2 resultados para failure stability

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Heart failure (HF) is associated with poor prognosis, and the identification of biomarkers of its severity could help in its treatment. In a pilot study, we observed high levels of acetone in the exhaled breath of patients with HF. The present study was designed to evaluate exhaled acetone as a biomarker of HF diagnosis and HF severity. Methods: Of 235 patients with systolic dysfunction evaluated between May 2009 and September 2010, 89 patients (HF group) fulfilled inclusion criteria and were compared with sex- and age-matched healthy subjects (control group, n = 20). Patients with HF were grouped according to clinical stability (acute decompensated HF [ADHF], n = 59; chronic HF, n = 30) and submitted to exhaled breath collection. Identification of chemical species was done by gas chromatography-mass spectrometry and quantification by spectrophotometry. Patients with diabetes were excluded. Results: The concentration of exhaled breath acetone (EBA) was higher in the HF group (median, 3.7 mu g/L; interquartile range [IQR], 1.69-10.45 mu g/L) than in the control group (median, 0.39 mu g/L; IQR, 0.30-0.79 mu g/L; P < .001) and higher in the ADHF group (median, 7.8 mu g/L; IQR, 3.6-15.2 mu g/L) than in the chronic HF group (median, 1.22 mu g/L; IQR, 0.68-2.19 P < .001). The accuracy and sensitivity of this method in the diagnosis of HF and ADHF were about 85%, a value similar to that obtained with B-type natriuretic peptide (BNP). EBA levels differed significantly as a function of severity of HF (New York Heart Association classification, P < .001). There was a positive correlation between EBA and BNP (r = 0.772, P < .001). Conclusions: EBA not only is a promising noninvasive diagnostic method of HF with an accuracy equivalent to BNP but also a new biomarker of HF severity. CHEST 2012; 142(2):457-466

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose of this study was to evaluate the influence of miniscrew dental root proximity on its late stability degree. 40 miniscrews were inserted between maxillary second premolars and first molars for anterior retraction. Post-surgical radiographs were used to measure the septum width in the insertion site, insertion height, distal and mesial distance from miniscrew to dental root, and the smallest distance between miniscrew and dental root. The miniscrews were divided in two groups according to septum width: ?3 mm (20 miniscrews) and >3 mm (20 miniscrews). The soft tissue in the insertion site, sensitivity during load, plaque around the miniscrew, and evaluation period were also considered. The results showed no significant difference in miniscrew mobility degree and success rate between groups. Miniscrew dental root proximity did not influence the stability and success rate when the distance between the miniscrew and dental root indicated no periodontal ligament invasion. The overall success rate was 90% and no variable was associated with miniscrew failure. Nevertheless, patient sensitivity was frequently associated with some degree of mini-implant mobility. The septum width did not influence the stability and success rate of this anchorage system, but the extreme root proximity did.