors for tibiofemoral cartilage loss were baseline meniscal extrusion (adjusted OR 3.6 [95% CI 1.310.1]), prevalent bone marrow lesions (adjusted OR 4.7 [95% CI 1.119.5]), and prevalent cartilage damage (adjusted OR 15.3 [95% CI 4.947.4]). Conclusion Cartilage loss over 6 months is rare, but may be detected semiquantitatively by 3T MRI and is most commonly observed in knees with Kellgren/Lawrence grade 3. Predictors of patellofemoral cartilage loss were effusion and prevalent cartilage damage in the same subregion. Predictors of tibiofemoral cartilage loss were prevalent cartilage damage, bone marrow lesions, and meniscal extrusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess the fetal lumbosacral spine by three-dimensional (3D) ultrasonography using volume contrast imaging (VCI) omni view method and compare reproducibility and agreement between three different measurement techniques: standard mouse, high definition mouse and pen-tablet. Methods: A comparative and prospective study with 40 pregnant women between 20 and 34+6 weeks was realized. 3D volume datasets of the fetal spine were acquired using a convex transabdominal transducer. Starting scan plane was the coronal section of fetal lumbosacral spine by VCI-C function. Omni view manual trace was selected and a parallel plane of fetal spine was drawn including interest region. Intraclass correlation coefficient (ICC) was used for reproducibility analysis. The relative difference between three used techniques was compared by chi-square test and Fischer test. Results: Pen-tablet showed better reliability (ICC = 0.987). In the relative proportion of differences, this was significantly higher for the pen-tablet (82.14%; p < 0.01). In paired comparison, the relative difference was significantly greater for the pen-tablet (p < 0.01). Conclusion: The pen-tablet showed to be the most reproductive and concordant method in the measurement of body vertebral area of fetal lumbosacral spine by 3D ultrasonography using the VCI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Rest myocardial perfusion imaging (MPI) is effective in managing patients with acute chest pain in developed countries. We aimed to define the role and feasibility of rest MPI in low-to-middle income countries. Methods and Results. Low-to-intermediate risk patients (n = 356) presenting with chest pain to ten centers in eight developing countries were injected with a Tc-99m-based tracer, and standard imaging was performed. The primary outcome was a composite of death, non-fatal myocardial infarction (MI), recurrent angina, and coronary revascularization at 30 days. Sixty-nine patients had a positive MPI (19.4%), and 52 patients (14.6%) had a primary outcome event. An abnormal rest-MPI result was the only variable which independently predicted the primary outcome [adjusted odds ratio (OR) 8.19, 95% confidence interval 4.10-16.40, P = .0001]. The association of MPI result and the primary outcome was stronger (adjusted OR 17.35) when only the patients injected during pain were considered. Rest-MPI had a negative predictive value of 92.7% for the primary outcome, improving to 99.3% for the hard event composite of death or MI. Conclusions. Our study demonstrates that rest-MPI is a reliable test for ruling out MI when applied to patients in developing countries. (J Nucl Cardiol 2012;19:1146-53.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cone beam computed tomography (CBCT) can be considered as a valuable imaging modality for improving diagnosis and treatment planning to achieve true guidance for several craniofacial surgical interventions. A new concept and perspective in medical informatics is the highlight discussion about the new imaging interactive workflow. The aim of this article was to present, in a short literature review, the usefulness of CBCT technology as an important alternative imaging modality, highlighting current practices and near-term future applications in cutting-edge thought-provoking perspectives for craniofacial surgical assessment. This article explains the state of the art of CBCT improvements, medical workstation, and perspectives of the dedicated unique hardware and software, which can be used from the CBCT source. In conclusion, CBCT technology is developing rapidly, and many advances are on the horizon. Further progress in medical workstations, engineering capabilities, and improvement in independent software-some open source-should be attempted with this new imaging method. The perspectives, challenges, and pitfalls in CBCT will be delineated and evaluated along with the technological developments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate, ex vivo, the nanoleakage in dentinal tubules, the linear infiltration of silver nitrate in the dentin wall/root-end filling material interface, and the presence of gaps in this interface in root-end cavities filled with 4 filling materials. Forty-eight disto-buccal root canals of maxillary molars were instrumented and filled. Retrograde cavities were prepared with ultrasonic points (apical 2 mm). The samples were divided into 2 control groups (n = 4) and 4 experimental groups (n = 10): Group I white mineral trioxide aggregate (MTA); Group II Super EBA; Group III Portland cement; and Group IV Sealer 26. After 1 week, the specimens were subjected to silver nitrate and prepared for SEM (backscattered electrons). In the apical-apical segment, an area with significantly higher leakage was observed for Super EBA, followed by Portland cement, MTA, and Sealer 26 (P = 0.0054). In the medium and cervical segments, all materials showed the same leakage behavior (P = 0.1815 and P = 0.1723, respectively). The linear infiltration at the dentin wall/root-end filling material interface was higher with Super EBA than the other groups. No differences in the percentage of gaps along the 3 mm of dentin wall/root-end filling material interface between the 4 materials were evident (P > 0.05). Nanoleakage occurred mainly in the apical segment of the samples, and Super EBA showed the highest values. The area and linear leakage were lower in the middle and coronal segments, regardless of the root-end filling material. No material perfectly sealed the root-end cavities, which allowed for the leakage occurrence. Microsc. Res. Tech. 75:796800, 2012. (C) 2011 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Dynamic near infrared fluorescence imaging of the urinary tract provides a promising way to diagnose ureteropelvic junction obstruction. Initial studies demonstrated the ability to visualize urine flow and peristalsis in great detail. We analyzed the efficacy of near infrared imaging in evaluating ureteropelvic junction obstruction, renal involvement and the anatomical detail provided compared to conventional imaging modalities. Materials and Methods: Ten swine underwent partial or complete unilateral ureteral obstruction. Groups were survived for the short or the long term. Imaging was performed with mercaptoacetyltriglycine diuretic renogram, magnetic resonance urogram, excretory urogram, ultrasound and near infrared imaging. Scoring systems for ureteropelvic junction obstruction were developed for magnetic resonance urogram and near infrared imaging. Physicians and medical students graded ureteropelvic junction obstruction based on magnetic resonance urogram and near infrared imaging results. Results: Markers of vascular and urinary dynamics were quantitatively consistent among control renal units. The same markers were abnormal in obstructed renal units with significantly different times of renal phase peak, start of pelvic phase and start of renal uptake. Such parameters were consistent with those obtained with mercaptoacetyltriglycine diuretic renography. Near infrared imaging provided live imaging of urinary flow, which was helpful in identifying the area of obstruction for surgical planning. Physicians and medical students categorized the degree of obstruction appropriately for fluorescence imaging and magnetic resonance urogram. Conclusions: Near infrared imaging offers a feasible way to obtain live, dynamic images of urine flow and ureteral peristalsis. Qualitative and quantitative parameters were comparable to those of conventional imaging. Findings support fluorescence imaging as an accurate, easy to use method of diagnosing ureteropelvic junction obstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess the correlation between MRI findings of the pancreas with those of the heart and liver in patients with beta thalassemia; to compare the pancreas T2* MRI results with glucose and ferritin levels and labile plasma iron (LPI). Materials and methods: We retrospectively evaluated chronically transfused patients, testing glucose with enzymatic tests, serum ferritin with chemiluminescence, LPI with cellular fluorescence, and T2* MRI to assess iron content in the heart, liver, and pancreas. MRI results were compared with one another and with serum glucose, ferritin, and LPI. Liver iron concentration (LIC) was determined in 11 patients' liver biopsies by atomic absorption spectrometry. Results: 289 MRI studies were available from 115 patients during the period studied. 9.4% of patients had overt diabetes and an additional 16% of patients had impaired fasting glucose. Both pancreatic and cardiac R2* had predictive power (p < 0.0001) for identifying diabetes. Cardiac and pancreatic R2* were modestly correlated with one another (r(2) = 0.20, p < 0.0001). Both were weakly correlated with LIC (r(2) = 0.09, p < 0.0001 for both) and serum ferritin (r(2) = 0.14, p < 0.0001 and r(2) = 0.03, p < 0.02, respectively). None of the three served as a screening tool for single observations. There is a strong log-log, or power-law, relationship between ratio of signal intensity (SIR) values and pancreas R2* with an r(2) of 0.91. Conclusions: Pancreatic iron overload can be assessed by MRI, but siderosis in other organs did not correlate significantly with pancreatic hemosiderosis. (C) 2011 Elsevier Ireland Ltd. All rights reserved.