8 resultados para implanted antenna

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ion implantation of metal species into insulators provides a tool for the formation of thin, electrically conducting, surface layers with experimenter-controlled resistivity. High energy implantation of Pt and Ti into alumina accelerator components has been successfully employed to control high voltage surface breakdown in a number of cases. In the work described here we have carried out some basic investigations related to the origin of this phenomenon. By comparison of the results of alumina implanted with Ti at 75 keV with the results of prior investigations of polymers implanted with Pt at 49 eV and Au at 67 eV, we describe a physical model of the effect based on percolation theory and estimate the percolation parameters for the Ti-alumina composite. We estimate that the percolation dose threshold is about 4 x 10(16) cm(-2) and the maximum dose for which the system remains an insulator-conductor composite is about 10 x 10(16) cm(-2). The saturation electrical conductivity is estimated to be about 50 S/m. We conclude that the observed electrical conductivity properties of Ti-implanted alumina can be satisfactorily described by percolation theory. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.3697900]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-level laser therapy is a tool employed in the management of post-operative inflammation process and in the enhancement of reparative process. The aim of the study was to perform histological evaluation of dental and periodontal ligament of rats central upper-left incisor teeth re-implanted and irradiated with low-level laser (InGaAl, 685 nm, 50 J/cm(2)) 15, 30, and 60 days after re-implantation. Seventy-two male rats had the central upper left incisor removed and kept for 15 min on dry gauze before replantation. Laser was irradiated over the root surface and empty alveolus prior replantation and over surrounding mucosa after the re-implantation. After histological procedures, all slices were analyzed regarding external resorption area and histological aspects. We observed an increase of root resorption (p < 0.05) in the control group compared to the laser group at 15, 30, and 60 days. These results showed that the laser groups developed less root resorption areas than the control group in all experimental periods. Additionally, histological analysis revealed less inflammatory cells and necrotic areas in laser groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We tested the hypothesis that the osteoblast differentiation status of bone marrow stem cells (BMSCs) combined with a three-dimensional (3D) structure modulates bone formation when autogenously implanted. Rat BMSCs were aspirated, expanded, and seeded into a 3D composite of poly(lactide-co-glycolide) and calcium phosphate (PLGA/CaP) to produce a hybrid biomaterial. Calvarial defects were implanted with (1) scaffold without cells (SC/NC), (2) scaffold and BMSCs (SC + BMSC), (3) scaffold and osteoblasts differentiated for 7 days (SC + OB7), and (4) for 14 days (SC + OB14). After 4 weeks, there was more bone formation in groups combining scaffold and cells, SC + BMSC and SC + OB7. A nonsignificant higher amount of bone formation was observed on SC + OB14 compared with SC/NC. Additionally, more blood vessels were counted within all hybrid biomaterials, without differences among them, than into SC/NC. These findings provide evidences that the cell differentiation status affects in vivo bone formation in autogenously implanted cell-based constructs. Undifferentiated BMSCs or osteoblasts in early stage of differentiation combined with PLGA/CaP scaffold favored bone formation compared with plain scaffold and that one associated with more mature osteoblasts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The purpose of this study was to evaluate the effect of the duodenal-jejunal bypass liner (DJBL), a 60-cm, impermeable fluoropolymer liner anchored in the duodenum to create a duodenal-jejunal bypass, on metabolic parameters in obese subjects with type 2 diabetes. Methods: Twenty-two subjects (mean age, 46.2 +/- 10.5 years) with type 2 diabetes and a body mass index between 40 and 60 kg/m(2) (mean body mass index, 44.8 +/- 7.4 kg/m(2)) were enrolled in this 52-week, prospective, open-label clinical trial. Endoscopic device implantation was performed with the patient under general anesthesia, and the subjects were examined periodically during the next 52 weeks. Primary end points included changes in fasting blood glucose and insulin levels and changes in hemoglobin A1c (HbA1c). The DJBL was removed endoscopically at the end of the study. Results: Thirteen subjects completed the 52-week study, and the mean duration of the implant period for all subjects was 41.9 +/- 3.2 weeks. Reasons for early removal of the device included device migration (n = 3), gastrointestinal bleeding (n = 1), abdominal pain (n = 2), principal investigator request (n = 2), and discovery of an unrelated malignancy (n = 1). Using last observation carried forward, statistically significant reductions in fasting blood glucose (-30.3 +/- 10.2 mg/dL), fasting insulin (-7.3 +/- 2.6 mu U/mL), and HbA1c (-2.1 +/- 0.3%) were observed. At the end of the study, 16 of the 22 subjects had an HbA1c < 7% compared with only one of 22 at baseline. Upper abdominal pain (n = 11), back pain (n = 5), nausea (n = 7), and vomiting (n = 7) were the most common device-related adverse events. Conclusions: The DJBL improves glycemic status in obese subjects with diabetes and therefore represents a nonsurgical, reversible alternative to bariatric surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoporosis is a global public health that affects postmenopausal women due to the deficiency of estrogen, a hormone that plays an important role in the microarchitecture of bone tissue. Osteoporosis predisposes to pathological bone fracture that can be repaired by conventional methods. However, depending on the severity and quantity of bone loss, the use of autogenous grafts or biomaterials such as hydroxyapatite might be necessary. The latter has received increasing attention in the medical field because of its good biological properties such as osteoconductivity and biocompatibility with bone tissue. The objective of this study was to evaluate using histologic and radiographic analyses, the osteogenic capacity of hydroxyapatite implanted into the femur of rats with ovariectomy-induced osteoporosis. Eighteen rats were divided into three groups with six animals in each: group nonovariectomized, bilaterally ovariectomized not receiving estrogen replacement therapy, and bilaterally ovariectomized submitted to estrogen replacement therapy. Defects were created experimentally in the distal epiphysis of the femur with a surgical drill and filled with porous hydroxyapatite granules. The animals were sacrificed 8 weeks after surgery. The volume of newly formed bone in the implant area was quantified by morphometrical methods. The results were analyzed by ANOVA followed by the Tukey test (P < 0.05). The hydroxyapatite granules showed good radiopacity. Histological analysis revealed less quantity of newly formed bone in the ovariectomized group not submitted to hormone replacement therapy. In conclusion, bone neoformation can be expected even in bones compromised by estrogen deficiency, but the quantity and velocity of bone formation are lower. Microsc. Res. Tech., 2011. (c) 2011 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: to compare acoustic and perceptual parameters regarding the voice of cochlear implanted children, with normal hearing children. Method: this is a cross-sectional, quantitative and qualitative study. Methods: Thirty six cochlear implanted children aged between 3y and 3 m to 5y and 9 m and 25 children with normal hearing, aged between 3y and 11 m and 6y and 6 m, participated in this study. The recordings and the acoustics analysis of the sustained vowel/a/and spontaneous speech were performed using the PRAAT program. The parameters analyzed for the sustained vowel were the mean of the fundamental frequency, jitter, shimmer and harmonic-to-noise ratio (HNR). For the spontaneous speech, the minimum and maximum frequencies and the number of semitones were extracted. The perceptual analysis of the speech material was analyzed using visual-analogical scales of 100 points, composing the aspects related to the overall severity of the vocal deviation, roughness, breathiness, strain, pitch, loudness and resonance deviation, and instability. This last parameter was only analyzed for the sustained vowel. Results: The results demonstrated that the majority of the vocal parameters analyzed in the samples of the implanted children disclosed values similar to those obtained by the group of children with normal hearing. Conclusion: implanted children who participate in a (re) habilitation and follow-up program, can present vocal characteristics similar to those vocal characteristics of children with normal hearing. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

—This paper presents a textile patch antenna designed for WBAN applications at 2.45 GHz ISM band. The antenna uses denim as substrate and conductive fabric for the ground plane and radiator layers. The main purpose of this paper is to analyze the influence of typical deviation of denim properties and patch radiator dimensions on the performance of the antenna. The parameters considered in the analysis are the relative permittivity and thickness of denim and the width and length of the rectangular patch radiator. The dependence of the central operation frequency of the antenna on those parameters was studied using the antenna reflection coefficient obtained from EM simulations. Rules of thumb for one-shot design were derived and applied to design a rectangular patch antenna. An antenna prototype was fabricated and measured, demonstrating a 10 dB impedance band of 4.8 % centered at 2.45 GHz, in good agreement with simulated results

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a new Ultra Wide Band (UWB) Timed- Array Transmitter System with Beamforming capability for high-resolution remote acquisition of vital signals. The system consists of four identical channels, where each is formed of a serial topology with three modules: programmable delay circuit (PDC or τ), a novel UWB 5th Gaussian Derivative order pulse generator circuit (PG), and a planar Vivaldi antenna. The circuit was designed using 0.18μm CMOS standard process and the planar antenna array was designed with filmconductor on Rogers RO3206 substrate. Spice simulations results showed the pulse generation with 104 mVpp amplitude and 500 ps width. The power consumption is 543 μW, and energy consumption 0.27 pJ per pulse using a 2V power supply at a pulse repetition rate (PRR) of 100 MHz. Electromagnetic simulations results, using CST Microwave (MW) Studio 2011, showed the main lobe radiation with a gain maximum of 13.2 dB, 35.5º x 36.7º angular width, and a beam steering between 17º and -11º for azimuthal (θ) angles and 17º and -18º for elevation (φ) angles at the center frequency of 6 GHz