5 resultados para Tests accuracy
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
The grading of structural lumber besides contributing for increasing the structure's safety, due to the reduction of the material variability, also allows its rational use. Due to the good correlation between strength and bending stiffness, the latter has been used in estimating the mechanical strength of lumber pieces since the 60's. For industrial application, there are equipment and techniques to evaluate the bending stiffness of lumber, through dynamic tests such as the longitudinal vibration technique, also known as stress wave, and the transverse vibration technique. This study investigated the application of these two techniques in the assessment of the modulus of elasticity in bending of Teca beams (Tectona grandis), from reforestation, and of the tropical species Guajara (Micropholis venulosa). The modulus of elasticity estimated by dynamic tests showed good correlation with the modulus measured in the static bending test. Meantime, we observed that the accuracy of the longitudinal vibration technique was significantly reduced in the evaluation of the bending stiffness of Teca pieces due to the knots existing in this species.
Resumo:
We propose a new general Bayesian latent class model for evaluation of the performance of multiple diagnostic tests in situations in which no gold standard test exists based on a computationally intensive approach. The modeling represents an interesting and suitable alternative to models with complex structures that involve the general case of several conditionally independent diagnostic tests, covariates, and strata with different disease prevalences. The technique of stratifying the population according to different disease prevalence rates does not add further marked complexity to the modeling, but it makes the model more flexible and interpretable. To illustrate the general model proposed, we evaluate the performance of six diagnostic screening tests for Chagas disease considering some epidemiological variables. Serology at the time of donation (negative, positive, inconclusive) was considered as a factor of stratification in the model. The general model with stratification of the population performed better in comparison with its concurrents without stratification. The group formed by the testing laboratory Biomanguinhos FIOCRUZ-kit (c-ELISA and rec-ELISA) is the best option in the confirmation process by presenting false-negative rate of 0.0002% from the serial scheme. We are 100% sure that the donor is healthy when these two tests have negative results and he is chagasic when they have positive results.
Resumo:
Facial reconstruction is a method that seeks to recreate a person's facial appearance from his/her skull. This technique can be the last resource used in a forensic investigation, when identification techniques such as DNA analysis, dental records, fingerprints and radiographic comparison cannot be used to identify a body or skeletal remains. To perform facial reconstruction, the data of facial soft tissue thickness are necessary. Scientific literature has described differences in the thickness of facial soft tissue between ethnic groups. There are different databases of soft tissue thickness published in the scientific literature. There are no literature records of facial reconstruction works carried out with data of soft tissues obtained from samples of Brazilian subjects. There are also no reports of digital forensic facial reconstruction performed in Brazil. There are two databases of soft tissue thickness published for the Brazilian population: one obtained from measurements performed in fresh cadavers (fresh cadavers' pattern), and another from measurements using magnetic resonance imaging (Magnetic Resonance pattern). This study aims to perform three different characterized digital forensic facial reconstructions (with hair, eyelashes and eyebrows) of a Brazilian subject (based on an international pattern and two Brazilian patterns for soft facial tissue thickness), and evaluate the digital forensic facial reconstructions comparing them to photos of the individual and other nine subjects. The DICOM data of the Computed Tomography (CT) donated by a volunteer were converted into stereolitography (STL) files and used for the creation of the digital facial reconstructions. Once the three reconstructions were performed, they were compared to photographs of the subject who had the face reconstructed and nine other subjects. Thirty examiners participated in this recognition process. The target subject was recognized by 26.67% of the examiners in the reconstruction performed with the Brazilian Magnetic Resonance Pattern, 23.33% in the reconstruction performed with the Brazilian Fresh Cadavers Pattern and 20.00% in the reconstruction performed with the International Pattern, in which the target-subject was the most recognized subject in the first two patterns. The rate of correct recognitions of the target subject indicate that the digital forensic facial reconstruction, conducted with parameters used in this study, may be a useful tool. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The current cosmological dark sector (dark matter plus dark energy) is challenging our comprehension about the physical processes taking place in the Universe. Recently, some authors tried to falsify the basic underlying assumptions of such dark matterdark energy paradigm. In this Letter, we show that oversimplifications of the measurement process may produce false positives to any consistency test based on the globally homogeneous and isotropic ? cold dark matter (?CDM) model and its expansion history based on distance measurements. In particular, when local inhomogeneity effects due to clumped matter or voids are taken into account, an apparent violation of the basic assumptions (Copernican Principle) seems to be present. Conversely, the amplitude of the deviations also probes the degree of reliability underlying the phenomenological DyerRoeder procedure by confronting its predictions with the accuracy of the weak lensing approach. Finally, a new method is devised to reconstruct the effects of the inhomogeneities in a ?CDM model, and some suggestions of how to distinguish between clumpiness (or void) effects from different cosmologies are discussed.
Resumo:
Objective: The aim of this study was to evaluate, ex vivo, the precision of five electronic root canal length measurement devices (ERCLMDs) with different operating systems: the Root ZX, Mini Apex Locator, Propex II, iPex, and RomiApex A-15, and the possible influence of the positioning of the instrument tips short of the apical foramen. Material and Methods: Forty-two mandibular bicuspids had their real canal lengths (RL) previously determined. Electronic measurements were performed 1.0 mm short of the apical foramen (-1.0), followed by measurements at the apical foramen (0.0). The data resulting from the comparison of the ERCLMD measurements and the RL were evaluated by the Wilcoxon and Friedman tests at a significance level of 5%. Results: Considering the measurements performed at 0.0 and -1.0, the precision rates for the ERCLMDs were: 73.5% and 47.1% (Root ZX), 73.5% and 55.9% (Mini Apex Locator), 67.6% and 41.1% (Propex II), 61.7% and 44.1% (iPex), and 79.4% and 44.1% (RomiApex A-15), respectively, considering ±0.5 mm of tolerance. Regarding the mean discrepancies, no differences were observed at 0.0; however, in the measurements at -1.0, the iPex, a multi-frequency ERCLMD, had significantly more discrepant readings short of the apical foramen than the other devices, except for the Propex II, which had intermediate results. When the ERCLMDs measurements at -1.0 were compared with those at 0.0, the Propex II, iPex and RomiApex A-15 presented significantly higher discrepancies in their readings. Conclusions: Under the conditions of the present study, all the ERCLMDs provided acceptable measurements at the 0.0 position. However, at the -1.0 position, the ERCLMDs had a lower precision, with statistically significant differences for the Propex II, iPex, and RomiApex A-15.