6 resultados para maxillomandibular advancement
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Purpose: The aims of the study were to measure endoscopically the retrolingual pharynx during wakefulness and sleep before and after maxillomandibular advancement surgery and to quantify the changes observed. Materials and Methods: Eighteen patients with mild to severe grade obstructive sleep apnea hypopnea were evaluated during wakefulness while sitting and lying down and during induced sleep in dorsal decubitus while breathing naturally. Images of the retrolingual region of the pharynx were captured with a nasofibroscope and recorded on a DVD using the Sony Vegas 8.0 software (Sony Creative Software, Madison, WI). The images captured in greater and smaller aperture were measured with the Image J software (produced by Wayne Rasband, United States National Institutes of Health, Bethesda, MD) in linear anteroposterior and linear laterolateral areas. A correction factor was then applied to equalize the size of the images and thus compare them to one another. Results: The postoperative dimensions of the pharynx always increased significantly in all measurements compared with the preoperative ones. During induced sleep in dorsal decubitus, there was a greater gain in the area of smaller aperture (201.33%). Conclusions: The proposed method showed that the dimensions of the pharynx always increased significantly after surgery for maxillomandibular advancement, although the gain was not homogeneous in all dimensions and also varied according to state of consciousness. The greatest gain was observed in the area of smaller aperture with the patient in induced sleep, thus reducing the collapse of the pharynx. (C) 2012 Elsevier Inc. All rights reserved.
Resumo:
Among the osteotomies performed in orthognathic surgery, the sagittal osteotomy of the mandibular ramus (SOMR) is the most common, allowing a great range of movements and stable internal fixation (SIF), therefore eliminating the need of maxillomandibular block in the postoperative period. Objectives: The purpose of this study was to evaluate the biomechanical resistance of three national systems used for SIF in SOMR in sheep mandibles. Material and methods: The study was performed in 30 sheep hemi-mandibles randomly divided into 3 experimental groups, each containing 10 hemi-mandibles. The samples were measured to avoid discrepancies and then subjected to SOMR with 5-mm advancement. In group I, 2.0x12 mm screws were used for fixation, inserted in an inverted "L" pattern (inverted "L" group). In group II, fixation was performed with two 2.0x12 mm screws, positioned in a linear pattern and a 4-hole straight miniplate and four 2.0x6.0 mm monocortical screws (hybrid group). In group III, fixation was performed with two-hole straight miniplates and eight 2.0x6.0 mm monocortical screws (mini plate group). All materials used for SIF were supplied by Osteosin - SIN. The hemimandibles were subjected to vertical linear load test by Kratos K2000MP mechanical testing unit for loading registration and displacement. Results: All groups showed similar resistance during mechanical test for loading and displacement, with no statistically significant differences between groups according to analysis of variance. Conclusion: These results indicate that the three techniques of fixation are equally effective for clinical fixation of SOMR.
Resumo:
Bars and steel wires are the most commonly used methods to achieve maxillomandibular fixation, although there are numerous alternatives described for this same purpose. In cases of edentulous candidates for the conservative treatment of facial fractures, none of the conventional methods can be instituted for maxillomandibular fixation. Fixation in such cases is achieved with the aid of the total dentures of the patient or the confection of splints, but these methods lead to eating and oral hygiene problems. This article reports the case of an edentulous patient with a comminuted mandible fracture treated with a rarely described technique in which intermaxillary fixation was achieved with titanium miniplates.
Resumo:
The main purposes of this manuscript are to provide an overview of various modalities of surgical correction of anterior plagiocephaly and to emphasize their differences with the classic open frontal-orbital advancement. Advancement of technology provides development of many other ways to achieve the same results. The authors describe the classic open frontal-orbital advancement and compare with other proposed techniques for correction of frontal plagiocephaly. The main limitation of the use of new forms of treatment of the anterior plagiocephaly is the age of the patient. There is still no consensus on criteria for quantitative evaluation of surgical results, and new forms of treatment do not present results with long follow-up. Frontal-orbital advancement is the preferred procedure to correct unicoronal synostosis due to its universal indication regardless of the age and degree of deformation of the anterior plagiocephaly.
Resumo:
Objective: To assess the effects produced by the MARA appliance in the treatment of Angle’s Class II, division 1 malocclusion. Methods: The sample consisted of 44 young patients divided into two groups: The MARA Group, with initial mean age of 11.99 years, treated with the MARA appliance for an average period of 1.11 years, and the Control Group, with initial mean age of 11.63 years, monitored for a mean period of 1.18 years with no treatment. Lateral cephalograms were used to compare the groups using cephalometric variables in the initial and final phases. For these comparisons, Student’s t test was employed. Results: MARA appliance produced the following effects: Maxillary growth restriction, no change in mandibular development, improvement in maxillomandibular relationship, increased lower anterior facial height and counterclockwise rotation of the functional occlusal plane. In the upper arch, the incisors moved lingually and retruded, while the molars moved distally and tipped distally. In the lower arch, the incisors proclined and protruded, whereas the molars mesialized and tipped mesially. Finally, there was a significant reduction in overbite and overjet, with an obvious improvement in molar relationship. Conclusions: It was concluded that the MARA appliance proved effective in correcting Angle’s Class II, division 1 malocclusion while inducing skeletal changes and particularly dental changes.
Resumo:
INTRODUCTION: Among the sleep disorders reported by the American Academy of Sleep, the most common is obstructive sleep apnea-hypopnea syndrome (OSAHS), which is caused by difficulties in air passage and complete interruption of air flow in the airway. This syndrome is associated with increased morbidity and mortality in apneic individuals. OBJECTIVE: It was the objective of this paper to evaluate a removable mandibular advancement device as it provides a noninvasive, straightforward treatment readily accepted by patients. METHODS: In this study, 15 patients without temporomandibular disorders (TMD) and with excessive daytime sleepiness or snoring were evaluated. Data were collected by means of: Polysomnography before and after placement of an intraoral appliance, analysis of TMD signs and symptoms using a patient history questionnaire, muscle and TMJ palpation. RESULTS: After treatment, the statistical analysis (t-test, and the "before and after" test) showed a mean reduction of 77.6% (p=0.001) in the apnea-hypopnea index, an increase in lowest oxyhemoglobin saturation (p=0.05), decrease in desaturation (p=0.05), decrease in micro-awakenings or EEG arousals (p=0.05) and highly significant improvement in daytime sleepiness (p=0.005), measured by the Epworth Sleepiness Scale. No TMD appeared during the monitoring period. CONCLUSION: The oral device developed in this study was considered effective for mild to moderate OSAHS.