11 resultados para intraocular prosthesis

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING: Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil. DESIGN: Prospective randomized double-masked comparative clinical trial. METHODS: One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS: Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION: Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal +3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Odontogenic myxomas are considered to be a benign odontogenic tumor with locally aggressive behavior. Because these neoplasms are rare in the oral cavity, the possible surgical management can be quite variable. Literature recommendation can vary from simple curettage and peripheral ostectomy to segmental resection. The authors report a case of a 20-year-old patient with an odontogenic myxoma tumor located in the left mandibular angle, ascending ramus, and mandibular symphysis. It was treated by radical resection followed by titanium reconstruction with condylar prosthesis, which allowed rapid return of function with improvement in quality of life and restoration of cosmetic and functional deficits. The lesion did not recur after surgical procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Few reports have evaluated cumulative survival rates of extraoral rehabilitation and peri-implant soft tissue reaction at long-term follow-up. The objective of this study was to evaluate implant and prosthesis survival rates and the soft tissue reactions around the extraoral implants used to support craniofacial prostheses. Materials and Methods: A retrospective study was performed of patients who received implants for craniofacial rehabilitation from 2003 to 2010. Two outcome variables were considered: implant and prosthetic success. The following predictor variables were recorded: gender, age, implant placement location, number and size of implants, irradiation status in the treated field, date of prosthesis delivery, soft tissue response, and date of last follow-up. A statistical model was used to estimate survival rates and associated confidence intervals. We randomly selected 1 implant per patient for analysis. Data were analyzed using the Kaplan-Meier method and log-rank test to compare survival curves. Results: A total of 150 titanium implants were placed in 56 patients. The 2-year overall implant survival rates were 94.1% for auricular implants, 90.9% for nasal implants, 100% for orbital implants, and 100% for complex midfacial implants (P = .585). The implant survival rates were 100% for implants placed in irradiated patients and 94.4% for those placed in nonirradiated patients (P = .324). The 2-year overall prosthesis survival rates were 100% for auricular implants, 90.0% for nasal implants, 92.3% for orbital implants, and 100% for complex midfacial implants (P = .363). The evaluation of the peri-implant soft tissue response showed that 15 patients (26.7%) had a grade 0 soft tissue reaction, 30 (53.5%) had grade 1, 6 (10.7%) had grade 2, and 5 (8.9%) had grade 3. Conclusions: From this study, it was concluded that craniofacial rehabilitation with extraoral implants is a safe, reliable, and predictable method to restore the patient's normal appearance. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70:1551-1557, 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, compromising the whole system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to warn the dental community about a possible problem in function with partial implant-supported prostheses used for long periods. The misalignment between natural teeth and the implant-supported prosthesis on teeth 11 and 12, observed in a 14-year clinical follow-up, illustrates the fact. The metal-ceramic crowns were placed in 1995 after a rigorous occlusal adjustment. Evaluations were made at 4, 6, 9, and 14 years, when it was noticed that the restorations were positioned palatally and extruded in comparison with the natural teeth. After 9 years, a greater discrepancy was noticed, with anterior occlusion and esthetic changes. The possible causes have been discussed: occlusal problems, parafunctional habits, and natural movement. The first 2 options were discarded after clinical analysis and diagnosis. Therefore, the natural movement probably deriving from an interaction of mechanical and genetic factors might have been the cause. The implants do not have periodontal ligaments but rather ankylosis, so they do not suffer those movements. This case emphasizes the need to inform patients that implants can last more than 10 years in function, but this is not the case with restorations, which lose function and esthetics and must be replaced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To describe a new method for iris fixation of intraocular lens in the absence of capsular support during penetrating keratoplasty. Its a new technique of iris fixation of intraocular lens without capsular support during penetrating keratoplasty. This technique is used in cases with a healthy iris and partial or total absence of capsular support during penetrating keratoplasty. Tied Out Open Sky is a technique easy to perform for iris fixation of intraocular lens during penetrating keratoplasty. The big advantage is being able to tie off the intraocular lens off the eye and fasten it securely.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS. Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed. RESULTS. The results on the tightened side were significantly lower in Group C (6.43 +/- 3.24 mu m) when compared to Groups A (16.50 +/- 7.55 mu m) and B (16.27 +/- 1.71 mu m) (P<.05). On the opposite side, the diagonal section of the one-piece castings for laser welding showed significant improvement in the levels of misfit of the frameworks (Group A, 58.66 +/- 14.30 mu m; Group B, 39.4.8 +/- 12.03 mu m; Group C, 23.13 +/- 8.24 mu m) (P<.05). CONCLUSION. Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks. [J Adv Prosthodont 2012;4:89-92]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the colour stability of paints used for ocular prosthesis iris painting submitted for accelerated artificial ageing (AAA). Materials and methods: Forty specimens of acrylic resin for sclera (16 x 2 mm) were made and separated into eight groups (n = 10) according to the type of paint (gouache, GP; oil, OP; acrylic AP; and composite resin for characterisation, CR) and the colours used (blue/brown). After drying (72 h), a new layer of colourless acrylic resin was applied and the initial colour readout was performed (Spectrophotometer PCB 6807). New colour readouts were performed after AAA, and Delta E was calculated. Results: Statistical analysis (two-way ANOVA-Bonferroni, p < 0.05) demonstrated that the brown colour showed lower Delta E means in comparison with the blue colour, with statistically significant difference for AP only. Blue colour showed no statistically significant difference with regard to the type of paint used. Brown AP showed lower Delta E than the other groups, with significant difference for OP and GP. GP showed greater alteration in Delta E for the brown colour, being statistically similar only to OP. Conclusions: Only the AP group for brown pigment shows clinically acceptable values for colour stability after AAA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate alignment of a toric intraocular lens (IOL) is a requisite to achieving the intended reduction in astigmatism at the time of cataract surgery. However, it requires a reasonably clear view of the limbal vascular anatomy, which is sometimes altered by chemosis from a subconjunctival anesthetic injection or a hemorrhage. We describe a technique that can quickly restore vascular anatomy and facilitate toric IOL alignment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL) on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes) received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes) received ultraviolet and blue light filter (yellow tinted) IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD]) investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens) difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens) under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.