7 resultados para indirect method
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Four castrated crossbred horses were used in a randomized block design to study the use of indigestible internal markers iNDF and iADF obtained in situ (from bovines) or in vivo (from equines). Treatments consisted of determining digestibility by the direct method comprising total feces collection (TC) and by the indirect method comprising internal markers iNDF and iADF obtained by in situ incubation in bovine rumen or in vivo by the mobile nylon bag (MNB) technique with horses. iNDF-IV and iADF-IV resulted in better marker recovery rate (RR) (91.50%), similar to TC. The in situ technique resulted in lower RR values for the two indigestible markers, averaging 86.50% (p < 0.05). Estimates of the nutrient coefficient of digestibility (CD) were adequately predicted by iADF-IV, for horses fed on hay exclusively, with rates 46.41, 48.16, 47.92 and 45.51% for dry matter (DM), organic matter (OM), FDN and gross energy, respectively. Results show that MNB may be used to obtain iADF in horses fed on coast-cross hay exclusively, whereas NDFi and ADFi were selected for horses fed on mixed diets to predict the coefficient of nutrient digestibility.
Resumo:
Four crossbred geldings were used in a randomized blocks experimental design. The objective was to study the use of the internal markers indigestible cellulose (iCEL) and indigestible lignin (iLIG), obtained in situ (cattle) or in vivo (equine) to predict nutrient apparent digestibility in horses. Treatments consisted of different methodologies to determine digestibility: direct method with total feces collection (TC), and indirect method using internal markers iCEL and iLIG obtained either by in situ incubation in bovine rumen or in vivo (IV) using the mobile nylon bag (MNB) technique in horses. Feces production was 2.80 kg in DM, and average recovery rate (p > 0.05) was 101%. Nutrient digestibility coefficient (p > 0.05) estimates were adequately predicted by iCEL and iLIG, obtained in situ or in vivo, with average values of 52.63, 54.17, 64.90, 43.73 and 98.28% for dry matter, organic matter, crude protein, neutral detergent fiber and starch, respectively. It can be concluded that iCEL and iLIG may be obtained in vivo by MNB in horses consuming a forage-concentrate diet, to predict nutrient digestibility coefficients.
Resumo:
PURPOSE: To compare the direct and indirect radiographic methods for assessing the gray levels of biomaterials employing the Digora for Windows and the Adobe Photoshop CS2 systems. METHODS: Specimens of biomaterials were made following manusfacturer's instructions and placed on phosphor storage plates (PSP) and on radiographic film for subsequent gray level assessment using the direct and indirect radiographic method, respectively. The radiographic density of each biomaterial was analyzed using Adobe Photoshop CS2 and Digora for Windows software. RESULTS: The distribution of gray levels found using the direct and indirect methods suggests that higher exposure times are correlated to lower reproducibility rates between groups. CONCLUSION: The indirect method is a feasible alternative to the direct method in assessing the radiographic gray levels of biomaterials, insofar as significant reproducibility was observed between groups for the exposure times of 0.2 to 0.5 seconds.
Resumo:
The aim of this study is to develop a new enzymeless electroanalytical method for the indirect quantification of creatinine from urine sample. This method is based on the electrochemical monitoring of picrate anion reduction at a glassy carbon electrode in an alkaline medium before and after it has reacted with creatinine (Jaffe's reaction). By using the differential pulse voltammetry technique under the optimum experimental conditions (step potential, amplitude potential, reaction time, and temperature), a linear analytical curve was obtained for concentrations of creatinine ranging from 1 to 80 mu mol L-1, with a detection limit of 380 nmol L-1. This proposed method was used to measure creatinine in human urine without the interference of most common organic species normally present in biological fluids (e.g., uric acid, ascorbic acid, glucose, and phosphocreatinine). The results obtained using urine samples were highly similar to the results obtained using the reference spectrophotometric method (at a 95% confidence level). (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Zebrafish are currently used at various stages of the drug discovery process and can be a useful and cost-effective alternative to some mammalian models. Nitric oxide (NO) plays an important role in physiology of zebrafish. The availability of appropriate analytical techniques to quantify the NO is crucial for studying its role in physiological and pathological conditions. This work aimed at establishing a high-performance liquid chromatography method for determination of NO levels in zebrafish larvae. Attempts were also made to assess the normal levels of NO at the first days postfertilization and the possible changes under pathological conditions. The method validation was quantitatively evaluated in terms of sensitivity, specificity, precision, accuracy, linearity, and recovery. NO levels from zebrafish larvae at the first days postfertilization and larvae challenged to N(G)-nitro-L-arginine methyl ester, sodium nitroprusside, Escherichia coil lipopolysaccharide, and copper sulfate were analyzed. The samples were derivatized with 2,3-diaminonaphthalene, and fluorescence detection was used for the indirect determination of NO. The method showed a good performance for all validation parameters evaluated and was efficient to monitor changes in NO concentration under physiological and pathophysiological conditions. This method might represent a powerful tool to be applied in NO studies with zebrafish larvae. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
Nanoplasmonics and metamaterials sciences are rapidly growing due to their contributions to photonic devices fabrication with applications ranging from biomedicine to photovoltaic cells. Noble metal nanoparticles incorporated into polymer matrix have great potential for such applications due to their distinctive optical properties. However, methods to indirectly incorporate metal nanoparticles into polymeric microstructures are still on demand. Here we report on the fabrication of two-photon polymerized microstructures doped with gold nanoparticles through an indirect doping process, so they do not interfere in the two-photon polymerization (2PP) process. Such microstructures present a strong emission, arising from gold nanoparticles fluorescence. The microstructures produced are potential candidates for nanoplasmonics and metamaterials devices applications and the nanoparticles production method can be applied in many samples, heated simultaneously, opening the possibility for large scale processes. (C) 2012 Optical Society of America
Resumo:
A new method for analysis of scattering data from lamellar bilayer systems is presented. The method employs a form-free description of the cross-section structure of the bilayer and the fit is performed directly to the scattering data, introducing also a structure factor when required. The cross-section structure (electron density profile in the case of X-ray scattering) is described by a set of Gaussian functions and the technique is termed Gaussian deconvolution. The coefficients of the Gaussians are optimized using a constrained least-squares routine that induces smoothness of the electron density profile. The optimization is coupled with the point-of-inflection method for determining the optimal weight of the smoothness. With the new approach, it is possible to optimize simultaneously the form factor, structure factor and several other parameters in the model. The applicability of this method is demonstrated by using it in a study of a multilamellar system composed of lecithin bilayers, where the form factor and structure factor are obtained simultaneously, and the obtained results provided new insight into this very well known system.