3 resultados para algebraic dressing method

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a new algebraic-graph method for identification of islanding in power system grids is proposed. The proposed method identifies all the possible cases of islanding, due to the loss of a equipment, by means of a factorization of the bus-branch incidence matrix. The main features of this new method include: (i) simple implementation, (ii) high speed, (iii) real-time adaptability, (iv) identification of all islanding cases and (v) identification of the buses that compose each island in case of island formation. The method was successfully tested on large-scale systems such as the reduced south Brazilian system (45 buses/72 branches) and the south-southeast Brazilian system (810 buses/1340 branches). (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: to compare the performance of undergraduate students concerning semi-implanted central venous catheter dressing in a simulator, with the assistance of a tutor or of a self-learning tutorial. Method: Randomized controlled trial. The sample consisted of 35 undergraduate nursing students, who were divided into two groups after attending an open dialogue presentation class and watching a video. One group undertook the procedure practice with a tutor and the other with the assistance of a self-learning tutorial. Results: in relation to cognitive knowledge, the two groups had lower performance in the pre-test than in the post-test. The group that received assistance from a tutor performed better in the practical assessment. Conclusion: the simulation undertaken with the assistance of a tutor showed to be the most effective learning strategy when compared to the simulation using a self-learning tutorial. Advances in nursing simulation technology are of upmost importance and the role of the tutor in the learning process should be highlighted, taking into consideration the role this professional plays in knowledge acquisition and in the development of critical-reflexive thoughts and attitudes. (ClinicalTrials.gov Identifier: NCT 01614314).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Piezoelectric ceramics, such as PZT, can generate subnanometric displacements, bu t in order to generate multi- micrometric displacements, they should be either driven by high electric voltages (hundreds of volts ), or operate at a mechanical resonant frequency (in narrow band), or have large dimensions (tens of centimeters). A piezoelectric flextensional actuator (PFA) is a device with small dimensions that can be driven by reduced voltages and can operate in the nano- and micro scales. Interferometric techniques are very adequate for the characterization of these devices, because there is no mechanical contact in the measurement process, and it has high sensitivity, bandwidth and dynamic range. A low cost open-loop homodyne Michelson interferometer is utilized in this work to experimentally detect the nanovi brations of PFAs, based on the spectral analysis of the interfero metric signal. By employing the well known J 1 ...J 4 phase demodulation method, a new and improved version is proposed, which presents the following characteristics: is direct, self-consistent, is immune to fading, and does not present phase ambiguity problems. The proposed method has resolution that is similar to the modified J 1 ...J 4 method (0.18 rad); however, differently from the former, its dynamic range is 20% larger, does not demand Bessel functions algebraic sign correction algorithms and there are no singularities when the static phase shift between the interferometer arms is equal to an integer multiple of  /2 rad. Electronic noise and random phase drifts due to ambient perturbations are taken into account in the analysis of the method. The PFA nanopositioner characterization was based on the analysis of linearity betw een the applied voltage and the resulting displacement, on the displacement frequency response and determination of main resonance frequencies.