4 resultados para URANIUM-MOLYBDENUM FUELS

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Batch combustion of fixed beds of coal, bagasse and blends thereof took place in a pre-heated two-stage electric laboratory furnace, under high-heating rates. The average input fuel/air equivalence ratios were similar for all fuels. The primary and secondary furnace temperatures were varied from 800 degrees C to 1000 degrees C. The effects of fuel blending, combustion staging, and operating furnace temperatures on the emissions from the two fuels were assessed. Furnace effluents were analyzed for carbon dioxide and for products of incomplete combustion (PIC) including CO, volatile and semi-volatile hydrocarbons, as well as particulate matter. Results showed that whereas CO2 was generated during both the observed sequential volatile matter and char combustion phases of the fuels, PICs were only generated during the volatile matter combustion phase. CO2 emissions were the highest from coal, whereas CO and other PIC emissions were the highest from bagasse. Under this particular combustion configuration, combustion of the volatile matter of the blends resulted in lower yields of PIC, than combustion of the volatiles of the neat fuels. Though CO and unburned hydrocarbons from coal as well as from the blends did not exhibit a clear trend with furnace temperature, such emissions from bagasse clearly increased with temperature. The presence of the secondary furnace (afterburner) typically reduced PIC, by promoting further oxidation of the primary furnace effluents. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Persistent harmful scenarios associated with disposal of radioactive waste, high-background radiation areas and severe nuclear accidents are of great concern regarding consequences to both human health and the environment. Of particular concern is the extracellular DNA in aquatic environments contaminated by radiological substances. Strand breaks induced by radiation promote decrease in the transformation efficiency for extracellular DNA. The focus of this study is the quantification of DNA damage following long-term exposure (over one year) to low doses of natural uranium (an alpha particle emitter) to simulate natural conditions, since nothing is known about alpha radiation induced damage to extracellular DNA. A high-resolution Atomic Force Microscope was used to evaluate DNA fragments. Double-stranded plasmid pBS as a model for extracellular DNA was exposed to different amounts of natural uranium. It was demonstrated that low concentrations of U in water (50 to 150 ppm) produce appreciable numbers of double strand breaks, scaling with the square of the average doses. The importance of these findings for environment monitoring of radiological pollution is addressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymeric sensors with improved resistance to organic solvents were produced via the layer-by-layer thin film deposition followed by chemical cross-linking. According to UV-vis spectroscopy, the mass loss of polyaniline/poly(vinyl alcohol) and polyaniline/novolac-type resin based films deposited onto glass slides was less than 20% when they were submitted to successive immersions (up to 3,000 immersion cycles) into commercially available ethanol and gasoline fuel samples. Polyallylamine hydrochloride/nickel tetrasulfonated phthalocyanine films presented similar stability. The electrical responses assessed by impedance spectroscopy of films deposited onto Au-interdigitated microelectrodes were relatively unaffected after continuous or cyclic immersions into both fuels. After these studies, an array including these polymeric sensors was employed to detect adulteration in ethanol and gasoline samples. After principal component analysis, it was possible to conclude that the proposed sensor array is capable to discriminate with remarkable reproducibility ethanol samples containing different amounts of water or else gasoline samples containing different amounts of ethanol. In both examples, more than 90% of data variance was retained in the first principal component. For each type of sample, ethanol and gasoline, it was found a linear correlation between one of the principal components and the sample's composition. These findings allow one to conclude that these films present great potential for the development of reliable and low-cost sensors for fuel analysis in liquid phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different lead sources were identified in a large uranium tailings deposit (5Mton) in the Central Region of Portugal using lead isotopic ratios obtained by ICP-QMS. These ratios helped to clarify the different sources of Pb within the tailings deposit and the impact of the tailings on the surroundings. Ten depth profiles were used for isotopic characterization of the tailings deposit; the lead background signature was evaluated in seven regional rocks (granites) and was defined as being 28 +/- 1 mg kg(-1) for Pb bulk concentration and with isotopic ratios of 1.264(2) for Pb-206/Pb-207 and 1.962(7) for Pb-208/Pb-206. In order to understand Pb isotope distribution within the tailings deposit, simple mixing/mass balance models were used to fit experimental data, involving: (1) the background component; (2) uranium ores (pitchblende) characterized by the ratios Pb-206/Pb-207 of 1.914(3) and Pb-208/Pb-206 of 1.235(2); and (3) an unknown Pb source (named 'Fonte 5') characterized by the ratios Pb-206/Pb-207 of 3.079(7) and Pb-208/Pb-206 of 0.715(1). This unknown source showed high radiogenic ratios found in the water of some tailings depth profiles located in a very specific position in the dump. In terms of isotopic characterization, 69% of the deposit material resulted from the background source, 25% from uranium minerals and only 6% from other uranium mines in the region. Finally, the environment impact revealed that the pollution was focused only in the beginning of the stream and not in the surroundings, nor in the groundwater system. The lead in the water was found only in colloidal form with a clear pitchblende signature. Those data revealed possible remobilization phenomena along the bedside and margins of the watercourse.