10 resultados para high optical-to-optical conversion efficiency

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The success of magnetic hyperthermia cancer treatments rely strongly on the magnetic properties of the nanoparticles and their intricate dependence on the externally applied field. This is particularly more so as the response departs from the low field linear regime. In this paper we introduce a new parameter, referred to as the efficiency in converting electromagnetic energy into thermal energy, which is shown to be remarkably useful in the analysis of the system response, especially when the power loss is investigated as a function of the applied field amplitude. Using numerical simulations of dynamic hysteresis, through the stochastic Landau-Lifshitz model, we map in detail the efficiency as a function of all relevant parameters of the system and compare the results with simple-yet powerful-predictions based on heuristic arguments about the relaxation time. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4705392]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article aims to develop and implement a search tool which, through the perception of its respondents, allows assessing how eco-efficient an organization is based on the identification of delivery levels of support competencies to organizational eco-efficiency. A mixed (qualitative and quantitative) exploratory-descriptive research was conducted, from a case study in an 'ISE Company'. A semi-structured interview and pictures of verification were used as data collection instruments. The data were analyzed via documentary analysis and triangulation of information collected. It was inferred that at the 'ISE Company' professionals at the high-level of the organizational hierarchy recognize, in part, the growth of organizational actions that contribute to sustainability, which is not fully consistent with national publications on the subject. The result of the research showed that organizational strategies addressing eco-efficiency are partially aligned with the professional performance of the organization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This study evaluated the effects of a protocol aiming to reduce hypotension in acute kidney injury (AKI) patients submitted to sustained low-efficiency dialysis (SLED). Methods: Patients were randomly assigned to two SLED prescriptions-control group, dialysate temperature was 37.0 degrees C with a fixed sodium concentration [138 mEq/L] and ultrafiltration (UF) rate; and profiling group, dialysate temperature was 35.5 degrees C with a variable sodium concentration [150-138 mEq/L] and UF rate. Results: Sixty-two SLED sessions were evaluated (34 in profiling and 28 in control). Patients (n = 31) were similar in terms of gender, age, and Sequential Organ Failure Assessment (SOFA) score. Dialysis time, dialysis dose, and post-dialysis serum sodium were similar in both groups. The profiling group had significantly less hypotension episodes (23% vs. 57% in control, p = 0.009) and achieved higher UF volume (2.23 +/- 1.25 L vs. 1.59 +/- 1.03 L in control, p = 0.04) when compared with control group. Conclusions: SLED protocol with modulation of dialysate temperature, sodium, and UF profiling showed similar efficacy but less intradialytic hypotension when compared with a standard SLED prescription.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eucalyptus plantations occupy almost 20 million ha worldwide and exceed 3.7 million ha in Brazil alone. Improved genetics and silviculture have led to as much as a three-fold increase in productivity in Eucalyptus plantations in Brazil and the large land area occupied by these highly productive ecosystems raises concern over their effect on local water supplies. As part of the Brazil Potential Productivity Project, we measured water use of Eucalyptus grandis x urophylla clones in rainfed and irrigated stands in two plantations differing in productivity. The Aracruz (lower productivity) site is located in the state of Espirito Santo and the Veracel (higher productivity) site in Bahia state. At each plantation, we measured stand water use using homemade sap flow sensors and a calibration curve using the clones and probes we utilized in the study. We also quantified changes in growth, leaf area and water use efficiency (the amount of wood produced per unit of water transpired). Measurements were conducted for 1 year during 2005 at Aracruz and from August through December 2005 at Veracel. Transpiration at both sites was high compared to other studies but annual estimates at Aracruz for the rainfed treatment compared well with a process model calibrated for the Aracruz site (within 10%). Annual water use at Aracruz was 1394 mm in rainfed treatments versus 1779 mm in irrigated treatments and accounted for approximately 67% and 58% of annual precipitation and irrigation inputs respectively. Increased water use in the irrigated stands at Aracruz was associated with higher sapwood area, leaf area index and transpiration per unit leaf area but there was no difference in the response of canopy conductance with air saturation deficit between treatments. Water use efficiency at the Aracruz site was also not influenced by irrigation and was similar to the rainfed treatment. During the period of overlapping measurements, the response to irrigation treatments at the more productive Veracel site was similar to Aracruz. Stand water use at the Veracel site totaled 975 mm and 1102 mm in rainfed and irrigated treatments during the 5-month measurement period respectively. Irrigated stands at Veracel also had higher leaf area with no difference in the response of canopy conductance with air saturation deficit between treatments. Water use efficiency was also unaffected by irrigation at Veracel. Results from this and other studies suggest that improved resource availability does not negatively impact water use efficiency but increased productivity of these plantations is associated with higher water use and should be given consideration during plantation management decision making processes aimed at increasing productivity. Published by Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The nanotechnology, through encapsulation of active ingredients, has showed an important way to avoid problems with quickly degradation of the pesticide molecules. Thus, neem (Azadirachta indica) oil nanoformulations containing beta-ciclodextrin and poli-epsilon-caprolactone (PCL) were tested as to their control efficiency against eggs and nymphs of Bemisia tabaci (Genn.) biotype B reared in soybean. The Lethal Concentration (LC50) was estimated using a commercial neem oil (Organic Neem (R)) on first-instar nymphs to establish the adequate volume of the nanoformulations per treatment. After that, they were sprayed on eggs and first-instar nymphs in laboratory and greenhouse and on third-instar nymphs in greenhouse. The commercial neem oil and distilled water were used as controls. Egg viability was not affected by any treatment. Among six nanoformulations, only one was efficient against the first-instar nymphs in laboratory conditions. However, its effective period was not increased as expected. In greenhouse, first-instar nymphs were more affected by two nanoformulations which were significantly different of the commercial neem oil - the most effective one. No mortality differences among the formulations in the third-instar test were observed. The nanoformulations were less efficient to control the B. tabaci biotype B nymphs than the commercial neem oil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies have shown that platelet APP ratio (representing the percentage of 120-130 kDa to 110 kDa isoforms of the amyloid precursor protein) is reduced in patients with mild cognitive impairment (MCI) and Alzheimer's disease (AD). In the present study, we sought to determine if baseline APP ratio predicts the conversion from MCI to AD dementia after 4 years of longitudinal assessment. Fifty-five older adults with varying degrees of cognitive impairment (34 with MCI and 21 with AD) were assessed at baseline and after 4 years. MCI patients were re-classified according to the conversion status upon follow-up: 25 individuals retained the diagnostic status of MCI and were considered as stable cases (MCI-MCI); conversely, in nine cases the diagnosis of dementia due to AD was ascertained. The APP ratio (APPr) was determined by the Western blot method in samples of platelets collected at baseline. We found a significant reduction of APPr in MCI patients who converted to dementia upon follow-up. These individuals had baseline APPr values similar to those of demented AD patients. The overall accuracy of APPr to identify subjects with MCI who will progress to AD was 0.74 +/- A 0.10, p = 0.05. The cut-off of 1.12 yielded a sensitivity of 75 % and a specificity of 75 %. Platelet APPr may be a surrogate marker of the disease process in AD, with potential implications for the assessment of abnormalities in the APP metabolism in patients with and at risk for dementia. However, diagnostic accuracy was relatively low. Therefore, studies in larger samples are needed to determine whether APPr may warrant its use as a biomarker to support the early diagnosis of AD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An exact expression is derived for the time-averaged electromagnetic energy within a magneto-dielectric coated sphere, which is irradiated by a plane and time-harmonic electromagnetic wave. Both the spherical shell and core are considered to be dispersive and lossy, with a realistic dispersion relation of an isotropic split-ring resonator metamaterial. We obtain analytical expressions for the stored electromagnetic energies inside the core and the shell separately and calculate their contributions to the total average energy density. The stored electromagnetic energy is calculated for two situations involving a metamaterial coated sphere: a dielectric shell and dispersive metamaterial core, and vice versa. An explicit relation between the stored energy and the optical absorption efficiency is also obtained. We show that the stored electromagnetic energy is an observable sensitive to field interferences responsible for the Fano effect. This result, together with the fact that the Fano effect is more likely to occur in metamaterials with negative refraction, suggest that our findings may be explored in applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To analyze the efficiency of high voltage pulsed current (HVPC) with early application in three different sites, in the regeneration of the sciatic nerve in rats submitted to crush injury, the sciatic functional index (SFI) was used to assess the functional recovery. Methods: After crushing of the nerve, 57 animals were submitted to cathodal HVPC at frequency of 50Hz and voltage of 100V, 20 minutes per day, 5 days per week. The rats were divided into five groups: control group; ganglion group; ganglion + muscle group; muscle group; and sham group. The SFI was determined weekly for seven weeks, from the preoperative period to the 6th postoperative week. Results: Compared with the control group, the results showed a significantly better performance of group 2 for the first 3 weeks; group 3 showed significantly better performance in the third week; and group 4 showed a significantly negative performance during the 481 and 6th weeks. Conclusion: Early application of HVPC had a positive effect in the treatment of the spinal cord region and the sciatic nerve root ganglion with a dispersive electrode on the contralateral lumbar region or on the gastrocnemius. However, HVPC had a negative effect in the treatment with an active electrode on the gastrocnemius and a dispersive electrode on the contralateral thigh. Level of evidence II, Prospective comparative study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Further advances in magnetic hyperthermia might be limited by biological constraints, such as using sufficiently low frequencies and low field amplitudes to inhibit harmful eddy currents inside the patient's body. These incite the need to optimize the heating efficiency of the nanoparticles, referred to as the specific absorption rate (SAR). Among the several properties currently under research, one of particular importance is the transition from the linear to the non-linear regime that takes place as the field amplitude is increased, an aspect where the magnetic anisotropy is expected to play a fundamental role. In this paper we investigate the heating properties of cobalt ferrite and maghemite nanoparticles under the influence of a 500 kHz sinusoidal magnetic field with varying amplitude, up to 134 Oe. The particles were characterized by TEM, XRD, FMR and VSM, from which most relevant morphological, structural and magnetic properties were inferred. Both materials have similar size distributions and saturation magnetization, but strikingly different magnetic anisotropies. From magnetic hyperthermia experiments we found that, while at low fields maghemite is the best nanomaterial for hyperthermia applications, above a critical field, close to the transition from the linear to the non-linear regime, cobalt ferrite becomes more efficient. The results were also analyzed with respect to the energy conversion efficiency and compared with dynamic hysteresis simulations. Additional analysis with nickel, zinc and copper-ferrite nanoparticles of similar sizes confirmed the importance of the magnetic anisotropy and the damping factor. Further, the analysis of the characterization parameters suggested core-shell nanostructures, probably due to a surface passivation process during the nanoparticle synthesis. Finally, we discussed the effect of particle-particle interactions and its consequences, in particular regarding discrepancies between estimated parameters and expected theoretical predictions. Copyright 2012 Author(s). This article is distributed under a Creative Commons Attribution 3.0 Unported License. [http://dx.doi. org/10.1063/1.4739533]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite considerable research conducted on 'Tahiti' lime [Citrus latifolia (Yu Tanaka) Tanaka] in several countries, few long-term studies have focused on rootstock effects on fruit production and quality under non-irrigated conditions. As for many other fruit crops, rootstock studies for 'Tahiti' lime are often based on the evaluation of several horticultural responses simultaneously, instead of considering multivariate statistical approaches which may provide with more comprehensive information. Consequently, a trial was installed to evaluate the horticultural performance of non-irrigated 'Tahiti' lime trees budded onto the following 12 rootstocks: 'HRS 801' and 'HRS 827' hybrids; 'Rubidoux', 'FCAV' and 'Flying Dragon' trifoliates; 'Sun Chu Sha Kat' and 'Sunki' mandarins; 'Cravo Limeira' and 'Cravo FCAV' 'Rangpur' limes; 'Carrizo' citrange, 'Swingle' citrumelo, and 'Orlando' tangelo. The trial was installed in 2001, in an 8 m x 5 m spacing with no supplementary irrigation. Measurements of yield, fruit quality oriented to different consuming markets, canopy volume and tree tolerance to drought, were performed. A multivariate cluster analysis identified both 'Rangpur' lime rootstocks as those inducing larger cumulative yield and higher percentage of fruits for the domestic market, with highest drought tolerance to the trees. Despite of their high susceptibility to drought stress under non-irrigated conditions, the 'Flying Dragon' and 'FCAV' trifoliate rootstocks performed outstandingly for 'Tahiti' lime, inducing higher yield efficiency, early bearing and larger percentage of high-quality fruits for foreign markets, with smaller trees more suitable for high-density plantings. (c) 2012 Elsevier B.V. All rights reserved.