9 resultados para grating acuity
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Background: This study measured grating visual acuity in 173 children between 6-48 months of age who had different types of spastic cerebral palsy (CP). Method: Behavioural acuity was measured with the Teller Acuity Cards (TAC) using a staircase psychophysical procedure. Electrophysiological visual acuity was estimated using the sweep VEP (sVEP). Results: The percentage of children outside the superior tolerance limits was 44 of 63 (69%) and 50 of 55 (91%) of tetraplegic, 36 of 56 (64%) and 42 of 53 (79%) of diplegic, 10 of 48 (21%) and 12 of 40 (30%) of hemiplegic for sVEP and TAC, respectively. For the sVEP, the greater visual acuity deficit found in the tetraplegic group was significantly different from that of the hemiplegic group (p < 0.001). In the TAC procedure the mean visual acuity deficits of the tetraplegic and diplegic groups were significantly different from that of hemiplegic group (p < 0.001). The differences between sVEP and TAC means of visual acuity difference were statistically significant for the tetraplegic (p < 0.001), diplegic (p < 0.001), and hemiplegic group (p = 0.004). Discussion: Better visual acuities were obtained in both procedures for hemiplegic children compared to diplegic or tetraplegic. Tetraplegic and diplegic children showed greater discrepancies between the TAC and sVEP results. Inter-ocular acuity difference was more frequent in sVEP measurements. Conclusions: Electrophysiologically measured visual acuity is better than behavioural visual acuity in children with CP.
Resumo:
Objective: To review the clinical characteristics of patients with neuromyelitis optica (NMO) and to compare their visual outcome with those of patients with optic neuritis (ON) and multiple sclerosis (MS). Methods: Thirty-three patients with NMO underwent neuro-ophthalmic evaluation, including automated perimetry along with 30 patients with MS. Visual function in both groups was compared overall and specifically for eyes after a single episode of ON. Results: Visual function and average visual field (VF) mean deviation were significantly worse in eyes of patients with NMO. After a single episode of ON, the VF was normal in only 2 of 36 eyes of patients with NMO compared to 17 of 35 eyes with MS (P < 0.001). The statistical analysis indicated that after a single episode of ON, the odds ratio for having NMO was 6.0 (confidence interval [CI]: 1.6-21.9) when VF mean deviation was worse than -20.0 dB while the odds ratio for having MS was 16.0 (CI: 3.6-68.7) when better than -3.0 dB. Conclusion: Visual outcome was significantly worse in NMO than in MS. After a single episode of ON, suspicion of NMO should be raised in the presence of severe residual VF deficit with automated perimetry and lowered in the case of complete VF recovery.
Resumo:
Organic-inorganic hybrids containing methacrylic acid (McOH, CH(2)= C(CH(3))COOH)) modified zirconium tetrapropoxide, Zr(OPr(n))(4), classed as di-ureasil-zirconium oxo-cluster hybrids, have been prepared and structurally characterized by X-ray diffraction (XRD), small-angle X-ray scattering (SAXS), Fourier transform infrared (FT-IR) and Raman (FT-Raman) spectroscopies, Si and C nuclear magnetic resonance (NMR), and atomic force microscopy (AFM). XRD and SAXS results have pointed out the presence of Si- and Zr-based nanobuilding blocks (NBBs) dispersed into the organic phase. Inter-NBBs correlation distances have been estimated for the pure di-ureasil and a model compound obtained. by hydrolysis/condensation of Zr(OPr(n))(4):McOH (molar ratio 1: 1): d(Si) approximate to 26 +/- 1 angstrom and d(Zr) approximate to 16 +/- 1 angstrom, respectively. In the case of the di-ureasil-zirconium oxo-cluster hybrids, these distances depend on the Zr relative molar percentage (rel. mol. Zr %) (d(Si) ranges from 18 to 25 angstrom and d(Zr) from 14 to 23 angstrom, as the rel. mol. Zr % increases from 5 to 75), suggesting that the Si- and Zr-based clusters are interconstrained. Complementary data from FT-IR, FT-Raman, (29)Si and (13)C NMR, and AFM support to a structural model where McOH-modified Zr-based NBBs (Zr-OMc) are present over the whole range of composition. At low Zr-OMc contents (rel. mol. Zr % <30) the clusters are well-dispersed within the di-ureasil host, whereas segregation occurs at the 0.1 mu m scale at high Zr-OMc concentration (rel. mol. Zr % = 50). No Zr-O-Si heterocondensation has been discerned. Monomode waveguides, diffractions gratings, and Fabry-Perot cavities have been written through the exposure of the hybrid monoliths to UV light. FT-Raman has shown that the chemical process that takes place under illumination is the polymerization of the methacrylate groups of the Zr-OMc NBBs. The guidance region in patterned channels is a Gaussian section located below the exposed surface with typical dimensions of 320 mu m wide and 88 mu m deep. The effective refractive index is 1.5162 (maximum index contrast on the order of 1 x 10(-4)) and the reflection coeficient of the Fabry-Perot cavity (formed by a grating patterned into a 0.278 cm channel) is 0.042 with a free spectral range value of 35.6 GHz.
Resumo:
Stereoscopic depth perception utilizes the disparity cues between the images that fall on the retinae of the two eyes. The purpose of this study was to determine what role aging and optical blur play in stereoscopic disparity sensitivity for real depth stimuli. Forty-six volunteers were tested ranging in age from 15 to 60 years. Crossed and uncrossed disparity thresholds were measured using white light under conditions of best optical correction. The uncrossed disparity thresholds were also measured with optical blur (from +1.0D to +5.0D added to the best correction). Stereothresholds were measured using the Frisby Stereo Test, which utilizes a four-alternative forced-choice staircase procedure. The threshold disparities measured for young adults were frequently lower than 10 arcsec, a value considerably lower than the clinical estimates commonly obtained using Random Dot Stereograms (20 arcsec) or Titmus Fly Test (40 arcsec) tests. Contrary to previous reports, disparity thresholds increased between the ages of 31 and 45 years. This finding should be taken into account in clinical evaluation of visual function of older patients. Optical blur degrades visual acuity and stereoacuity similarly under white-light conditions, indicating that both functions are affected proportionally by optical defocus.
Resumo:
Contrast sensitivity (CS) was evaluated in 41 former workers from a lamp manufacturing plant who were on disability retirement due to exposure to mercury and 14 age-matched controls. The CS was measured monocularly using the sweep visual evoked potential (sVEP) paradigm at 6 spatial frequencies (0.2, 0.8, 2.0, 4.0, 15.0, and 30 cpd). Statistical difference (p < 0.05) was found between the controls and the patient right and left eyes for 2.0 and 4.0 cpd. According the results in those spatial frequencies the eyes were classified in best and worst. Statistical differences were found between the controls and the best eyes for 2.0 and 4.0 cpd and for 0.8, 2.0, and 4.0 cpd for their worst eyes. No correlation was found between CS results and the time of exposure (mean 8.9 yr +/- 4.1), time away from the mercury source (mean = 6.0 yr +/- 3.9), urinary mercury level at the time of work (mean = 40.6 mu g/g +/-36.3) or with the mercury level at the CS measurement time (mean = 1.6 mu g/g +/-1.1). We show the first evidence of a permanent impairment in CS measured objectively with the sVEP. Our data complement the previous psychophysical works reporting a diffuse impairment in the CS function showing a CS reduction in the low to middle spatial frequencies. In conclusion, non-reversible CS impairment was found in occupational exposure to mercury vapor. We suggest that CS measurement should be included in studies of the mercury effects of occupational exposure. (C) 2007 Elsevier Inc. All rights reserved.
Resumo:
Amazonian gold mining activity results in human exposure to mercury vapor. We evaluated the visual system of two Amazonian gold miners (29 and 37 years old) by recording the transient pattern electroretinogram (tPERG) and transient pattern visual evoked potential (tPVEP). We compared these results with those obtained from a regional group of control subjects. For both tPERG and tPVEP, checkerboards with 0.5 or 2 cycles per degree (cpd) of spatial frequency were presented in a 16 degrees squared area, 100% Michelson contrast, 50cd/m(2) mean luminance, and 1 Hz square-wave pattern-reversal presentation. Two averaged waveforms (n = 240 sweeps, Is each) were monocularly obtained for each subject in each condition. Both eyes were monocularly tested only in gold miners. Normative data were calculated using a final pooled waveforin with 480 sweeps. The first gold miner, LCS, had normal tPERG responses. The second one, RNP, showed low tPERG (P50 component) amplitudes at 0.5cpd for both eyes, outside the normative data, and absence of response at 2 cpd for his right eye. Delayed tPVEP responses (P 100 component) were found at 2 cpd for LCS but the implicit times were inside the normative data. Subject RNP also showed delayed tPVEP responses (all components), but only the implicit time obtained with his right eye was outside the normative data at 2cpd. We conclude that mercury exposure levels found in the Amazon gold miners is high enough to damage the visual system and can be assessed by non-invasive electrophysiological techniques. (C) 2007 Elsevier Inc. All rights reserved.
Resumo:
There are several electrophysiological systems available commercially. Usually, control groups are required to compare their results, due to the differences between display types. Our aim was to examine the differences between CRT and LCD/TFT stimulators used in pattern VEP responses performed according to the ISCEV standards. We also aimed to check different contrast values toward thresholds. In order to obtain more precise results, we intended to measure the intensity and temporal response characteristics of the monitors with photometric methods. To record VEP signals, a Roland RetiPort electrophysiological system was used. The pattern VEP tests were carried out according to ISCEV protocols on a CRT and a TFT monitor consecutively. Achromatic checkerboard pattern was used at three different contrast levels (maximal, 75, 25%) using 1A degrees and 15` check sizes. Both CRT and TFT displays were luminance and contrast matched, according to the gamma functions based on measurements at several DAC values. Monitor-specific luminance parameters were measured by means of spectroradiometric instruments. Temporal differences between the displays` electronic and radiometric signals were measured with a device specifically built for the purpose. We tested six healthy control subjects with visual acuity of at least 20/20. The tests were performed on each subject three times on different days. We found significant temporal differences between the CRT and the LCD monitors at all contrast levels and spatial frequencies. In average, the latency times were 9.0 ms (+/- 3.3 ms) longer with the TFT stimulator. This value is in accordance with the average of the measured TFT input-output temporal difference values (10.1 +/- A 2.2 ms). According to our findings, measuring the temporal parameters of the TFT monitor with an adequately calibrated measurement setup and correcting the VEP data with the resulting values, the VEP signals obtained with different display types can be transformed to be comparable.
Resumo:
PURPOSE: To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING: Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil. DESIGN: Prospective randomized double-masked comparative clinical trial. METHODS: One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS: Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION: Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal +3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add.
Resumo:
PURPOSE. To evaluate electrically evoked phosphene thresholds (EPTs) in healthy subjects and in patients with retinal disease and to assess repeatability and possible correlations with common ophthalmologic tests. METHODS. In all, 117 individuals participated: healthy subjects (n = 20) and patients with retinitis pigmentosa (RP, n = 30), Stargardt's disease (STG, n = 14), retinal artery occlusion (RAO, n = 20), nonarteritic anterior ischemic optic neuropathy (NAION, n = 16), and primary open-angle glaucoma (POAG, n = 17). EPTs were determined at 3, 6, 9, 20, 40, 60, and 80 Hz with 5+5-ms biphasic current pulses using DTL electrodes. Subjects were examined twice (test-retest range: 1-6 weeks). An empirical model was developed to describe the current-frequency relationship of EPTs. Visual acuity, visual field (kinetic + static), electrophysiology (RP, RAO, STG: Ganzfeld-electroretinography [ERG]/multifocal-ERG; POAG: pattern-ERG; NAION: VEP), slit-lamp biomicroscopy, fundus examination, and tonometry were assessed. RESULTS. EPTs varied between disease groups (20 Hz: healthy subjects: 0.062 +/- 0.038 mA; STG: 0.102 +/- 0.097 mA; POAG: 0.127 +/- 0.09 mA; NAION: 0.244 +/- 0.126 mA; RP: 0.371 +/- 0.223 mA; RAO: 0.988 +/- 1.142 mA). In all groups EPTs were lowest at 20 Hz. In patients with retinal diseases and across all frequencies EPTs were significantly higher than those in healthy subjects, except in STG at 20 Hz (P = 0.09) and 40 Hz (P = 0.17). Test-retest difference at 20 Hz was 0.006 mA in the healthy group and 0.003-0.04 mA in disease groups. CONCLUSIONS. Considering the fast, safe, and reliable practicability of EPT testing, this test might be used more often under clinical circumstances. Determination of EPTs could be potentially useful in elucidation of the progress of ophthalmologic diseases, either in addition to standard clinical assessment or under conditions in which these standard tests cannot be used meaningfully. (ClinicalTrials.gov number, NCT00804102.) (Invest Ophthalmol Vis Sci. 2012; 53: 7440-7448) DOI:10.1167/iovs.12-9612