29 resultados para denture rebasing

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the expression of pattern recognition receptors (PRRs) and activation factors associated with salivary and blood neutrophils from different aged patients diagnosed with Candida-related denture stomatitis (DS). Expression of neutrophil PRRs was determined by flow cytometry and immunofluorescence, and the levels of selected cytokines that influence immune activation were determined by ELISA. The salivary (but not the serum derived) neutrophils of individuals with DS were found to have an increased expression of CD69 regardless of the age of the patient compared to patients without DS. However, these salivary neutrophils had a lower expression of CD66b and CD64. Expression of TLR2 was lower on the salivary-and serum-derived neutrophils from elderly individuals compared to the neutrophils of younger subjects, regardless of whether the individual had DS. Salivary interleukin (IL)-4 was elevated in both of the elderly subject groups (with or without DS). Only elderly DS patients were observed to have increased serum IL-4 levels and reduced salivary IL-12 levels. Younger DS patients showed an increase in salivary IL-10 levels, and both the saliva and the serum levels of IFN-gamma were increased in all of the younger subjects. Our data demonstrated that changes in both the oral immune cells and the protein components could be associated with DS. Furthermore, changes in the blood-derived factors were more associated with age than DS status. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study aimed to investigate (1) the influence of complete denture quality and years of denture use on masticatory efficiency and (2) the relationship between complete denture quality and years of use. Materials and Methods: A cross-sectional study was conducted with 93 edentulous patients (mean age: 65.6 years) wearing both mandibular and maxillary dentures. Patients were classified into two categories according to years of denture use: <= 2 years and >= 5 years. Masticatory efficiency was evaluated via the colorimetric method with beads as the artificial test food. A reproducible method for objective evaluation of the technical quality of complete dentures was employed. The association between denture quality and years of denture use was analyzed using chi-square and Fisher exact tests. The results of masticatory efficiency testing were analyzed using two-way analysis of variance (with the Tukey post hoc test) in terms of years of denture use <= 2 years, >= 5 years) and denture quality (poor, average, good). Results: A significant relationship was found between denture quality and years of denture use (P < .05). Masticatory efficiency differed significantly (P < .05) between patients with <= 2 years of denture use (0.101 +/- 0.076 absorbance) and >= 5 years of use (0.068 +/- 0.076 absorbance). Masticatory efficiency was not influenced by denture quality. Conclusions: Complete denture quality and masticatory efficiency significantly decreased over time. However, complete denture quality did not influence masticatory efficiency. Int J Prosthodont 2012;25:625-630.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is no consensus in the literature about the impact of complete denture wear on obstructive sleep apnea (OSA). The goal of this randomized clinical study was to assess if complete denture wear during sleep interferes with the quality of sleep. Elderly edentulous OSA patients from a complete denture clinic were enrolled and received new complete dentures. An objective sleep analysis was determined with polysomnography performed at the sleep laboratory for all patients who slept either with or without their dentures. Twenty-three patients (74% females) completed the study with a mean age of 69.6 years and a mean body mass index of 26.7 kg/m(2). The apnea and hypopnea index (AHI) was significantly higher when patients slept with dentures compared to without (25.9 +/- 14.8/h vs. 19.9 +/- 10.2/h; p > 0.005). In the mild OSA group, the AHI was significantly higher when patients slept with the dentures (16.6 +/- 6.9 vs. 8.9 +/- 2.4; p < 0.05), while in moderate to severe OSA patients, the AHI was not significantly different when sleeping with dentures (.30.8 +/- 15.6 vs. 25.7 +/- 7.5; p = 0.2). The supine AHI in mild patients was related to a higher increase in AHI while wearing dentures (12.7 +/- 8.4/h vs. 51.9 +/- 28.6/h; p < 0.001). A limitation of the study is that the mild OSA patients had a higher BMI when compared to the moderate to severe OSA patients. Ten out of 14 patients who preferred to sleep with their upper and lower dentures showed an increase in their AHI while wearing dentures to sleep. Contrary to previous studies, we found that OSA patients may experience more apneic events if they sleep with their dentures in place. Specifically, in mild OSAS patients, the use of dentures substantially increases the AHI especially when in the supine position.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Knowledge of benefits caused by a treatment on quality of life is very relevant. Despite the wide use and acceptance of soft denture liners, it is necessary to evaluate the patient's response about the use of these materials with regard to improvement in oral health related quality of life (OHRQoL). Objectives: The aim of this study was to evaluate the influence of denture relining in the OHRQoL of edentulous patients. Materials and methods: Thirty-two complete denture wearers had their lower dentures relined with a silicone-based material (Mucopren soft, Kettenbach, Germany) according to chairside procedures. OHRQoL was assessed before and after 3 months of relining by means of OHIP-EDENT, and the median scores were compared by Wilcoxon test (p <= 0.05). Results: After 3 months of relining, participants reported significant improvement of their OHRQoL (p <= 0.01). Conclusion: Denture relining with a soft liner may have a positive impact on the perceived oral health of edentulous patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the Vickers hardness of different acrylic resins for denture bases with and without the addition of glass fibres. Background: It has been suggested that different polymerisation methods, as well as the addition of glass fibre (FV) might improve the hardness of acrylic. Materials and methods: Five types of acrylic resin were tested: Vipi Wave (VW), microwave polymerisation; Vipi Flash (VF), auto-polymerisation; Lucitone (LT), QC20 (QC) and Vipi Cril (VC), conventional heat-polymerisation, all with or without glass fibre reinforcement (GFR) and distributed into 10 groups (n = 12). Specimens were then submitted to Vickers hardness testing with a 25-g load for 30 s. All data were submitted to ANOVA and Tukey's HSD test. Results: A significant statistical difference was observed with regard to the polymerisation method and the GFR (p < 0.05). Without the GFR, the acrylic resin VC presented the highest hardness values, and VF and LT presented the lowest. In the presence of GFR, VC resin still presented the highest Vickers hardness values, and VF and QC presented the lowest. Conclusions: The acrylic resin VC and VW presented higher hardness values than VF and QC resins. Moreover, GFR increased the Vickers hardness of resins VW, VC and LT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Elderly individuals with Candida-related denture stomatitis (DS) present with a reduced defence against Candida albicans. This study evaluated levels of antimicrobial mediators in the elderly DS saliva and salivary neutrophils' activation characteristics compared with elderly and young without DS. Methods: Salivary peroxidases (SPO) and elastase activities (ELA), nitric oxide (NO), transforming growth factor beta (TGF-beta), IL-6 and CCL3 production were determined in saliva from elderly with or without DS, and young control individuals. TLR4, CXCR1, CD11b, CD16 and CD32 expression on salivary neutrophils were evaluated. Correlations between number and apoptosis rate of salivary neutrophils, enzymatic activities and cytokine levels were determined. Results: Elderly DS individuals exhibited the lowest SPO and ELA activities. Also, the activity of both enzymes was low in elderly without DS. Although both elderly groups showed higher salivary NO and TGF-beta levels compared to young control groups, elderly DS presented the highest salivary NO, TGF-beta, IL-6 and CCL3 levels. Decreased percentages of salivary TLR4(+) and CD16(+) neutrophils were detected in both elderly groups. Although these damages could influence the establishment and persistence of DS, the highest levels of salivary IL-6 and CCL3 in elderly DS could be preventing more serious complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study evaluated colour stability, hardness and roughness of soft denture liners after immersion in various cleansers. Materials and methods: Thirty specimens (14 mm x 4 mm) of Elite Soft Relining (ES) and Mucopren Soft (MS) were randomly immersed in distilled water at 37 degrees C, sodium hypochlorite 1%, and an experimental Ricinus communis solution (RC) for 7, 15 and 183 continuous days. Results: ANOVA (p < 0.05) and Tukey's test indicated that after T7 (mu =8.79 +/- 7.36); T15 (mu = 4.23 +/- 2.62) and T183 (mu = 8.78 +/- 3.16), MS presented a higher increase in hardness than ES. After T7, MS underwent an increase in roughness (mu = 0.09 +/- 0.80); ES underwent a decrease (mu = -0.08 +/- 0.16). RC caused the smallest variation in roughness. After T15, both materials presented an increase in roughness. After T183, ES (mu = -0.30 +/- 0.48) presented a higher roughness variation than MS (mu = -0.07 +/- 0.32). Hypochlorite caused an increase in roughness (mu = 0.02 +/- 0.19). Conclusion: After all periods ES presented higher colour alteration than MS; highest colour alteration was caused by hypochlorite. Both materials were more stable after immersion in RC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to prolong the clinical longevity of resilient denture relining materials and reduce plaque accumulation, incorporation of antimicrobial agents into these materials has been proposed. However, this addition may affect their properties. Objective: This study evaluated the effect of the addition of antimicrobial agents into one soft liner (Soft Confort, Dencril) on its peel bond strength to one denture base (QC 20, Dentsply). Material and Methods: Acrylic specimens (n=9) were made (75x10x3 mm) and stored in distilled water at 37 degrees C for 48 h. The drug powder concentrations (nystatin 500,000U - G2; nystatin 1,000,000U - G3; miconazole 125 mg - G4; miconazole 250 mg - G5; ketoconazole 100 mg - G6; ketoconazole 200 mg - G7; chlorhexidine diacetate 5% - G8; and 10% chlorhexidine diacetate - G9) were blended with the soft liner powder before the addition of the soft liner liquid. A group (G1) without any drug incorporation was used as control. Specimens (n=9) (75x10x6 mm) were plasticized according to the manufacturers' instructions and stored in distilled water at 37 degrees C for 24 h. Relined specimens were then submitted to a 180-degree peel test at a crosshead speed of 10 mm/min. Data (MPa) were analyzed by analysis of variance (alpha=0.05) and the failure modes were visually classified. Results: No significant difference was found among experimental groups (p=0.148). Cohesive failure located within the resilient material was predominantly observed in all tested groups. Conclusions: Peel bond strength between the denture base and the modified soft liner was not affected by the addition of antimicrobial agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have identified impaired neutrophils in elderly individuals which could be involved with -related denture stomatitis (DS), an oral infection predominantly caused by , affecting especially elderly individuals using dental prosthesis. However, specific mechanisms performed by neutrophil contributing to the susceptibility of the elderly to DS are not fully understood. This study evaluated activation features of blood neutrophils from elderly and young individuals with DS. Blood neutrophils cultured with . from elderly subjects secreted decreased levels of CXCL8. However, . challenged-neutrophils from DS patients produced high IL-4 and IL-10, and low GM-CSF levels, regardless of age. Additional elastase activity of neutrophils from both elderly groups was detected after incubation with . , but only neutrophils from elderly DS demonstrated high myeloperoxidase activity. Therefore, DS patients have affected neutrophils, and the advance of age intensifies these damages. In sumamry, individuals with -related denture stomatitis presented variation in the neutrophil phenotype and activation. Such alterations were more intense in neutrophils from infected elderly individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Adequate denture hygiene can prevent and treat infection in edentulous patients, who are frequently elderly and have difficulty brushing their teeth. This study evaluated the efficacy of complete denture biofilm removal using a chlorhexidine solution in two concentrations: 0.12% and 2.0%. Materials and Methods: Sixty complete denture wearers participated in a trial for 21 days after receiving brushing instructions. They were distributed into three groups, according to the tested solution and regimen (n = 20): (G1) Control (daily overnight soaking in water); (G2) daily immersion at home in 0.12% chlorhexidine for 20 minutes after dinner; and (G3) a single immersion in 2.0% chlorhexidine for 5 minutes at the end of the experimental period, performed by a professional. Biofilm coverage area (%) was quantified on the internal surface of maxillary dentures at baseline and after 21 days. Afterward, the differences between initial and posttreatment results were compared by means of the Kruskal-Wallis test (a = 0.05). Results: Median values for biofilm coverage area after treatment were: (G1) 36.0%; (G2) 5.3%; and (G3) 1.4%. Differences were significant (KW = 35.25; p < 0.001), although G2 and G3 presented similar efficacy in terms of biofilm removal. Conclusions: Both chlorhexidine-based treatments had a similar ability to remove denture biofilm. Immersion in 0.12% or 2.0% chlorhexidine solutions can be used as an auxiliary method for cleaning complete dentures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clin Microbiol Infect 2012; 18: E380E388 Abstract In this randomized clinical trial, the clinical and mycological efficacy of Photodynamic Therapy (PDT) was compared with that of topical antifungal therapy for the treatment of denture stomatitis (DS) and the prevalence of Candida species was identified. Patients were randomly assigned to one of two groups (n = 20 each); in the nystatin (NYT) group patients received topical treatment with nystatin (100 000 IU) four times daily for 15 days and in the PDT group the denture and palate of patients were sprayed with 500 mg/L of Photogem (R), and after 30 min of incubation, were illuminated by light emitting-diode light at 455 nm (37.5 and 122 J/cm2, respectively) three times a week for 15 days. Mycological cultures taken from dentures and palates and standard photographs of the palates were taken at baseline (day 0), at the end of the treatment (day 15) and at the follow-up time intervals (days 30, 60 and 90). Colonies were quantified (CFU/mL) and identified by biochemical tests. Data were analysed by Fishers exact test, analysis of variance and Tukey tests and ? test (a = 0.05). Both treatments significantly reduced the CFU/mL at the end of the treatments and on day 30 of the follow-up period (p <0.05). The NYT and PDT groups showed clinical success rates of 53% and 45%, respectively. Candida albicans was the most prevalent species identified. PDT was as effective as topical nystatin in the treatment of DS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background Ageing leads to a decline in the function of the immune system, increasing the body's susceptibility to infections through the impairment of T-cells, macrophages, neutrophils and dendritic cells Denture stomatitis is a primary oral disease affecting elderly denture wearers. The major etiologic factor involved in this pathology is the infection by Candida albicans, an opportunistic pathogen that causes local and disseminated diseases in immunosuppressed humans. Neutrophils play a critical role in the immune response against C. albicans and are continually present in the salivary fluid and in the blood. The aim of this study was to determine ageing-related changes in salivary and blood neutrophils and their potential implications in Candida-related denture stomatitis. Results Our results showed a lower number of neutrophils in the saliva from patients presenting Candida-related denture stomatitis in comparison to their matched controls. Furthermore, fewer neutrophils were isolated from the saliva of aged control individuals in comparison to matched younger subjects. CXCR1, CD62L and CD11b expression were significantly greater on systemic neutrophils from younger control individuals. Elderly individuals showed more apoptotic salivary neutrophils and lower GM-CSF levels than younger ones, regardless of the occurrence of Candida infection. On the other hand, CXCL-8 concentrations were higher in the saliva from elderly individuals. Besides, TNF-α was detected at elevated levels in the saliva from infected elderly subjects. Salivary neutrophils from elderly and young patients presented impaired phagocytic activity against C. albicans. However, just systemic neutrophils from elderly showed decreased phagocytosis when compared to the younger ones, regardless of the occurrence of infection. In addition, neutrophils from aged individuals and young patients presented low fungicidal activity. Conclusion The data suggests that the Candida related-denture stomatitis is associated to neutrophils function deficiency, and ageing drastically appears to alter important characteristics of such cells, facilitating the establishment of this infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the aesthetics of an implant-supported denture at the cleft area, comparing the peri-implant tissues and prosthetic crown with the contralateral tooth. Settings: Hospital for Rehabilitation of Craniofacial Anomalies, Bauru, São Paolo, Brazil. Patients: A total of 39 individuals of both genders, with complete unilateral cleft lip and palate, who received secondary alveolar bone graft and were rehabilitated with single implant-supported dentures at the area of the missing maxillary lateral incisor after completion of orthodontic treatment. Interventions: The following parameters were analyzed in follow-up sessions: length and width of prosthetic crown and contralateral tooth, characteristics of implants, filling of interproximal space by the papilla, and smile height of the patients. Results: The implant-supported prosthetic crowns were longer than the contralateral tooth (p < .001). Among the 78 papillae analyzed, 29 (37.17%) received a score of 3; 32 (41.02%) papillae had a score of 2; and 17 (21.79%) received a score of 1. Concerning the smile height, among the 39 patients analyzed, 23 (56.41%) had a medium smile, 15 (38.46%) had a high smile, and two (5.12%) presented a low smile. Conclusion: The use of dental implants to rehabilitate the edentulous cleft area is an excellent option. However, adequate evaluation of the bone quantity and quality, positioning and shape of adjacent teeth, smile height, and patient expectations should be considered to achieve success and avoid aesthetic deformities such as elongated teeth and absence of gingival papillae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated Knoop hardness, surface roughness and color alteration of artificial teeth for dentures after immersion in water, 1% sodium hypochlorite and an experimental solution of 2% Ricinus communis (RC). Thirty specimens of Vipi, Biolux and Trilux were analyzed. Tests of Knoop hardness, surface roughness and color alteration were conducted immediately after specimen preparation (T0) and after two immersion protocols for 15 days (ΔT15) and 183 days (ΔT183). Data variation (ΔT) were subjected to ANOVA and Tukey's test (p<0.05). At ΔT15, Vipi presented hardness increase and Biolux presented the highest variation (p=0.01). RC caused the highest increase in hardness (p=0) and the lowest increase (p=0.005) in roughness. Biolux presented the lowest color alteration (p =0). At ΔT183, Trilux underwent the highest hardness variation (p=0). Biolux presented an increase in roughness (p=0). There was no significant differences in color alteration among the artificial teeth (p=0.06) and among solutions (p=0.08) after 183 days of immersion. All solutions (distilled water, 1% sodium hypochlorite and 2% RC) caused alterations on the analyzed properties. Both immersion protocols caused alterations on the analyzed properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study analyzed the weight loss and surface roughness caused in Plexiglass specimens by conventional dentifrices (Sorriso, Colgate and Close Up) and specific dentifrices used for cleaning of dentures (Corega and Dentu Creme). Plexiglass specimens were divided into 6 groups (n=6) including: a control (distilled water - DW) and experimental groups. Brushing was performed in a toothbrushing machine with a soft brush and a dentifrice suspension and DW according to different brushing times (50, 100, 200 and 250 min -18,000, 36,000, 72,000 and 90,000 cycles, respectively, calculated to correspond to 1, 2, 4 and 5 years of regular brushing). The results of weight loss and surface roughness were analyzed by ANOVA and Tukey’s test at 5% significance level. In all tested times, the effect of DW was insignificant. Dentifrices differed significantly from DW in the initial period. Corega dentifrice caused greater mass loss in all studied times, followed by Close Up. Dentifrices resulted in a surface roughness similar to the DW at 50 min. In the other times, Sorriso, Colgate and Corega caused more surface roughness than DW. In conclusion, specific dentifrices caused larger mass loss and lower surface roughness as conventional dentifrice.