12 resultados para Underwater acoustic instrumentation
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Objective: An experimental in vitro study was carried out to evaluate the influence of cortical bone thickness on ultrasound propagation velocity. Methods: Sixty bone plates were used, made from bovine femurs, with thickness ranging from 1 to 6 mm (10 of each). The ultrasound velocity measurements were performed using a device specially designed for this purpose, in an underwater acoustic tank and with direct contact using contact gel. The transducers were positioned in two ways: on opposite sides, with the bone between them, for the transverse measurement; and parallel to each other, on the same side of the bone plates, for the axial measurements. Results: In the axial transmission mode, the ultrasound velocity speed increased with cortical bone thickness, regardless of the distance between the transducers, up to a thickness of 5 mm, then remained constant thereafter. There were no changes in velocity when the transverse measures were made. Conclusion: Ultrasound velocity increased with cortical bone thickness in the axial transmission mode, until the thickness surpasses the wavelength, after which point it remained constant. Level of Evidence: Experimental Study.
Resumo:
The Hubble constant, H-0, sets the scale of the size and age of the Universe and its determination from independent methods is still worthwhile to be investigated. In this article, by using the Sunyaev-Zeldovich effect and X-ray surface brightness data from 38 galaxy clusters observed by Bonamente et al. (Astrophys J 647:25, 2006), we obtain a new estimate of H-0 in the context of a flat Lambda CDM model. There is a degeneracy on the mass density parameter (Omega(m)) which is broken by applying a joint analysis involving the baryon acoustic oscillations (BAO) as given by Sloan Digital Sky Survey. This happens because the BAO signature does not depend on H-0. Our basic finding is that a joint analysis involving these tests yield H-0 = 76.5(-3.33)(+3.35) km/s/mpc and Omega(m) = 0.27(-0.02)(+0.03). Since the hypothesis of spherical geometry assumed by Bonamente et al. is questionable, we have also compared the above results to a recent work where a sample of galaxy clusters described by an elliptical profile was used in analysis.
Resumo:
Invasive species are known to affect native species in a variety of ways, but the effect of acoustic invaders has not been examined previously. We simulated an invasion of the acoustic niche by exposing calling native male white-banded tree frogs (Hypsiboas albomarginatus) to recorded invasive American bullfrog (Lithobates catesbeianus) calls. In response, tree frogs immediately shifted calls to significantly higher frequencies. In the post-stimulus period, they continued to use higher frequencies while also decreasing signal duration. Acoustic signals are the primary basis of mate selection in many anurans, suggesting that such changes could negatively affect the reproductive success of native species. The effects of bullfrog vocalizations on acoustic communities are expected to be especially severe due to their broad frequency band, which masks the calls of multiple species simultaneously.
Resumo:
The present study sought to assess nasal respiratory function in adult patients with maxillary constriction who underwent surgically assisted rapid maxillary expansion (SARME) and to determine correlations between orthodontic measurements and changes in nasal area, volume, resistance, and airflow. Twenty-seven patients were assessed by acoustic rhinometry, rhinomanometry, orthodontic measurements, and use of a visual analogue scale at three time points: before surgery; after activation of a preoperatively applied palatal expander; and 4 months post-SARME. Results showed a statistically significant increase (p < 0.001) in all orthodontic measurements. The overall area of the nasal cavity increased after surgery (p < 0.036). The mean volume increased between assessments, but not significantly. Expiratory and inspiratory flow increased over time (p < 0.001). Airway resistance decreased between assessments (p < 0.004). Subjective analysis of the feeling of breathing exclusively through the nose increased significantly from one point in time to the next (p < 0.05). There was a statistical correlation between increased arch perimeter and decreased airway resistance. Respiratory flow was the only variable to behave differently between sides. The authors conclude that the SARME procedure produces major changes in the oral and nasal cavity; when combined, these changes improve patients' quality of breathing.
Resumo:
A semi-autonomous unmanned underwater vehicle (UUV), named LAURS, is being developed at the Laboratory of Sensors and Actuators at the University of Sao Paulo. The vehicle has been designed to provide inspection and intervention capabilities in specific missions of deep water oil fields. In this work, a method of modeling and identification of yaw motion dynamic system model of an open-frame underwater vehicle is presented. Using an on-board low cost magnetic compass sensor the method is based on the utilization of an uncoupled 1-DOF (degree of freedom) dynamic system equation and the application of the integral method which is the classical least squares algorithm applied to the integral form of the dynamic system equations. Experimental trials with the actual vehicle have been performed in a test tank and diving pool. During these experiments, thrusters responsible for yaw motion are driven by sinusoidal voltage signal profiles. An assessment of the feasibility of the method reveals that estimated dynamic system models are more reliable when considering slow and small sinusoidal voltage signal profiles, i.e. with larger periods and with relatively small amplitude and offset.
Resumo:
OBJECTIVES: The purpose of the study was to acoustically compare the performance of children who do and do not stutter on diadochokinesis tasks in terms of syllable duration, syllable periods, and peak intensity. METHODS: In this case-control study, acoustical analyses were performed on 26 children who stutter and 20 aged-matched normally fluent children (both groups stratified into preschoolers and school-aged children) during a diadochokinesis task: the repetition of articulatory segments through a task testing the ability to alternate movements. Speech fluency was assessed using the Fluency Profile and the Stuttering Severity Instrument. RESULTS: The children who stutter and those who do not did not significantly differ in terms of the acoustic patterns they produced in the diadochokinesis tasks. Significant differences were demonstrated between age groups independent of speech fluency. Overall, the preschoolers performed poorer. These results indicate that the observed differences are related to speech-motor age development and not to stuttering itself. CONCLUSIONS: Acoustic studies demonstrate that speech segment durations are most variable, both within and between subjects, during childhood and then gradually decrease to adult levels by the age of eleven to thirteen years. One possible explanation for the results of the present study is that children who stutter presented higher coefficients of variation to exploit the motor equivalence to achieve accurate sound production (i.e., the absence of speech disruptions).
Resumo:
Objective: Parameters to distinguish normal from deviant voices in early childhood have not been established. The current study sought to auditorily and acoustically characterize voices of children, and to study the relationship between vocal behavior reported by teachers and the presence of vocal aberrations. Methods: One hundred children between four and 6 years and 11 months, who attended early childhood educational institutions, were included. The sample comprised 50 children with normal voices (NVG) and 50 with deviant voices (DVG) matched by gender and age. All participants were submitted to auditory and acoustic analysis of vocal quality and had their vocal behaviors assessed by teachers through a specific protocol. Results: DVG had a higher incidence of breathiness (p < 0.001) and roughness (p < 0.001), but not vocal strain (p = 0.546), which was similar in both groups. The average F-0 was lower in the DVG and a higher noise component was observed in this group as well. Regarding the protocol used "Aspects Related to Phonotrauma - Children's Protocol", higher means were observed for children from DVG in all analyzed aspects and also on the overall means (DVG = 2.15; NVG = 1.12, p < 0.001). In NVG, a higher incidence of vocal behavior without alterations or with discrete alterations was observed, whereas a higher incidence of moderate, severe or extreme alterations of vocal behavior was observed in DVG. Conclusions: Perceptual assessment of voice, vocal acoustic parameters (F-0, noise and GNE), and aspects related to vocal trauma and vocal behavior differentiated the groups of children with normal voice and deviant voice. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
Resumo:
This study sought to evaluate the efficacy of passive ultrasonic irrigation (PUI) on removing the smear layer and debris from root dentin using scanning electron microscopy (SEM). Twenty-five bovine incisors were manually prepared and divided into three groups according to the final irrigation protocol: EDTA, final irrigation with 12 mL of 17% EDTA for 3 minutes followed by 5 mL of 2.5% NaOCl; EDTA=PUI, final flush with 4 mL of 17% EDTA and PUI for 30 seconds. These procedures were repeated three times to standardize the volume of the irrigant. Control group, after preparation, the specimens were irrigated only with 17 mL of 2.5% NaOCl. The roots were fractured and analyzed using SEM. The intragroup analysis revealed that the EDTA=PUI protocol removed a higher amount of debris at the cervical third (P 5 0.03). The intergroup analysis revealed that EDTA=PUI presented the lowest amount of debris at the cervical third (P 5 0.007). Smear layer scores were higher in the control group compared with the EDTA and EDTA=PUI groups, but only at the cervical third (P 50.02). None of the final irrigant protocols completely removed the smear layer and debris. EDTA=PUI only improved the removal of debris at the cervical third.
Resumo:
Since instrumentation of the apical foramen has been suggested for cleaning and disinfection of the cemental canal, selection of the file size and position of the apical foramen have challenging steps. This study analyzed the influence of apical foramen lateral opening and file size can exert on cemental canal instrumentation. Thirty-four human maxillary central incisors were divided in two groups: Group 1 (n=17), without flaring, and Group 2 (n=17), with flaring with LA Axxess burs. K-files of increasing diameters were progressively inserted into the canal until binding at the apical foramen was achieved and tips were visible and bonded with ethyl cyanoacrylate adhesive. Roots/files set were cross-sectioned 5 mm from the apex. Apices were examined by scanning electron microscopy at ×140 and digital images were captured. Data were analyzed statistically by Student’s t test and Fisher’s exact test at 5% significance level. SEM micrographs showed that 19 (56%) apical foramina emerged laterally to the root apex, whereas 15 (44%) coincided with it. Significantly more difficulty to reach the apical foramen was noted in Group 2. Results suggest that the larger the foraminal file size, the more difficult the apical foramen instrumentation may be in laterally emerged cemental canals.
Resumo:
The use of numerical simulation in the design and evaluation of products performance is ever increasing. To a greater extent, such estimates are needed in a early design stage, when physical prototypes are not available. When dealing with vibro-acoustic models, known to be computationally expensive, a question remains, which is related to the accuracy of such models in view of the well-know variability inherent to the mass manufacturing production techniques. In addition, both academia and industry have recently realized the importance of actually listening to a products sound, either by measurements or by virtual sound synthesis, in order to assess its performance. In this work, the scatter of significant parameter variations on a simplified vehicle vibro-acoustic model is calculated on loudness metrics using Monte Carlo analysis. The mapping from the system parameters to sound quality metric is performed by a fully-coupled vibro-acoustic finite element model. Different loudness metrics are used, including overall sound pressure level expressed in dB and Specific Loudness in Sones. Sound quality equivalent sources are used to excite this model and the sound pressure level at the driver's head position is acquired to be evaluated according to sound quality metrics. No significant variation has been perceived when evaluating the system using regular sound pressure level expressed in in dB and dB(A). This happens because of the third-octave filters that averages the results under some frequency bands. On the other hand, Zwicker Loudness presents important variations, arguably, due to the masking effects.
Resumo:
OBJECTIVE: To assess the effects of rapid maxillary expansion on facial morphology and on nasal cavity dimensions of mouth breathing children by acoustic rhinometry and computed rhinomanometry. METHODS: Cohort; 29 mouth breathing children with posterior crossbite were evaluated. Orthodontic and otorhinolaryngologic documentation were performed at three different times, i.e., before expansion, immediately after and 90 days following expansion. RESULTS: The expansion was accompanied by an increase of the maxillary and nasal bone transversal width. However, there were no significant differences in relation to mucosal area of the nose. Acoustic rhinometry showed no difference in the minimal cross-sectional area at the level of the valve and inferior turbinate between the periods analyzed, although rhinomanometry showed a statistically significant reduction in nasal resistance right after expansion, but were similar to pre-treatment values 90 days after expansion. CONCLUSION: The maxillary expansion increased the maxilla and nasal bony area, but was inefficient to increase the nasal mucosal area, and may lessen the nasal resistance, although there was no difference in nasal geometry. Significance: Nasal bony expansion is followed by a mucosal compensation.
Resumo:
Most of the works published on hydrodynamic parameter identification of open-frame underwater vehicles focus their attention almost exclusively on good coherence between simulated and measured responses, giving less importance to the determination of “actual values” for hydrodynamic parameters. To gain insight into hydrodynamic parameter experimental identification of open-frame underwater vehicles, an experimental identification procedure is proposed here to determine parameters of uncoupled and coupled models. The identification procedure includes: (i) a prior estimation of actual values of the forces/torques applied to the vehicle, (ii) identification of drag parameters from constant velocity tests and (iii) identification of inertia and coupling parameters from oscillatory tests; at this stage, the estimated values of drag parameter obtained in item (ii) are used. The procedure proposed here was used to identify the hydrodynamic parameters of LAURS—an unmanned underwater vehicle developed at the University of São Paulo. The thruster–thruster and thruster–hull interactions and the advance velocity of the vehicle are shown to have a strong impact on the efficiency of thrusters appended to open-frame underwater vehicles, especially for high advance velocities. Results of tests with excitation in 1-DOF and 3-DOF are reported and discussed, showing the feasibility of the developed procedure.