7 resultados para implementation results

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a method for electromagnetic torque ripple and copper losses reduction in (non-sinusoidal or trapezoidal) surface-mount permanent magnet synchronous machines (SM-PMSM). The method is based on an extension of classical dq transformation that makes it possible to write a vectorial model for this kind of machine (with a non-sinusoidal back-EMF waveform). This model is obtained by the application of that transformation in the classical machine per-phase model. That transformation can be applied to machines that have any type of back-EMF waveform, and not only trapezoidal or square-wave back-EMF waveforms. Implementation results are shown for an electrical converter, using the proposed vectorial model, feeding a non-sinusoidal synchronous machine (brushless DC motor). They show that the use of this vectorial mode is a way to achieve improvements in the performance of this kind of machine, considering the electromagnetic torque ripple and copper losses, if compared to a drive system that employs a classical six-step mode as a converter. Copyright (C) 2011 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study reports the implementation of GMPs in a mozzarella cheese processing plant. The mozzarella cheese manufacturing unit is located in the Southwestern region of the state of Parana, Brazil, and processes 20,000 L of milk daily. The implementation of GMP took place with the creation of a multi-disciplinary team and it was carried out in four steps: diagnosis, report of the diagnosis and road map, corrective measures and follow-up of GMP implementation. The effectiveness of actions taken and GMP implementation was compared by the total percentages of non-conformities and conformities before and after implementation of GMR Microbiological indicators were also used to assess the implementation of GMP in the mozzarella cheese processing facility. Results showed that the average percentage of conformity after the implementation of GMP was significant increased to 66%, while before it was 32% (p < 0.05). The populations of aerobic microorganisms and total coliforms in equipment were significantly reduced (p < 0.05) after the implementation of GMP, as well as the populations of total coliforms in the hands of food handlers (p < 0.05). In conclusion, GMP implementation changed the overall organization of the cheese processing unity, as well as managers and food handlers' behavior and knowledge on the quality and safety of products manufactured. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Brazil, Protected Areas (PAs) are considered the cornerstone for development of national strategies for biodiversity conservation. Considering this point of view we analyzed thirty protected areas belonging to Atlantic Central Corridor of Atlantic Forest in Bahia, aiming to identify and analyze its current level of implementation. Lemos de Sa and Ferreira (2000) methodology which consist of applying a standard scale, where the variation of the level of implementation conforms to a range of 0 to 5 points was used, with appropriate adaptations. After obtaining the data from the implementation level we use the aggregation method of Ward to help visualize the dissimilarity between the protected areas studied. We used an international classification proposed by IUCN (International Union for Conservation of Nature) for that the UCs to be compared with works done in another countries, the UCs considered are in the groups Ia, II, V and VI da IUCN. As results, 50% of protected areas analyzed are reasonably implemented, 40% inadequately implemented, 6.7% are presented only on paper and only 3.3% can be classified as satisfactorily implemented. These areas presents problems in their regularization; deficiency in infrastructure, human and financial resources. Given the results its clear the recurrent fact that conservation areas under study must be effectively implemented and for this to occur environmental policies should be focused on actions to consolidate the goals of conservation strategy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Breast cancer is the most frequently diagnosed cancer and the leading cause of cancer deaths among women worldwide. The use of mobile mammography units to offer screening to women living in remote areas is a rational strategy to increase the number of women examined. This study aimed to evaluate results from the first 2 years of a government-organized mammography screening program implemented with a mobile unit (MU) and a fixed unit (FU) in a rural county in Brazil. The program offered breast cancer screening to women living in Barretos and the surrounding area. Methods: Based on epidemiologic data, 54 238 women, aged 40 to 69 years, were eligible for breast cancer screening. The study included women examined from April 1, 2003 to March 31, 2005. The chi-square test and Bonferroni correction analyses were used to evaluate the frequencies of tumors and the importance of clinical parameters and tumor characteristics. Significance was set at p < 0.05. Results: Overall, 17 964 women underwent mammography. This represented 33.1% of eligible women in the area. A mean of 18.6 and 26.3 women per day were examined in the FU and MU, respectively. Seventy six patients were diagnosed with breast cancer (41 (54%) in the MU). This represented 4.2 cases of breast cancer per 1000 examinations. The number of cancers detected was significantly higher in women aged 60 to 69 years than in those aged 50 to 59 years (p < 0.001) or 40 to 49 years (p < 0.001). No difference was observed between women aged 40 to 49 years and those aged 50 to 59 years (p = 0.164). The proportion of tumors in the early (EC 0 and EC I) and advanced (CS III and CS IV) stages of development were 43.4% and 15.8%, respectively. Conclusions: Preliminary results indicate that this mammography screening program is feasible for implementation in a rural Brazilian territory and favor program continuation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background The public health system of Brazil is structured by a network of increasing complexity, but the low resolution of emergency care at pre-hospital units and the lack of organization of patient flow overloaded the hospitals, mainly the ones of higher complexity. The knowledge of this phenomenon induced Ribeirão Preto to implement the Medical Regulation Office and the Mobile Emergency Attendance System. The objective of this study was to analyze the impact of these services on the gravity profile of non-traumatic afflictions in a University Hospital. Methods The study conducted a retrospective analysis of the medical records of 906 patients older than 13 years of age who entered the Emergency Care Unit of the Hospital of the University of São Paulo School of Medicine at Ribeirão Preto. All presented acute non-traumatic afflictions and were admitted to the Internal Medicine, Surgery or Neurology Departments during two study periods: May 1996 (prior to) and May 2001 (after the implementation of the Medical Regulation Office and Mobile Emergency Attendance System). Demographics and mortality risk levels calculated by Acute Physiology and Chronic Health Evaluation II (APACHE II) were determined. Results From 1996 to 2001, the mean age increased from 49 ± 0.9 to 52 ± 0.9 (P = 0.021), as did the percentage of co-morbidities, from 66.6 to 77.0 (P = 0.0001), the number of in-hospital complications from 260 to 284 (P = 0.0001), the mean calculated APACHE II mortality risk increased from 12.0 ± 0.5 to 14.8 ± 0.6 (P = 0.0008) and mortality rate from 6.1 to 12.2 (P = 0.002). The differences were more significant for patients admitted to the Internal Medicine Department. Conclusion The implementation of the Medical Regulation and Mobile Emergency Attendance System contributed to directing patients with higher gravity scores to the Emergency Care Unit, demonstrating the potential of these services for hierarchical structuring of pre-hospital networks and referrals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening. Aim: To evaluate the TS audiometer for conducting audiometric screening. Methods: A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated. Results: For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively. Conclusions: The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe the planning, implementation, and initial results of the first planned move of the default position of spectra on the Hubble Space Telescope's Cosmic Origins Spectrograph (COS) Far Ultraviolet (FUV) cross-delay line detector. This was motivated by the limited amount of charge that can be extracted from the microchannel plate due to gain sag at any one position. Operations at a new location began on July 23, 2012, with a shift of the spectrum by +3.5"(corresponding to ~ 41 pixels or ~ 1 mm) in a direction orthogonal to the spectral dispersion. Operation at this second "lifetime position" allows for spectra to be collected which are not affected by detector artifacts and loss of sensitivity due to gain sag. We discuss programs designed to enable operations at the new lifetime position; these include determinations of operational high voltage, measuring walk corrections and focus, confirming spectrum placement and aperture centering, and target acquisition performance. We also present results related to calibration of the new lifetime position, including measurements of spectral resolution and wavelength calibration, flux and flat field calibration, carryover of time-dependent sensitivity monitoring, and operations with the Bright Object Aperture (BOA).