5 resultados para donor specific transfusion

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The significance of pretransplant, donor-specific antibodies on long-term patient outcomes is a subject of debate. This study evaluated the impact and the presence or absence of donor-specific antibodies after kidney transplantation on short-and long-term graft outcomes. METHODS: We analyzed the frequency and dynamics of pretransplant donor-specific antibodies following renal transplantation from a randomized trial that was conducted from 2002 to 2004 and correlated these findings with patient outcomes through 2009. Transplants were performed against a complement-dependent T-and B-negative crossmatch. Pre- and posttransplant sera were available from 94 of the 118 patients (80%). Antibodies were detected using a solid-phase (Luminex (R)), single-bead assay, and all tests were performed simultaneously. RESULTS: Sixteen patients exhibited pretransplant donor-specific antibodies, but only 3 of these patients (19%) developed antibody-mediated rejection and 2 of them experienced early graft losses. Excluding these 2 losses, 6 of 14 patients exhibited donor-specific antibodies at the final follow-up exam, whereas 8 of these patients (57%) exhibited complete clearance of the donor-specific antibodies. Five other patients developed "de novo'' posttransplant donor-specific antibodies. Death-censored graft survival was similar in patients with pretransplant donor-specific and non-donor-specific antibodies after a mean follow-up period of 70 months. CONCLUSION: Pretransplant donor-specific antibodies with a negative complement-dependent cytotoxicity crossmatch are associated with a risk for the development of antibody-mediated rejection, although survival rates are similar when patients transpose the first months after receiving the graft. Our data also suggest that early posttransplant donor-specific antibody monitoring should increase knowledge of antibody dynamics and their impact on long-term graft outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: In Brazil nationally representative donor data are limited on human immunodeficiency virus (HIV) prevalence, incidence, and residual transfusion risk. The objective of this study was to analyze HIV data obtained over 24 months by the Retrovirus Epidemiology Donor Study-II program in Brazil. STUDY DESIGN AND METHODS: Donations reactive to third-and fourth-generation immunoassays (IAs) were further confirmed by a less-sensitive (LS) IA algorithm and Western blot (WB). Incidence was calculated for first-time (FT) donors using the LS-EIA results and for repeat donors with a model developed to include all donors with a previous negative donation. Residual risk was projected by multiplying composite FT and repeat donor incidence rates by HIV marker-negative infectious window periods. RESULTS: HIV prevalence among FT donors was 92.2/ 105 donations. FT and repeat donor and composite incidences were 38.5 (95% confidence interval [CI], 25.651.4), 22.5 (95% CI, 17.6-28.0), and 27.5 (95% CI, 22.0-33.0) per 100,000 person-years, respectively. Male and community donors had higher prevalence and incidence rates than female and replacement donors. The estimated residual risk of HIV transfusion transmission was 11.3 per 106 donations (95% CI, 8.4-14.2), which could be reduced to 4.2 per 106 donations (95% CI, 3.2-5.2) by use of individual-donation nucleic acid testing (NAT). CONCLUSION: The incidence and residual transfusion risk of HIV infection are relatively high in Brazil. Implementation of NAT will not be sufficient to decrease transmission rates to levels seen in the United States or Europe; therefore, other measures focused on decreasing donations by at-risk individuals are also necessary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Brazilian blood centers ask candidate blood donors about the number of sexual partners in the past 12 months. Candidates who report a number over the limit are deferred. We studied the implications of this practice on blood safety. STUDY DESIGN AND METHODS: We analyzed demographic characteristics, number of heterosexual partners, and disease marker rates among 689,868 donations from three Brazilian centers between July 2007 and December 2009. Donors were grouped based on maximum number of partners allowed in the past 12 months for each center. Chi-square and logistic regression analysis were conducted to examine associations between demographic characteristics, number of sex partners, and individual and overall positive markers rates for human immunodeficiency virus (HIV), human T-lymphotropic virus Types 1 and 2, hepatitis B virus, hepatitis C virus, and syphilis. RESULTS: First-time, younger, and more educated donors were associated with a higher number of recent sexual partners, as was male sex in Sao Paulo and Recife (p < 0.001). Serologic markers for HIV and syphilis and overall were associated with multiple partners in Sao Paulo and Recife (p < 0.001), but not in Belo Horizonte (p = 0.05, p = 0.94, and p = 0.75, respectively). In logistic regression analysis, number of recent sexual partners was associated with positive serologic markers (adjusted odds ratio [AOR], 1.2-1.5), especially HIV (AOR, 1.9-4.4). CONCLUSIONS: Number of recent heterosexual partners was associated with HIV positivity and overall rates of serologic markers of sexually transmitted infections. The association was not consistent across centers, making it difficult to define the best cutoff value. These findings suggest the use of recent heterosexual contacts as a potentially important deferral criterion to improve blood safety in Brazil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Evaluation of the antimicrobial effect of skin disinfection techniques is essential to avoid the transmission of infectious agents during blood transfusion. The aim of this study was to examine the effectiveness of two methods of arm skin disinfection used in blood donors at a Hemotherapy Center in Brazil that represents an important centre for distributing haemocomponents to many cities in the country. Methods: Two skin disinfection techniques in 50 blood donors were evaluated. For the first arm, 10% povidone-iodine/two-stage technique was used. On the opposite arm, 0.5% chlorhexidine digluconate alcohol solution/one-stage technique was used. The swabs were seeded on three culture media: blood agar, mannitol salt agar and Mac Conkey agar. Automated bacterial classification based on biochemical tests/specific substrates was performed. Donor characteristics were collected using the computerised system of the Hemotherapy Center. Results: We found that microbial reduction was significantly higher for 10% povidone-iodine technique (98.57-98.87%) when compared with 0.5% chlorhexidine technique (94.38-95.06%). The species Leuconostoc mesenteroides and Staphylococcus hominis showed resistance to both disinfection techniques. We did not find statistically significant relationships between donor characteristics and microbial reduction. Conclusions: Arm skin disinfection with 10% povidone-iodine produced better antimicrobial activity. We must acknowledge that 10% povidone-iodine technique has the limitation of being a two-stage method. However, prevention of adverse events due to bacterial contamination and transfusion reactions should be prioritised. Production of hypoallergenic and stronger antiseptics that allowed a safe one-stage disinfection technique should be encouraged in health systems, not only in Brazil but also around the world.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The direct killing of target cells by cytotoxic T lymphocytes (CTLs) plays a fundamental role in protective immunity to viral, bacterial, protozoan and fungi infections, as well as to tumor cells. In vivo cytotoxic assays take into account the interaction of target and effector cells in the context of the proper microenvironment making the analysis biologically more relevant than in vitro cytotoxic assays. Thus, the development, improvement and validation of in vivo methods are necessary in view of the importance of the results they may provide. We describe and discuss in this manuscript a method to evaluate in vivo specific cytotoxic T lymphocyte killing. We used as model system mice immunized with human recombinant replication-deficient adenovirus 5 (HAd5) containing different transgenes as the trigger of a CTL-mediated immune response. To these mice, we adoptively transferred syngeneic cells labeled with different vital fluorescent dyes. Donor cells were pulsed (target) or not (control non-target) with distinct CD8 T-cell epitopes, mixed in a 1:1 ratio and injected i.v. into immunized or non-immunized recipient mice. After 18-24h, spleen cells are collected and analysed by flow cytometry. A deviation from the 1:1 ratio of control and target cell populations indicates antigen specific lysis of target cells