6 resultados para Velocity prediction

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

We propose a stage-structured integrodifference model for blowflies' growth and dispersion taking into account the density dependence of fertility and survival rates and the non-overlap of generations. We assume a discrete-time, stage-structured, model. The spatial dynamics is introduced by means of a redistribution kernel. We treat one and two dimensional cases, the latter on the semi-plane, with a reflexive boundary. We analytically show that the upper bound for the invasion front speed is the same as in the one-dimensional case. Using laboratory data for fertility and survival parameters and dispersal data of a single generation from a capture-recapture experiment in South Africa, we obtain an estimate for the velocity of invasion of blowflies of the species Chrysomya albiceps. This model predicts a speed of invasion which was compared to actual observational data for the invasion of the focal species in the Neotropics. Good agreement was found between model and observations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work is to predict the temperature distribution of partially submersed umbilical cables under different operating and environmental conditions. The commercial code Fluent (R) was used to simulate the heat transfer and the air fluid flow of part of a vertical umbilical cable near the air-water interface. A free-convective three-dimensional turbulent flow in open-ended vertical annuli was solved. The influence of parameters such as the heat dissipating rate, wind velocity, air temperature and solar radiation was analyzed. The influence of the presence of a radiation shield consisting of a partially submersed cylindrical steel tube was also considered. The air flow and the buoyancy-driven convective heat transfer in the annular region between the steel tube and the umbilical cable were calculated using the standard k-epsilon turbulence model. The radiative heat transfer between the umbilical external surface and the radiation shield was calculated using the Discrete Ordinates model. The results indicate that the influence of a hot environment and intense solar radiation may affect the umbilical cable performance in its dry portion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To determine variables that predict the rate of decline in fetal hemoglobin levels in alloimmune disease. Method Retrospective review of singleton pregnancies that underwent first and second intrauterine transfusions for treatment of fetal anemia because of maternal Rh alloimmunization in a tertiary referral center. Results Forty-one first intrauterine transfusions were performed at 26.1?weeks (standard deviation, SD, 4.6), mean volume of blood transfused was 44.4?mL (SD 23.5) and estimated feto-placental volume expansion was 51.3% (SD 14.5%). Between first and second transfusion, hemoglobin levels reduced on average 0.40?g/dl/day (SD 0.25). Stepwise multiple regression analysis demonstrated that this rate significantly correlated with hemoglobin levels after the first transfusion, the interval between both procedures, and middle cerebral artery systolic velocity before the second transfusion. Conclusion The rate of decline in fetal hemoglobin levels between first and second transfusions in alloimmune disease can be predicted by a combination of hemoglobin levels after the first transfusion, interval between both procedures, and middle cerebral artery systolic velocity before the second transfusion. (C) 2012 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To integrate data from two-dimensional echocardiography (2D ECHO), three-dimensional echocardiography (3D ECHO), and tissue Doppler imaging (TDI) for prediction of left ventricular (LV) reverse remodeling (LVRR) after cardiac resynchronization therapy (CRT). It was also compared the evaluation of cardiac dyssynchrony by TDI and 3D ECHO. Methods: Twenty-four consecutive patients with heart failure, sinus rhythm, QRS = 120 msec, functional class III or IV and LV ejection fraction (LVEF) = 0.35 underwent CRT. 2D ECHO, 3D ECHO with systolic dyssynchrony index (SDI) analysis, and TDI were performed before, 3 and 6 months after CRT. Cardiac dyssynchrony analyses by TDI and SDI were compared with the Pearson's correlation test. Before CRT, a univariate analysis of baseline characteristics was performed for the construction of a logistic regression model to identify the best predictors of LVRR. Results: After 3 months of CRT, there was a moderate correlation between TDI and SDI (r = 0.52). At other time points, there was no strong correlation. Nine of twenty-four (38%) patients presented with LVRR 6 months after CRT. After logistic regression analysis, SDI (SDI > 11%) was the only independent factor in the prediction of LVRR 6 months of CRT (sensitivity = 0.89 and specificity = 0.73). After construction of receiver operator characteristic (ROC) curves, an equation was established to predict LVRR: LVRR =-0.4LVDD (mm) + 0.5LVEF (%) + 1.1SDI (%), with responders presenting values >0 (sensitivity = 0.67 and specificity = 0.87). Conclusions: In this study, there was no strong correlation between TDI and SDI. An equation is proposed for the prediction of LVRR after CRT. Although larger trials are needed to validate these findings, this equation may be useful to candidates for CRT. (Echocardiography 2012;29:678-687)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work is to predict the temperature distribution of partially submersed umbilical cables under different operating and environmental conditions. The commercial code Fluent® was used to simulate the heat transfer and the air fluid flow of part of a vertical umbilical cable near the air-water interface. A free-convective three-dimensional turbulent flow in open-ended vertical annuli was solved. The influence of parameters such as the heat dissipating rate, wind velocity, air temperature and solar radiation was analyzed. The influence of the presence of a radiation shield consisting of a partially submersed cylindrical steel tube was also considered. The air flow and the buoyancydriven convective heat transfer in the annular region between the steel tube and the umbilical cable were calculated using the standard k-ε turbulence model. The radiative heat transfer between the umbilical external surface and the radiation shield was calculated using the Discrete Ordinates model. The results indicate that the influence of a hot environment and intense solar radiation may affect the umbilical cable performance in its dry portion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ria de Aveiro is a large and shallow lagoon on the west coast of Portugal (40º38’N, 8º45´W), characterized by a complex geometry. It includes large areas of intertidal flats and a network of narrow channels which are connected to the Atlantic by an artificial inlet. Tides are the main forcing of the hydrology and physical processes of the lagoon. The deeper areas near the inlet are characterized by strong marine influence through tidal inflow, with high values of current velocity (>1m/s) and tidal range (2–3 m at spring tides), while in remote shallow areas, the circulation and the sea water inflow are reduced. These remote areas are more influenced by fresh waters received from several rivers and several small streams. The Aveiro lagoon is a very important ecosystem but as been used as recipient for various kinds of anthropogenic wastes resulting from the high population density, urban activities and industrial development. One of the most important Portuguese industrial centre is located in the lagoon margins. Ria de Aveiro is a coastal lagoon under huge direct antropization. This system also suffers strong diffuse antropization. This work is related with diffuse antropization linked with chemical pollution which may lead to biological stress and collapse.