22 resultados para blur distortion
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Stereoscopic depth perception utilizes the disparity cues between the images that fall on the retinae of the two eyes. The purpose of this study was to determine what role aging and optical blur play in stereoscopic disparity sensitivity for real depth stimuli. Forty-six volunteers were tested ranging in age from 15 to 60 years. Crossed and uncrossed disparity thresholds were measured using white light under conditions of best optical correction. The uncrossed disparity thresholds were also measured with optical blur (from +1.0D to +5.0D added to the best correction). Stereothresholds were measured using the Frisby Stereo Test, which utilizes a four-alternative forced-choice staircase procedure. The threshold disparities measured for young adults were frequently lower than 10 arcsec, a value considerably lower than the clinical estimates commonly obtained using Random Dot Stereograms (20 arcsec) or Titmus Fly Test (40 arcsec) tests. Contrary to previous reports, disparity thresholds increased between the ages of 31 and 45 years. This finding should be taken into account in clinical evaluation of visual function of older patients. Optical blur degrades visual acuity and stereoacuity similarly under white-light conditions, indicating that both functions are affected proportionally by optical defocus.
Resumo:
The study proposes a constrained least square (CLS) pre-distortion scheme for multiple-input single-output (MISO) multiple access ultra-wideband (UWB) systems. In such a scheme, a simple objective function is defined, which can be efficiently solved by a gradient-based algorithm. For the performance evaluation, scenarios CM1 and CM3 of the IEEE 802.15.3a channel model are considered. Results show that the CLS algorithm has a fast convergence and a good trade-off between intersymbol interference (ISI) and multiple access interference (MAI) reduction and signal-to-noise ratio (SNR) preservation, performing better than time-reversal (TR) pre-distortion.
Resumo:
This paper presents a performance analysis of a baseband multiple-input single-output ultra-wideband system over scenarios CM1 and CM3 of the IEEE 802.15.3a channel model, incorporating four different schemes of pre-distortion: time reversal, zero-forcing pre-equaliser, constrained least squares pre-equaliser, and minimum mean square error pre-equaliser. For the third case, a simple solution based on the steepest-descent (gradient) algorithm is adopted and compared with theoretical results. The channel estimations at the transmitter are assumed to be truncated and noisy. Results show that the constrained least squares algorithm has a good trade-off between intersymbol interference reduction and signal-to-noise ratio preservation, providing a performance comparable to the minimum mean square error method but with lower computational complexity. Copyright (C) 2011 John Wiley & Sons, Ltd.
Resumo:
After sintering advanced ceramics, there are invariably distortions, caused in large part by the heterogeneous distribution of density gradients along the compacted piece. To correct distortions, machining is generally used to manufacture pieces within dimensional and geometric tolerances. Hence, narrow material removal limit conditions are applied, which minimize the generation of damage. Another alternative is machining the compacted piece before sintering, called the green ceramic stage, which allows machining without damage to mechanical strength. Since the greatest concentration of density gradients is located in the outer-most layers of the compacted piece, this study investigated the removal of different allowance values by means of green machining. The output variables are distortion after sintering, tool wear, cutting force, and the surface roughness of the green ceramics and the sintered ones. The following results have been noted: less distortion is verified in the sintered piece after 1mm allowance removal; and the higher the tool wear the worse the surface roughness of both green and sintered pieces.
Resumo:
Background: The aim of this study was to investigate the effects of sub-clinical alterations on the amplitudes and slopes of the DPOAE input-output responses from subjects with previous history of middle ear dysfunction. Material/Methods: The study included 15 subjects with and 15 subjects without a history of otitis media in the last 10 years. All participants were assessed with acoustic immittance, pure-tone audiometry, and DPOAEs. For the later, I/O functions and I/O slopes were estimated at 1501, 2002, 3174, 4004 and 6384Hz. Results: No statistically significant differences were found between the 2 groups in terms of behavioral thresholds. The group with a previous history of middle ear dysfunction presented significantly lower mean DPOAE amplitudes at 2002, 3174 and 4004 Hz. In terms of DPOAE slopes, no statistically significant differences were observed at the tested frequencies, except at 3174 Hz. Conclusions: Middle ear pathologies can produce subclinical alterations that are undetectable with traditional pure-tone audiometry. The data from the present study show that reduced amplitude DPOAEs are associated with a previous history of middle ear complications. The corresponding DPOAE slopes were affected at only 1 tested frequency, suggesting that the cochlear non-linearity is preserved. Considering these results, it remains to be elucidated to what degree the DPOAE amplitude attenuation interferes with higher-order auditory tasks.
Resumo:
Nowadays, the zinc oxide surge arresters (ZnO) are widely used in power systems, however, a large number of silicon carbide surge arresters (SiC) are still in service in the utilities. On the other hand, it is not possible to replace all SiC surge arresters in a short time period, being necessary to review the maintenance program taking into account the surge arresters that are more degraded. In this context, a research project was established between the University of Sao Paulo and the electrical utility CTEEP, aiming the investigation of its SiC surge arresters. This work shows that the leakage current measurement, a diagnostic method for the ZnO surge arresters, can provide useful information related to the condition of the SiC surge arresters. Analysis of the amplitude and distortion of the leakage current, also considering thermovision measurements, resulted in better evaluation of the SiC surge arresters.
Resumo:
Color vision was examined in subjects with long-term occupational exposure to mercury (Hg) vapor. The color vision impairment was assessed by employing a quantitative measure of distortion of individual and group perceptual color spaces. Hg subjects (n = 18; 42.1 +/- 6.5 years old; exposure time = 10.4 +/- 5.0 years; time away from the exposure source = 6.8 +/- 4.6 years) and controls (n = 18; 46.1 +/- 8.4 years old) were examined using two arrangement tests, D-15 and D-15d, in the traditional way, and also in a triadic procedure. From each subject`s `odd-one-out` choices, matrices of inter-cap subjective dissimilarities were derived and processed by non-metric multidimensional scaling (MDS). D-15d results differed significantly between the Hg-group and the control group (p < 0.05), with the impairment predominantly along the tritan axis. 2D perceptual color spaces, individual and group, were reconstructed, with the dimensions interpreted as the red-green (RG) and the blue-yellow (BY) systems. When color configurations from the Hg-group were compared to those of the controls, they presented more fluctuations along both chromatic dimensions, indicating a statistically significant difference along the BY axis. In conclusion, the present findings confirm that color vision impairments persist in subjects that have received long-term occupational exposure to Hg-vapor although, at the time of testing, they were presenting mean urinary concentration within the normal range for non-exposed individuals. Considering the advantages of the triadic procedure in clinical evaluation of acquired color vision deficiencies, further studies should attempt to verify and/or improve its efficacy.
Resumo:
Objectives: The aim of this pilot study was to investigate whether patients with social anxiety disorder (SAD) differ from controls in the quality of skill-related behaviors displayed during a speech and in overall behavioral adequacy as perceived by observers and by the patients themselves. Design: A total of 18 SAD patients and 18 controls were screened by a diagnostic interview and took part in a 3-minute speech of their own choosing. For each videotaped speech, observers rated the adequacy of the skill-related behaviors and overall performance adequacy. After the experiment, participants were asked to rate their own overall performance adequacy. Results: The results showed that SAD patients exhibited significantly worse voice intonation and fluency of the speech, however no differences were found in global self-ratings. Moreover, the performance evaluations of the SAD group were consistent with the observers, while the controls evaluated their performance lower than the observers. Conclusions: The results are inconsistent with the cognitive model, because patients with SAD did not underestimate their performance. Compared with spontaneous interactions, the clear rules established for such social situations as speeches may result in less cognitive distortion for SAD patients. (C) 2012 Wiley Periodicals, Inc. J. Clin. Psychol. 68:397-402, 2012.
Resumo:
The present work employs a set of complementary techniques to investigate the influence of outlying Ru(II) groups on the ground- and excited-state photophysical properties of free-base tetrapyridyl porphyrin (H(2)TPyP). Single pulse and, pulse train Z-scan techniques used M association with laser flash photolysis, absorbance and fluorescence spectroscopy, and fluorescence decay measurements, allowed us to conclude that the presence of outlying Ru(II) groups causes significant changes on both electronic structure and vibrational properties of porphyrin. Such modifications take place mainly due to the activation of. nonradiative decay channels responsible for the emission, quenching, as well as by favoring some vibrational modes in the light absorption process, It is also observed that, differently from what happens when the Ru(II) is placed at the center of the macrocycle, the peripheral groups cause an increase of the intersystem crossing processes, probably due to the structural distortion of the ring that implies a worse spin orbit coupling, responsible for the intersystem crossing mechanism.
Resumo:
PURPOSE. Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS. Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed. RESULTS. The results on the tightened side were significantly lower in Group C (6.43 +/- 3.24 mu m) when compared to Groups A (16.50 +/- 7.55 mu m) and B (16.27 +/- 1.71 mu m) (P<.05). On the opposite side, the diagonal section of the one-piece castings for laser welding showed significant improvement in the levels of misfit of the frameworks (Group A, 58.66 +/- 14.30 mu m; Group B, 39.4.8 +/- 12.03 mu m; Group C, 23.13 +/- 8.24 mu m) (P<.05). CONCLUSION. Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks. [J Adv Prosthodont 2012;4:89-92]
Resumo:
Multidisciplinary benthic studies are still hindered by the lack of a unique fixative that satisfactorily preserves morphology and DNA, and that is simultaneously adequate for ecological surveys. The objective of this study is to test the performance of five fixatives: formalin, ethanol, dimethylsulfoxide with EDTA and NaCl salts (DESS), methanol with acetic acid (METHAC), and ethanol with acetic acid (ETHAC), for the preservation of estuarine and exclusively marine nematode assemblages for morphological, molecular, and ecological studies. The presence of the stain rose bengal in each fixative was also evaluated in the yield of PCR reactions. For molecular analyses, one species of each habitat was considered. Results revealed that fixative performance for morphological studies is habitat-and species-dependent. For studies of estuarine sediment nematodes, we recommend the use of pure ethanol, because it caused little morphological distortion (<10% of the assemblage), preserved all the species for ecological studies, and yielded high quality DNA sequences. For studies of exclusively marine environments, METHAC or DESS are the most adequate. The first performed better for morphological and ecological surveys, whereas the second was more appropriate for molecular research. For ecological studies, DESS should be used in comparison with formalin, in order to cross check the results. Finally, staining of samples with rose bengal is not recommended, because it hindered DNA amplification regardless of the fixative used.
Resumo:
Introduction: The most common indication for surgical correction of giant left atrium is associated with mitral valve insufficiency with or without atrial fibrillation. Several techniques for this purpose are already described with varying results. Objective: To present the initial experience with the tangential triangular resection technique (Pomerantzeff). Methods: From 2002 to 2010, four patients underwent mitral valve operation with reduction of left atrial volume by the technique of triangular resection tangential in our service. Three patients were female. The age ranged from 21 to 51 years old. The four patients presented with atrial fibrillation. Ejection fraction of left ventricle preoperatively ranged from 38% to 62%. The left atrial diameter ranged from 78mm to 140mm. After treatment of mitral dysfunction, the left atrium was reduced by resecting triangular tangential posterior wall between the pulmonary veins to avoid anatomic distortion of the mitral valve or pulmonary veins, reducing tension in the suture line. Results: Average hospital stay was 21.5 +/- 6.5 days. The mean cardiopulmonary bypass time was 130 +/- 30 minutes. There was no surgical bleeding or mortality in the postoperative period. All patients had sinus rhythm restored in the output of cardiopulmonary bypass, maintaining this rate postoperatively. The average diameter of the left atrium was reduced by 50.5% +/- 19.5%. The left ventricular ejection fraction improved in all patients. Conclusion: Initial results with this technique have shown effective reduction of the left atrium.
Resumo:
We present a detailed study of the Baryscan technique, a new efficient alternative to the widespread Z-scan technique which has been demonstrated [Opt. Lett. 36:8, 2011] to reach among the highest sensitivity levels. This method is based upon the measurement of optical nonlinearities by means of beam centroid displacements with a position sensitive detector and is able to deal with any kind of lensing effect. This technique is applied here to measure pump-induced electronic refractive index changes (population lens), which can be discriminated from parasitic thermal effects by using a time-resolved Baryscan experiment. This method is validated by evaluating the polarizability variation at the origin of the population lens observed in the reference Cr3+:GSGG laser material.
Resumo:
OBJECTIVE: Enterobacteriaceae bacteria harboring Klebsiella pneumoniae carbapenemase are a serious worldwide threat. The molecular identification of these pathogens is not routine in Brazilian hospitals, and a rapid phenotypic screening test is desirable. This study aims to evaluate the modified Hodge test as a phenotypic screening test for Klebsiella pneumoniae carbapenemase. METHOD: From April 2009 to July 2011, all Enterobacteriaceae bacteria that were not susceptible to ertapenem according to Vitek2 analysis were analyzed with the modified Hodge test. All positive isolates and a random subset of negative isolates were also assayed for the presence of blaKPC. Isolates that were positive in modified Hodge tests were sub-classified as true-positives (E. coli touched the ertapenem disk) or inconclusive (distortion of the inhibition zone of E. coli, but growth did not reach the ertapenem disk). Negative results were defined as samples with no distortion of the inhibition zone around the ertapenem disk. RESULTS: Among the 1521 isolates of Enterobacteriaceae bacteria that were not susceptible to ertapenem, 30% were positive for blaKPC, and 35% were positive according to the modified Hodge test (81% specificity). Under the proposed sub-classification, true positives showed a 98% agreement with the blaKPC results. The negative predictive value of the modified Hodge test for detection was 100%. KPC producers showed high antimicrobial resistance rates, but 90% and 77% of these isolates were susceptible to aminoglycoside and tigecycline, respectively. CONCLUSION: Standardizing the modified Hodge test interpretation may improve the specificity of KPC detection. In this study, negative test results ruled out 100% of the isolates harboring Klebsiella pneumoniae carbapenemase-2. The test may therefore be regarded as a good epidemiological tool.
Resumo:
Há comprovação de que o fenômeno de resistência ocorre quando a dose não lesiva da amicacina protege as células ciliadas contra a ototoxicidade da própria amicacina. OBJETIVO: O objetivo deste trabalho é verificar se o fenômeno de resistência é temporalmente persistente. MÉTODO: Estudo experimental com 14 cobaias albinas (Cavia porcellus) divididas em três grupos. Avaliação da função auditiva por emissões otoacústicas por produto de distorção (EOAPD): na pré-exposição à amicacina, no 15º dia de aplicação da dose não lesiva, no final da aplicação da dose lesiva e antes da decapitação. RESULTADOS: O Grupo A (controle) apresentou função auditiva e padrão histológico normais. No Grupo B (amicacina 20mg/kg/dia intramuscular por 30 dias e dose lesiva (400 mg/kg/dia) por 12 dias) e no Grupo C (mesmo esquema do grupo B, porém mantidos por 60 dias e sacrificados), as OEA-PD confirmaram função auditiva normal no período pré-exposição e manutenção do padrão após dose não lesiva, porém, houve perda importante da função auditiva após término do período de aplicação da dose lesiva. CONCLUSÃO: Não houve manutenção do fenômeno da autodefesa estendida por um período de 30 a 60 dias após a aplicação de doses lesivas de amicacina.