22 resultados para condition monitoring method
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
We present a simultaneous optical signal-to-noise ratio (OSNR) and differential group delay (DGD) monitoring method based on degree of polarization (DOP) measurements in optical communications systems. For the first time in the literature (to our best knowledge), the proposed scheme is demonstrated to be able to independently and simultaneously extract OSNR and DGD values from the DOP measurements. This is possible because the OSNR is related to maximum DOP, while DGD is related to the ratio between the maximum and minimum values of DOP. We experimentally measured OSNR and DGD in the ranges from 10 to 30 dB and 0 to 90 ps for a 10 Gb/s non-return-to-zero signal. A theoretical analysis of DOP accuracy needed to measure low values of DGD and high OSNRs is carried out, showing that current polarimeter technology is capable of yielding an OSNR measurement within 1 dB accuracy, for OSNR values up to 34 dB, while DGD error is limited to 1.5% for DGD values above 10 ps. For the first time to our knowledge, the technique was demonstrated to accurately measure first-order polarization mode dispersion (PMD) in the presence of a high value of second-order PMD (as high as 2071 ps(2)). (C) 2012 Optical Society of America
Resumo:
Purpose: Fungi are a major cause of keratitis, although few medications are licensed for their treatment. The aim of this study is to observe the variation in commercialisation of antifungal eye drops, and to predict the seasonal distribution of fungal keratitis in Brazil. Methods: Data from a retrospective study of antifungal eye drops sales from the only pharmaceutical ophthalmologic laboratory, authorized to dispense them in Brazil (Opthalmos) were gathered. These data were correlated with geographic and seasonal distribution of fungal keratitis in Brazil between July 2002 and June 2008. Results: A total of 26,087 antifungal eye drop units were sold, with a mean of 2.3 per patient. There was significant variation in antifungal sales during the year (p < 0.01). A linear regression model displayed a significant association between reduced relative humidity and antifungal drug sales (R-2 = 0.17, p < 0.01). Conclusions: Antifungal eye drops sales suggest that there is a seasonal distribution of fungal keratitis. A possible interpretation is that the third quarter of the year (a period when the climate is drier), when agricultural activity is more intense in Brazil, suggests a correlation with a higher incidence of fungal keratitis. A similar model could be applied to other diseases, that are managed with unique, or few, and monitorable medications to predict epidemiological aspects.
Resumo:
Contamination by butyltin compounds (BTs) has been reported in estuarine environments worldwide, with serious impacts on the biota of these areas. Considering that BTs can be degraded by varying environmental conditions such as incident light and salinity, the short-term variations in such factors may lead to inaccurate estimates of BTs concentrations in nature. Therefore, the present study aimed to evaluate the possibility that measurements of BTs in estuarine sediments are influenced by different sampling conditions, including period of the day (day or night), tidal zone (intertidal or subtidal), and tides (high or low). The study area is located on the Brazilian southeastern coast, Sao Vicente Estuary, at Pescadores Beach, where BT contamination was previously detected. Three replicate samples of surface sediment were collected randomly in each combination of period of the day, tidal zone, and tide condition, from three subareas along the beach, totaling 72 samples. BTs were analyzed by GC-PFPD using a tin filter and a VF-5 column, by means of a validated method. The concentrations of tributyltin (TBT), dibutyltin (DBT), and monobutyltin (MBT) ranged from undetectable to 161 ng Sn g(-1) (d.w.). In most samples (71%), only MBT was quantifiable, whereas TBTs were measured in only 14, suggesting either an old contamination or rapid degradation processes. DBT was found in 27 samples, but could be quantified in only one. MBT concentrations did not differ significantly with time of day, zones, or tide conditions. DBT and TBT could not be compared under all these environmental conditions, because only a few samples were above the quantification limit. Pooled samples of TBT did not reveal any difference between day and night. These results indicated that, in assessing contamination by butyltin compounds, surface-sediment samples can be collected in any environmental conditions. However, the wide variation of BTs concentrations in the study area, i.e., over a very small geographic scale, illustrates the need for representative hierarchical and composite sampling designs that are compatible with the multiscalar temporal and spatial variability common to most marine systems. The use of such sampling designs will be necessary for future attempts to quantitatively evaluate and monitor the occurrence and impact of these compounds in nature
Resumo:
Background Obstructive sleep apnea (OSA) is common among patients with coronary artery disease. However, OSA remains largely under recognized. The lack of clinical suspicion and difficulties to access full polysomnography (PSG) are limiting factors. The aim of this study was to evaluate, among patients referred to coronary artery bypass grafting (CABG): (i) the prevalence of OSA, (ii) the association of OSA with clinical symptoms, (iii) the performance of overnight unattended portable monitoring (PM) as an alternative method for the diagnosis of OSA. Methods Consecutive patients referred for CABG were evaluated by standard physical evaluation and validated questionnaires (Berlin questionnaire and Epworth Sleepiness Scale) and underwent full PSG and PM (Stardust II). Results We studied 70 consecutive patients (76% men), age 58 +/- 7 years (mean +/- SD), BMI [median (interquartile range)] 27.6 kg/m(2) (25.8-31.1). The prevalence of OSA (full PSG) using an apnea-hypopnea index of at least 5 events/h was 87%. Commonly used clinical traits for the screening of OSA such as the Epworth Sleepiness Scale and neck circumference had low sensitivities to detect OSA. In contrast, the Berlin questionnaire showed a good sensitivity (72%) to detect OSA. PM showed good sensitivity (92%) and specificity (67%) for the diagnosis of OSA. Conclusion OSA is strikingly common among patients referred for CABG. The Berlin questionnaire, but not symptom of excessive daytime sleepiness is a useful tool to screen OSA. PM is useful for the diagnosis of OSA and therefore is an attractive tool for widespread use among patients with coronary artery disease. Coron Artery Dis 23:31-38 (C) 2011 Wolters Kluwer Health | Lippincott Williams & Wilkins.
Resumo:
Moreira, A, McGuigan, MR, Arruda, AFS, Freitas, CG, and Aoki, MS. Monitoring internal load parameters during simulated and official basketball matches. J Strength Cond Res 26(3): 861-866, 2012-The purpose of this study was to compare the internal load responses (session rating of perceived exertion [RPE] and salivary cortisol) between simulated and official matches (SM and OM). Ten professional basketball players participated in 2 OMs and 2 SMs during the competition season. Subjects provided saliva samples 30 minutes before the prematch warm-up (PRE) and 10 minutes after the end of the match. Session RPE (CR-10 scale) was assessed 30 minutes after each match. The results from the 2-way analysis of variance showed significant differences for post-OM salivary cortisol as compared with pre-OM values (p < 0.05). No changes were observed for cortisol during the SM. Before the OM, a significant difference in salivary cortisol was observed as compared with pre-SM values (p < 0.05). Moreover, the OM session RPE was significantly greater than that of SM. There was a significant correlation between session RPE and cortisol changes (r = 0.75). In summary, the results of this study showed a greater magnitude of cortisol and session RPE responses after OM as compared with that after SM confirming the hypothesis that a real competition generates a greater stress response than a simulated condition does. The anticipatory effect was also observed in the OM. In addition, the results indicate that session RPE seems to be a viable tool in monitoring internal loads, and the results are useful in providing a better understanding of internal loads imposed by basketball training and competitions. The precise monitoring of these responses might help the coaches to plan appropriate loads maximizing recovery and performance.
Resumo:
Clinicians frequently have to decide when dialysis should be initiated and which modality should be used to support kidney function in critically ill patients with acute kidney injury. In most instances, these decisions are made based on the consideration of a variety of factors including patient condition, available resources and prevailing local practice experience. There is a wide variation worldwide in how these factors influence the timing of initiation and the utilization of various modalities. In this article, we review the therapeutic goals of renal support and the relative advantages and shortcomings of different dialysis techniques. We describe strategies for matching the timing of initiation to the choice of modality to individualize renal support in intensive care unit patients. Copyright (C) 2012 S. Karger AG, Basel
Resumo:
The aim of this work was to perform a systematic study of the parameters that can influence the composition, morphology, and catalytic activity of PtSn/C nanoparticles and compare two different methods of nanocatalyst preparation, namely microwave-assisted heating (MW) and thermal decomposition of polymeric precursors (DPP). An investigation of the effects of the reducing and stabilizing agents on the catalytic activity and morphology of Pt75Sn25/C catalysts prepared by microwave-assisted heating was undertaken for optimization purposes. The effect of short-chain alcohols such as ethanol, ethylene glycol, and propylene glycol as reducing agents was evaluated, and the use of sodium acetate and citric acid as stabilizing agents for the MW procedure was examined. Catalysts obtained from propylene glycol displayed higher catalytic activity compared with catalysts prepared in ethylene glycol. Introduction of sodium acetate enhanced the catalytic activity, but this beneficial effect was observed until a critical acetate concentration was reached. Optimization of the MW synthesis allowed for the preparation of highly dispersed catalysts with average sizes lying between 2.0 and 5.0 nm. Comparison of the best catalyst prepared by MW with a catalyst of similar composition prepared by the polymeric precursors method showed that the catalytic activity of the material can be improved when a proper condition for catalyst preparation is achieved. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
This work develops a computational approach for boundary and initial-value problems by using operational matrices, in order to run an evolutive process in a Hilbert space. Besides, upper bounds for errors in the solutions and in their derivatives can be estimated providing accuracy measures.
Resumo:
Background Recurrent nerve injury is 1 of the most important complications of thyroidectomy. During the last decade, nerve monitoring has gained increasing acceptance in several centers as a method to predict and to document nerve function at the end of the operation. We evaluated the efficacy of a nerve monitoring system in a series of patients who underwent thyroidectomy and critically analyzed the negative predictive value (NPV) and positive predictive value (PPV) of the method. Methods. NIM System efficacy was prospectively analyzed in 447 patients who underwent thyroidectomy between 2001 and 2008 (366 female/81 male; 420 white/47 nonwhite; 11 to 82 years of age; median, 43 years old). There were 421 total thyroidectomies and 26 partial thyroidectomies, leading to 868 nerves at risk. The gold standard to evaluate inferior laryngeal nerve function was early postoperative videolaryngoscopy, which was repeated after 4 to 6 months in all patients with abnormal endoscopic findings. Results. At the early evaluation, 858 nerves (98.8%) presented normal videolaryngoscopic features after surgery. Ten paretic/paralyzed nerves (1.2%) were detected (2 unexpected unilateral paresis, 2 unexpected bilateral paresis, 1 unexpected unilateral paralysis, 1 unexpected bilateral paralyses, and 1 expected unilateral paralysis). At the late videolaryngoscopy, only 2 permanent nerve paralyses were noted (0.2%), with an ultimate result of 99.8% functioning nerves. Nerve monitoring showed absent or markedly reduced electrical activity at the end of the operations in 25/868 nerves (2.9%), including all 10 endoscopically compromised nerves, with 15 false-positive results. There were no false-negative results. Therefore, the PPV was 40.0%, and the NPV was 100%. Conclusions. In the present series, nerve monitoring had a very high PPV but a low NPV for the detection of recurrent nerve injury. (C) 2011 Wiley Periodicals, Inc. Head Neck 34: 175-179, 2012
Resumo:
The leaf area index (LAI) is a key characteristic of forest ecosystems. Estimations of LAI from satellite images generally rely on spectral vegetation indices (SVIs) or radiative transfer model (RTM) inversions. We have developed a new and precise method suitable for practical application, consisting of building a species-specific SVI that is best-suited to both sensor and vegetation characteristics. Such an SVI requires calibration on a large number of representative vegetation conditions. We developed a two-step approach: (1) estimation of LAI on a subset of satellite data through RTM inversion; and (2) the calibration of a vegetation index on these estimated LAI. We applied this methodology to Eucalyptus plantations which have highly variable LAI in time and space. Previous results showed that an RTM inversion of Moderate Resolution Imaging Spectroradiometer (MODIS) near-infrared and red reflectance allowed good retrieval performance (R-2 = 0.80, RMSE = 0.41), but was computationally difficult. Here, the RTM results were used to calibrate a dedicated vegetation index (called "EucVI") which gave similar LAI retrieval results but in a simpler way. The R-2 of the regression between measured and EucVI-simulated LAI values on a validation dataset was 0.68, and the RMSE was 0.49. The additional use of stand age and day of year in the SVI equation slightly increased the performance of the index (R-2 = 0.77 and RMSE = 0.41). This simple index opens the way to an easily applicable retrieval of Eucalyptus LAI from MODIS data, which could be used in an operational way.
Resumo:
The aim of this study was to assess, in vivo, the accuracy of the NovApex (R) electronic foramen locator in determining working length (WL) in vital and necrotic posterior teeth. The NovApex (R) was used in 144 canals: 35 teeth with vital pulps (68 canals) and 42 teeth with necrotic pulps (76 canals). WL was measured with the NovApex (R) locator and confirmed using the radiographic method. Differences between electronic and radiographic measurements ranging between 0.0 and 0.4 millimeters were classified as acceptable; differences equal to or greater than 0.5 millimeter were considered unacceptable. Pearson's chi-square test was used to assess the influence of pulp condition on the accuracy of NovApex (R) (alpha = 0.05). Regardless of pulp condition, differences between electronic and radiographic WL measurements were acceptable in 73.61% of the canals. No statistically significant differences in accuracy were observed when comparing vital and necrotic canals (p > 0.05). There were 38 unacceptable measurements. In none of these cases was the file tip located beyond the radiographic apex; in 32, it was located short of the NovApex (R) measurement. Pulp condition had no significant effect on the accuracy of NovApex (R).
Translocation capture sequencing: A method for high throughput mapping of chromosomal rearrangements
Resumo:
Chromosomal translocations require formation and joining of DNA double strand breaks (DSBs). These events disrupt the integrity of the genome and are involved in producing leukemias, lymphomas and sarcomas. Translocations are frequent, clonal and recurrent in mature B cell lymphomas, which bear a particularly high DNA damage burden by virtue of activation-induced cytidine deaminase (AID) expression. Despite the ubiquity of genomic rearrangements, the forces that underlie their genesis are not well understood. Here, we provide a detailed description of a new method for studying these events, translocation capture sequencing (TC-Seq). TC-Seq provides the means to document chromosomal rearrangements genome-wide in primary cells, and to discover recombination hotspots. Demonstrating its effectiveness, we successfully estimate the frequency of c-myc/IgH translocations in primary B cells, and identify hotspots of AID-mediated recombination. Furthermore. TC-Seq can be adapted to generate genome-wide rearrangement maps in any cell type and under any condition. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
At each outer iteration of standard Augmented Lagrangian methods one tries to solve a box-constrained optimization problem with some prescribed tolerance. In the continuous world, using exact arithmetic, this subproblem is always solvable. Therefore, the possibility of finishing the subproblem resolution without satisfying the theoretical stopping conditions is not contemplated in usual convergence theories. However, in practice, one might not be able to solve the subproblem up to the required precision. This may be due to different reasons. One of them is that the presence of an excessively large penalty parameter could impair the performance of the box-constraint optimization solver. In this paper a practical strategy for decreasing the penalty parameter in situations like the one mentioned above is proposed. More generally, the different decisions that may be taken when, in practice, one is not able to solve the Augmented Lagrangian subproblem will be discussed. As a result, an improved Augmented Lagrangian method is presented, which takes into account numerical difficulties in a satisfactory way, preserving suitable convergence theory. Numerical experiments are presented involving all the CUTEr collection test problems.
Resumo:
Background: Specific research tools and designs can assist in identifying the efficiency of physical activity in elderly women. Objectives: To identify the effects of physical activity on the physical condition of older women. Method: A one-year-long physical activity program (123 sessions) was implemented for women aged 60 years or older. Four physical assessments were conducted, in which weight, height, BMI, blood pressure, heart rate, absences, grip strength, flexibility, VO2max, and static and dynamic balance were assessed. The statistical analyses included a repeated measures analysis, both inferential (analysis of variance - ANOVA) and effect size (Cohen's d coefficient), as well as identification of the participants' efficiency (Data Envelopment Analysis - DEA). Results: Despite the observation of differences that depended on the analysis used, the results were successful in the sense that they showed that physical activity adapted to older women can effectively change the decline in physical ability associated with aging, depending on the purpose of the study. The 60-65 yrs group was the most capable of converting physical activity into health benefits in both the short and long term. The >65 yrs group took less advantage of physical activity. Conclusions: Adherence to the program and actual time spent on each type of exercise are the factors that determine which population can benefit from physical activity programs. The DEA allows the assessment of the results related to time spent on physical activity in terms of health concerns. Article registered in Clinicaltrials.gov under number NCT01558401.
Resumo:
The aim of this study is to develop a new enzymeless electroanalytical method for the indirect quantification of creatinine from urine sample. This method is based on the electrochemical monitoring of picrate anion reduction at a glassy carbon electrode in an alkaline medium before and after it has reacted with creatinine (Jaffe's reaction). By using the differential pulse voltammetry technique under the optimum experimental conditions (step potential, amplitude potential, reaction time, and temperature), a linear analytical curve was obtained for concentrations of creatinine ranging from 1 to 80 mu mol L-1, with a detection limit of 380 nmol L-1. This proposed method was used to measure creatinine in human urine without the interference of most common organic species normally present in biological fluids (e.g., uric acid, ascorbic acid, glucose, and phosphocreatinine). The results obtained using urine samples were highly similar to the results obtained using the reference spectrophotometric method (at a 95% confidence level). (C) 2012 Elsevier B.V. All rights reserved.