11 resultados para VeriStand, Custom devices, Hardware in the loop, LabView, FPGA, ECU
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Triple-gate devices are considered a promising solution for sub-20 nm era. Strain engineering has also been recognized as an alternative due to the increase in the carriers mobility it propitiates. The simulation of strained devices has the major drawback of the stress non-uniformity, which cannot be easily considered in a device TCAD simulation without the coupled process simulation that is time consuming and cumbersome task. However, it is mandatory to have accurate device simulation, with good correlation with experimental results of strained devices, allowing for in-depth physical insight as well as prediction on the stress impact on the device electrical characteristics. This work proposes the use of an analytic function, based on the literature, to describe accurately the strain dependence on both channel length and fin width in order to simulate adequately strained triple-gate devices. The maximum transconductance and the threshold voltage are used as the key parameters to compare simulated and experimental data. The results show the agreement of the proposed analytic function with the experimental results. Also, an analysis on the threshold voltage variation is carried out, showing that the stress affects the dependence of the threshold voltage on the temperature. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Xylanases (EC 3.2.1.8 endo-1,4-glycosyl hydrolase) catalyze the hydrolysis of xylan, an abundant hemicellulose of plant cell walls. Access to the catalytic site of GH11 xylanases is regulated by movement of a short beta-hairpin, the so-called thumb region, which can adopt open or closed conformations. A crystallographic study has shown that the D11F/R122D mutant of the GH11 xylanase A from Bacillus subtilis (BsXA) displays a stable "open" conformation, and here we report a molecular dynamics simulation study comparing this mutant with the native enzyme over a range of temperatures. The mutant open conformation was stable at 300 and 328 K, however it showed a transition to the closed state at 338 K. Analysis of dihedral angles identified thumb region residues Y113 and T123 as key hinge points which determine the open-closed transition at 338 K. Although the D11F/R122D mutations result in a reduction in local inter-intramolecular hydrogen bonding, the global energies of the open and closed conformations in the native enzyme are equivalent, suggesting that the two conformations are equally accessible. These results indicate that the thumb region shows a broader degree of energetically permissible conformations which regulate the access to the active site region. The R122D mutation contributes to the stability of the open conformation, but is not essential for thumb dynamics, i.e., the wild type enzyme can also adapt to the open conformation.
Resumo:
Prosthetic meshes are commonly used to correct abdominal wall defects. However, the inflammatory reaction induced by these devices in the peritoneum is not completely understood. We hypothesized that nitric oxide (NO), produced by nitric oxide synthase 2 (NOS2) may modulate the response induced by mesh implants in the abdominal wall and, consequently, affect the outcome of the surgical procedure. Polypropylene meshes were implanted in the peritoneal side of the abdominal wall in wild-type and NOS2-deficient (NOS2(-/-)) mice. After 15 days tissues around the mesh implant were collected, and inflammatory markers (the cytokine interleukin 1 beta (IL-1 beta) and NO) and tissue remodeling (collagen and metalloproteinases (MMP) 2 and 9) were analyzed. The lack of NOS2-derived NO induced a higher incidence of visceral adhesions at the mesh implantation site compared with wild-type mice that underwent the same procedure (P < 0.05). Additionally, higher levels of IL-1 beta were present in the mesh-implanted NOS2(-/-) animals compared with control and wild-type mice. Mesh implantation induced collagen I and III deposition, but in smaller amounts in NOS2(-/-) mice. MMP-9 activity after the surgical procedure was similarly increased in both groups. Conversely, MMP-2 activity was unchanged in mesh-implanted wild-type mice, but was significantly increased in NOS2(-/-) mice (P < 0.01), due to decreased S-nitrosylation of the enzyme in these animals. We conclude that NOS2-derived NO is crucial for an adequate response to and integration of polypropylene mesh implants in the peritoneum. NO deficiency results in a prolonged inflammatory reaction to the mesh implant, and reduced collagen deposition may contribute to an increased incidence of visceral adhesions. (C) 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Resumo:
The present report describes an 8-year-old gelding presenting with signs of severe abdominal pain. After performing a thorough physical examination, including rectal palpation and additional diagnostic tests, an exploratory laparotomy was recommended. The jejunum was found herniated through the gastrosplenic ligament, and the stomach was severely distended with gas. Given a poor prognosis, the horse was euthanized on the table. At necropsy, the stomach appeared dilated, with an 180 horizontal gastric torsion, from left (lateral) to right (medial), dividing the organ into dorsal and ventral compartments. We believe that the chronic traction exerted by an incarcerated and distended loop of jejunum, in the dorsal aspect of the gastrosplenic ligament, associated with trauma during episodes of intense rolling, enlarged the rent until it ruptured. Because of this rupture, the lateral dorsal aspect of the stomach became unattached, predisposing it to the torsion. (C) 2012 Elsevier Inc. All rights reserved.
Resumo:
The aim of this research was to test the hypothesis that treatment with intra-oral appliances with different occlusal designs was beneficial in the management of pain of masticatory muscles compared with a control group. A total of 51 patients were analysed according to the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) to obtain the diagnosis of masticatory myofascial pain (MMP). The sample was then randomly divided into three groups: group I (n = 21) wore a full coverage acrylic stabilisation occlusal splint; group II (n = 16) wore an anterior device nociceptive trigeminal inhibitory (NTI) system; and group III (n = 14) only received counselling for behavioural changes and self-care (the control group). The first two groups also received counselling. Follow-ups were performed after 2 and 6 weeks and 3 months. In these sessions, patients were evaluated by means of a visual analogue scale (VAS) and pressure pain threshold (PPT) of the masticatory muscles. Possible adverse effects were also recorded, such as discomfort while using the appliance and occlusal changes. The results were analysed with KruskalWallis, anova, Tukeys and Friedman tests, with a significance level of 5%. Group I showed improvement in the reported pain at the first follow-up (2 weeks), whereas for groups II and III, this progress was detected only after 6 weeks and 3 months, respectively. The PPT values did not change significantly. It was concluded that behavioural changes are effective in the management of pain in MMP patients. However, the simultaneous use of occlusal devices appears to produce an earlier improvement.
Resumo:
In the paper of Bonora et al. (2008) [3] we have shown, in the context of type II superstring theory, the classification of the allowed B-field and A-field configurations in the presence of anomaly-free D-branes, the mathematical framework being provided by the geometry of gerbes. Here we complete the discussion considering in detail the case of a stack of D-branes, carrying a non-abelian gauge theory, which was just sketched in Bonora et al. (2008) [3]. In this case we have to mix the geometry of abelian gerbes, describing the B-field, with the one of higher-rank bundles, ordinary or twisted. We describe in detail the various cases that arise according to such a classification, as we did for a single D-brane, showing under which hypotheses the A-field turns out to be a connection on a canonical gauge bundle. We also generalize to the non-abelian setting the discussion about "gauge bundles with non-integral Chern classes", relating them to twisted bundles with connection. Finally, we analyze the geometrical nature of the Wilson loop for each kind of gauge theory on a D-brane or stack of D-branes.
Resumo:
Purpose: Insertion of totally implantable catheters via deep vessels that drain into the superior vena cava results in a lower incidence of venous thrombosis and infection as compared to catheters inserted into femoral and arm veins. Superior vena cava obstruction and inadequacy of the thoracic wall are conditions that prevent reservoir implantation in the chest wall. In this article, we describe a technical innovation that enables the pocket to be fixed in the arm while still allowing access to be achieved via the internal jugular vein. Method: The procedure reported maintains the use of the internal jugular vein for access even when the patient's chest is not suited for reservoir implantation, which is localized in the arm. Results: The procedure was successful and no complications occurred. The position of the catheter tip did not alter with arm movement. Conclusion: The implantation of a port reservoir in the arm following venous access via the internal jugular vein is both safe and convenient.
Resumo:
The opto(electrical) properties and theoretical calculations of polyazomethine with vinylene and phenantridine moieties in the main chain were investigated in the present study. 2,5-Bis(hexyloxy)-1,4-bis[(2,5-bis(hexyloxy)-4-formyl-phenylenevinylene]benzene was polymerized in solution with 3,8-diamino-6-phenylphenanthridine (PAZ-PV-Ph). The temperatures of 5% weight loss (T-5%) of the polyazomethine was observed at 356 degrees C in nitrogen. Electrochemical properties of thin film of the polymer were studied by differential pulse voltammetry. The HOMO level of the PAZ-PV-Ph was at -4.97 eV. The energy band gap (E-g) was detected of approximately similar to 1.9 eV. Energy band gap (E-gopt) was additionally calculated from absorption spectrum and absorption coefficient alpha. The absorption UV-vis spectra of polyazomethine recorded in solution showed a blue shift in comparison with the solid state. HOMO-LUMO levels and E-g were additionally calculated theoretically by density functional theory and molecular simulations of PAZ-PV-Ph are presented. Current density-voltage (J-U) measurements were performed on ITO/PAZ-PV-Ph/Al, ITO/TiO2/PAZ-PV-Ph/Al and ITO/PEDOT/PAZ-PV-Ph:TiO2/Al devices in the dark and during irradiation with light (under illumination of 1000 W m(-2)). The polymer was tested using AFM technique and roughness (R-a, R-ms) along with skew and kurtosis are presented.
Resumo:
Magnetic nanoparticles are promising for a variety of applications, such as biomedical devices, spin electronics, magnetic data storage media, to name a few. However, these goals may only be reached if stable and organized structures are fabricated. In this article, we report on a single-step synthetic route with the coprecipitation method, in which iron oxide magnetic nanoparticles (Fe3O4 NPs) were stabilized in aqueous media using the poly(diallyldimethylammonium chloride) (PDAC) polyelectrolyte. The Fe3O4 NPs had a diameter of ca. 5 nm, according to transmission electron microscopy (TEM) images, being arranged in an inverse spinel structure typical of magnetite. An investigation with infrared spectroscopy indicated that the mechanisms of stabilization in the polymer matrix were based on the interaction between quaternary amide groups from PDAC and the nanoparticle surface. The Fe3O4-PDAC NPs exhibited considerable magnetic susceptibility, with a monotonic increase in the magnetization with decreasing temperature. These Fe3O4-PDAC NPs were immobilized in layer-by-layer (LbL) films, being alternated with layers of poly(vinylsulfonic acid) (PVS). The LbL films were much rougher than typical films made with polyelectrolytes, and Fe3O4-PDAC NPs have been responsible for the high electrocatalytic activity toward H2O2 reduction, with an overpotential shift of 0.69 V. Overall, the stability, magnetic properties and film-forming ability indicate that the Fe3O4-PDAC NPs may be used for nanoelectronics and bioelectrochemical devices requiring reversible and magnetic redox materials.
Resumo:
mitochondrial genomes are generally thought to be under selection for compactness, due to their small size, consistent gene content, and a lack of introns or intergenic spacers. As more animal mitochondrial genomes are fully sequenced, rearrangements and partial duplications are being identified with increasing frequency, particularly in birds (Class Ayes). In this study, we investigate the evolutionary history of mitochondrial control region states within the avian order Psittaciformes (parrots and cockatoos). To this aim, we reconstructed a comprehensive multi-locus phylogeny of parrots, used PCR of three diagnostic fragments to classify the mitochondrial control region state as single or duplicated, and mapped these states onto the phylogeny. We further sequenced 44 selected species to validate these inferences of control region state. Ancestral state reconstruction using a range of weighting schemes identified six independent origins of mitochondrial control region duplications within Psittaciformes. Analysis of sequence data showed that varying levels of mitochondrial gene and tRNA homology and degradation were present within a given clade exhibiting duplications. Levels of divergence between control regions within an individual varied from 0-10.9% with the differences occurring mainly between 51 and 225 nucleotides 3' of the goose hairpin in domain I. Further investigations into the fates of duplicated mitochondrial genes, the potential costs and benefits of having a second control region, and the complex relationship between evolutionary rates, selection, and time since duplication are needed to fully explain these patterns in the mitochondrial genome. (C) 2012 Elsevier Inc. All rights reserved.
Resumo:
Graphene has received great attention due to its exceptional properties, which include corners with zero effective mass, extremely large mobilities, this could render it the new template for the next generation of electronic devices. Furthermore it has weak spin orbit interaction because of the low atomic number of carbon atom in turn results in long spin coherence lengths. Therefore, graphene is also a promising material for future applications in spintronic devices - the use of electronic spin degrees of freedom instead of the electron charge. Graphene can be engineered to form a number of different structures. In particular, by appropriately cutting it one can obtain 1-D system -with only a few nanometers in width - known as graphene nanoribbon, which strongly owe their properties to the width of the ribbons and to the atomic structure along the edges. Those GNR-based systems have been shown to have great potential applications specially as connectors for integrated circuits. Impurities and defects might play an important role to the coherence of these systems. In particular, the presence of transition metal atoms can lead to significant spin-flip processes of conduction electrons. Understanding this effect is of utmost importance for spintronics applied design. In this work, we focus on electronic transport properties of armchair graphene nanoribbons with adsorbed transition metal atoms as impurities and taking into account the spin-orbit effect. Our calculations were performed using a combination of density functional theory and non-equilibrium Greens functions. Also, employing a recursive method we consider a large number of impurities randomly distributed along the nanoribbon in order to infer, for different concentrations of defects, the spin-coherence length.