4 resultados para gated-controlled lateral phototransistor

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To evaluate the effect of insertion torque on micromotion to a lateral force in three different implant designs. Material and methods: Thirty-six implants with identical thread design, but different cutting groove design were divided in three groups: (1) non-fluted (no cutting groove, solid screw-form); (2) fluted (901 cut at the apex, tap design); and (3) Blossomt (Patent pending) (non-fluted with engineered trimmed thread design). The implants were screwed into polyurethane foam blocks and the insertion torque was recorded after each turn of 901 by a digital torque gauge. Controlled lateral loads of 10N followed by increments of 5 up to 100N were sequentially applied by a digital force gauge on a titanium abutment. Statistical comparison was performed with two-way mixed model ANOVA that evaluated implant design group, linear effects of turns and displacement loads, and their interaction. Results: While insertion torque increased as a function of number of turns for each design, the slope and final values increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- standard deviation [SD] = 64.1 +/- 26.8, 139.4 +/- 17.2, and 205.23 +/- 24.3 Ncm, respectively). While a linear relationship between horizontal displacement and lateral force was observed for each design, the slope and maximal displacement increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- SD 530 +/- 57.7, 585.9 +/- 82.4, and 782.33 +/- 269.4 mm, respectively). There was negligible to moderate levels of association between insertion torque and lateral displacement in the Blossomt, fluted and non-fluted design groups, respectively. Conclusion: Insertion torque was reduced in implant macrodesigns that incorporated cutting edges, and lesser insertion torque was generally associated with decreased micromovement. However, insertion torque and micromotion were unrelated within implant designs, particularly for those designs showing the least insertion torque.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To test the null hypothesis: Subjects with isolated complete unilateral cleft lip and palate (UCLP) show no differences in overall frequency of tooth agenesis (hypodontia), comparing a subsample with cleft-side maxillary lateral incisor (MxI2) agenesis to a subsample without cleftside MxI2 agenesis. Findings could clarify the origins of cleft-side MxI2 agenesis. Materials and Methods: Tooth agenesis was identified from dental radiographs of 141 subjects with UCLP. The UCLP cohort was segregated into four categories according to the status and location of MxI2 in the region of the unilateral cleft: group M: subjects with one tooth, located on the mesial side of the alveolar cleft; group D: subjects with one tooth, located on the distal side of the alveolar cleft; group MD: subjects with two teeth present, one mesial and one distal to the cleft; and group ABS: subjects with lateral incisor absent (agenesis) in the cleft area. Results: The null hypothesis was rejected. Among UCLP subjects, there was a twofold increase (P < .0008) in overall frequency of tooth agenesis outside the cleft region in a subsample with cleftside MxI2 agenesis (ABS), compared to a subsample presenting with no agenesis of the cleft-side MxI2 (M+D+MD). Conclusions: Cleft-side MxI2 agenesis in CLP subjects appears to be largely a genetically controlled anomaly associated with cleft development, rather than a collateral environmental consequence of the adjacent cleft defect, since increased hypodontia involving multiple missing teeth observed remote from a cleft clearly has a significant genetic basis. (Angle Orthod. 2012;82:959-963.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Legg-Calv,-Perthes (LCP) disease is currently managed by mechanical containment of the femoral head in the hip socket. As evidence suggests that hip distraction may offer a new treatment strategy, we used arthrodistraction as a primary treatment for active forms of LCP disease and prospectively compared the results with the Salter innominate osteotomy. A total of 54 children, six years or older of both genders with severe forms of LCP disease in the stages of necrosis or revascularisation, were enrolled. Patients were submitted to either Salter innominate osteotomy (n = 28) or hip arthrodistraction (n = 26). Final radiographs were used to evaluate the Mose index, Wiberg angle, extrusion index and the Stulberg et al. classification. There were no significant differences in gender, age, lateral pillar classification and average follow-up time between the two groups. The osteotomy group progressed without major complications, but children in the joint distraction group experienced episodes of pin tract pain and infection, leading to the early removal of the external device in one case. Two patients developed joint stiffness, treated by physiotherapy or manipulation, and one child developed subluxation of the femoral head. The average time in distraction was 4.44 months (2.53-7.23 months). In the final evaluation the osteotomy group showed better containment of the femoral head. The Mose index and the Stulberg et al. classification were statistically similar between the two groups. Despite similar final radiological results, arthrodistraction was associated with a higher morbidity. Consequently, we do not recommend hip distraction as a primary treatment for the early stages of LCP disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background Recent reviews have indicated that low level level laser therapy (LLLT) is ineffective in lateral elbow tendinopathy (LET) without assessing validity of treatment procedures and doses or the influence of prior steroid injections. Methods Systematic review with meta-analysis, with primary outcome measures of pain relief and/or global improvement and subgroup analyses of methodological quality, wavelengths and treatment procedures. Results 18 randomised placebo-controlled trials (RCTs) were identified with 13 RCTs (730 patients) meeting the criteria for meta-analysis. 12 RCTs satisfied half or more of the methodological criteria. Publication bias was detected by Egger's graphical test, which showed a negative direction of bias. Ten of the trials included patients with poor prognosis caused by failed steroid injections or other treatment failures, or long symptom duration or severe baseline pain. The weighted mean difference (WMD) for pain relief was 10.2 mm [95% CI: 3.0 to 17.5] and the RR for global improvement was 1.36 [1.16 to 1.60]. Trials which targeted acupuncture points reported negative results, as did trials with wavelengths 820, 830 and 1064 nm. In a subgroup of five trials with 904 nm lasers and one trial with 632 nm wavelength where the lateral elbow tendon insertions were directly irradiated, WMD for pain relief was 17.2 mm [95% CI: 8.5 to 25.9] and 14.0 mm [95% CI: 7.4 to 20.6] respectively, while RR for global pain improvement was only reported for 904 nm at 1.53 [95% CI: 1.28 to 1.83]. LLLT doses in this subgroup ranged between 0.5 and 7.2 Joules. Secondary outcome measures of painfree grip strength, pain pressure threshold, sick leave and follow-up data from 3 to 8 weeks after the end of treatment, showed consistently significant results in favour of the same LLLT subgroup (p < 0.02). No serious side-effects were reported. Conclusion LLLT administered with optimal doses of 904 nm and possibly 632 nm wavelengths directly to the lateral elbow tendon insertions, seem to offer short-term pain relief and less disability in LET, both alone and in conjunction with an exercise regimen. This finding contradicts the conclusions of previous reviews which failed to assess treatment procedures, wavelengths and optimal doses.