8 resultados para high resolution image

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A high-resolution, multi-proxy record has been used to determine the environmental changes during the Holocene on the southern Brazilian shelf Present oceanographic conditions reveal wind and freshwater input as the determinants of short-term productivity changes in the study area. Magnetic susceptibility and grain-size variations, together with proxies of productivity (organic carbon, carbon accumulation rate, Ba, Sr, and Ca content, Ba/Al, Ba/Ti, and Al/Ti ratios) were analyzed and compared with proxies of redox condition (V/Ti ratio), terrigenous input (Fe/Ca and Ti/Ca ratios), as well as other Element/Ti ratios, to evaluate the paleoceanographic and paleoclimatic changes over the period. The core covers a time interval of about 7650 years, with sedimentation rates varying from 0.025 to 0.250 cm a(-1), which represent time intervals of between 8 and 80 a per sample. There is a clear change in the sedimentation rate at about 2800 B.P. All grain-size and elemental results indicate the occurrence of conspicuous changes between 5200 and 5000 cal. B.P., as well as between 3000 and 2800 cal. B.P. A comparison of the results with the palynological information available from the adjacent continental areas suggests that the sedimentary changes in this last interval may be correlated with the onset of modern climatic conditions in South America, and especially, with the onset of the Plata Plume Water, a water mass that carries cold, less saline waters towards the north. However, minor changes are observed at ca. 1500 B.P. and are correlated with an increase in the atmospheric humidity. Furthermore, a time-series analysis undertaken using several proxies indicated the occurrence of Sub-Milankovitch cycles, which may be compared with those reported worldwide. (C) 2008 Elsevier Ltd and INQUA. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a study of the stellar parameters and iron abundances of 18 giant stars in six open clusters. The analysis was based on high-resolution and high-S/N spectra obtained with the UVES spectrograph (VLT-UT2). The results complement our previous study where 13 clusters were already analyzed. The total sample of 18 clusters is part of a program to search for planets around giant stars. The results show that the 18 clusters cover a metallicity range between -0.23 and +0.23 dex. Together with the derivation of the stellar masses, these metallicities will allow the metallicity and mass effects to be disentangled when analyzing the frequency of planets as a function of these stellar parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report on a boy presenting submucous cleft palate, hydronephrosis, ventriculoseptal defect, aniridia, and developmental delay. Additional material on 11p13 was cytogenetically visible and array analyses identified a duplicated segment on 15q25-26 chromosome region; further, array analyses revealed a small deletion (49?kb) at 11p13 region involving the ELP4 gene and a duplication at 8p23.1. Results were confirmed with both molecular and molecular cytogenetics techniques. Possibilities for etiological basis of clinical phenotype are discussed. (c) 2012 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A computational pipeline combining texture analysis and pattern classification algorithms was developed for investigating associations between high-resolution MRI features and histological data. This methodology was tested in the study of dentate gyrus images of sclerotic hippocampi resected from refractory epilepsy patients. Images were acquired using a simple surface coil in a 3.0T MRI scanner. All specimens were subsequently submitted to histological semiquantitative evaluation. The computational pipeline was applied for classifying pixels according to: a) dentate gyrus histological parameters and b) patients' febrile or afebrile initial precipitating insult history. The pipeline results for febrile and afebrile patients achieved 70% classification accuracy, with 78% sensitivity and 80% specificity [area under the reader observer characteristics (ROC) curve: 0.89]. The analysis of the histological data alone was not sufficient to achieve significant power to separate febrile and afebrile groups. Interesting enough, the results from our approach did not show significant correlation with histological parameters (which per se were not enough to classify patient groups). These results showed the potential of adding computational texture analysis together with classification methods for detecting subtle MRI signal differences, a method sufficient to provide good clinical classification. A wide range of applications of this pipeline can also be used in other areas of medical imaging. Magn Reson Med, 2012. (c) 2012 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Proton nuclear magnetic resonance (H-1 NMR) spectroscopy for detection of biochemical changes in biological samples is a successful technique. However, the achieved NMR resolution is not sufficiently high when the analysis is performed with intact cells. To improve spectral resolution, high resolution magic angle spinning (HR-MAS) is used and the broad signals are separated by a T-2 filter based on the CPMG pulse sequence. Additionally, HR-MAS experiments with a T-2 filter are preceded by a water suppression procedure. The goal of this work is to demonstrate that the experimental procedures of water suppression and T-2 or diffusing filters are unnecessary steps when the filter diagonalization method (FDM) is used to process the time domain HR-MAS signals. Manipulation of the FDM results, represented as a tabular list of peak positions, widths, amplitudes and phases, allows the removal of water signals without the disturbing overlapping or nearby signals. Additionally, the FDM can also be used for phase correction and noise suppression, and to discriminate between sharp and broad lines. Results demonstrate the applicability of the FDM post-acquisition processing to obtain high quality HR-MAS spectra of heterogeneous biological materials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Determination of chlorine using the molecular absorption of aluminum mono-chloride (AlCl) at the 261.418 nm wavelength was accomplished by high-resolution continuum source molecular absorption spectrometry using a transversely heated graphite tube furnace with an integrated platform. For the analysis. 10 mu L of the sample followed by 10 mu L of a solution containing Al-Ag-Sr modifier, (1 g L-1 each), were directly injected onto the platform. A spectral interference due to the use of Al-Ag-Sr as mixed modifier was easily corrected by the least-squares algorithm present in the spectrometer software. The pyrolysis and vaporization temperatures were 500 degrees C and 2200 degrees C, respectively. To evaluate the feasibility of a simple procedure for the determination of chlorine in food samples present in our daily lives, two different digestion methods were applied, namely (A) an acid digestion method using HNO3 only at room temperature, and (B) a digestion method with Ag, HNO3 and H2O2, where chlorine is precipitated as a low-solubility salt (AgCl), which is then dissolved with ammonia solution. The experimental results obtained with method B were in good agreement with the certified values and demonstrated that the proposed method is more accurate than method A. This is because the formation of silver chloride prevented analyte losses by volatilization. The limit of detection (LOD, 3 sigma/s) for Cl in methods A and B was 18 mu g g(-1) and 9 mu g g(-1), respectively, 1.7 and 3.3 times lower compared to published work using inductively coupled plasma optical emission spectrometry, and absolute LODs were 2.4 and 1.2 ng, respectively. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, nighttime light data are suggested as a proxy for spatial distribution of vehicles running in urban and nearby areas. Nighttime lights focus on human activities, in contrast to traditional Earth observing systems that focus on natural systems. It is the human activity being visible in the form of brightness of nocturnal lights. Two available nighttime lights dataset were used in this work. The first one was provided by the U.S. Air Force Defense Meteorological Satellite Program (DMSP) Operational Linescan System (OLS), henceforth, DMSO-OLS. The second one is the NASA-NOAA Suomi National Polar-orbiting Polar-orbiting Partnership (NPP) satellite, henceforth, Suomi-NPP. To validate the new proposed methodology, hundreds of urban areas of South America were analyzed in a high degree of resolution. The results of this study showed that night-time lights are very well correlated with vehicle fleet, population, and impervious surfaces but with strong spatial variability. The results of this study suggest a better understanding of the human activities in the context of a vehicular-based city conception.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a new Ultra Wide Band (UWB) Timed- Array Transmitter System with Beamforming capability for high-resolution remote acquisition of vital signals. The system consists of four identical channels, where each is formed of a serial topology with three modules: programmable delay circuit (PDC or τ), a novel UWB 5th Gaussian Derivative order pulse generator circuit (PG), and a planar Vivaldi antenna. The circuit was designed using 0.18μm CMOS standard process and the planar antenna array was designed with filmconductor on Rogers RO3206 substrate. Spice simulations results showed the pulse generation with 104 mVpp amplitude and 500 ps width. The power consumption is 543 μW, and energy consumption 0.27 pJ per pulse using a 2V power supply at a pulse repetition rate (PRR) of 100 MHz. Electromagnetic simulations results, using CST Microwave (MW) Studio 2011, showed the main lobe radiation with a gain maximum of 13.2 dB, 35.5º x 36.7º angular width, and a beam steering between 17º and -11º for azimuthal (θ) angles and 17º and -18º for elevation (φ) angles at the center frequency of 6 GHz