10 resultados para Teenagers with visual disabilities

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We tested the short-term effects of a nonrigid tool, identified as an "anchor system" (e.g., ropes attached to varying weights resting on the floor), on the postural stabilization of blindfolded adults with and without intellectual disabilities (ID). Participants held a pair of anchors one in each hand, under three weight conditions (250 g, 500 g and 1,000 g), while they performed a restricted balance task (standing for 30 s on a balance beam placed on top of a force platform). These conditions were called anchor practice trials. Before and after the practice trials, a condition without anchors was tested. Control practice groups, who practiced blocks of trials without anchors, included individuals with and without ID. The anchor system improved subjects' balance during the standing task, for both groups. For the control groups, the performance of successive trials in the condition without the anchor system showed no improvement in postural stability. The individuals with intellectual disability, as well as their peers without ID, used the haptic cues of nonrigid tools (i.e., the anchor system) to stabilize their posture, and the short-term stabilizing effects appeared to result from their previous use of the anchor system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate whether there are visual and neurophysical decrements in workers with low exposure to Hg vapor. Methods: Visual fields, contrast sensitivity, color vision, and neuropsychological functions were measured in 10 workers (32.5 +/- 8.5 years) chronically exposed to Hg vapor (4.3 +/- 2.8 years; urinary Hg concentration 22.3 +/- 9.3 mu g/g creatinine). Results: For the worst eyes, we found altered visual field thresholds, lower contrast sensitivity, and color discrimination compared with controls (P < 0.05). There were no significant differences between Hg-exposed subjects and controls on. neuropsychological tests. Nevertheless, duration of exposure was statistically correlated to verbal memory and depression scores. Conclusions: Chronic exposure to Hg vapor at currently accepted safety levels was found to be associated with visual losses but not with neuropsychological dysfunctions in the sample of workers studied. (J Occup Environ Med. 2009,51:1403-1412)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the retinal nerve fiber layer measurements with time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT), and to test the diagnostic ability of both technologies in glaucomatous patients with asymmetric visual hemifield loss. Methods: 36 patients with primary open-angle glaucoma with visual field loss in one hemifield (affected) and absent loss in the other (non-affected), and 36 age-matched healthy controls had the study eye imaged with Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, California, USA) and 3 D OCT-1000 (Topcon, Tokyo, Japan). Peripapillary retinal nerve fiber layer measurements and normative classification were recorded. Total deviation values were averaged in each hemifield (hemifield mean deviation) for each subject. Visual field and retinal nerve fiber layer "asymmetry indexes" were calculated as the ratio between affected versus non-affected hemifields and corresponding hemiretinas. Results: Retinal nerve fiber layer measurements in non-affected hemifields (mean [SD] 87.0 [17.1] mu m and 84.3 [20.2] mu m, for TD and SD-OCT, respectively) were thinner than in controls (119.0 [12.2] mu m and 117.0 [17.7] mu m, P<0.001). The optical coherence tomography normative database classified 42% and 67% of hemiretinas corresponding to non-affected hemifields as abnormal in TD and SD-OCT, respectively (P=0.01). Retinal nerve fiber layer measurements were consistently thicker with TD compared to SD-OCT. Retinal nerve fiber layer thickness asymmetry index was similar in TD (0.76 [0.17]) and SD-OCT (0.79 [0.12]) and significantly greater than the visual field asymmetry index (0.36 [0.20], P<0.001). Conclusions: Normal hemifields of glaucoma patients had thinner retinal nerve fiber layer than healthy eyes, as measured by TD and SD-OCT. Retinal nerve fiber layer measurements were thicker with TD than SD-OCT. SD-OCT detected abnormal retinal nerve fiber layer thickness more often than TD-OCT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An association between memory and executive dysfunction (ED) has been demonstrated in patients with mixed neurological disorders. We aimed to investigate the impact of ED in memory tasks of children with temporal lobe epilepsy (TLE). We evaluated 36 children with TLE and 28 controls with tests for memory, learning, attention, mental flexibility, and mental tracking. Data analysis was composed of comparison between patients and controls in memory and executive function; correlation between memory and executive function tests; and comparison between patients with mild and severe ED in memory tests. Children with TLE had worse performance in focused attention, immediate and delayed recall, phonological memory, mental tracking, planning, and abstraction. Planning, abstraction, and mental tracking were correlated with visual and verbal memory. Children with severe ED had worse performance in verbal and visual memory and learning tests. This study showed that ED was related to memory performance in children with TLE. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho tem por objetivo investigar e delimitar formas de interação e disputas sociais presentes no movimento paralímpico brasileiro, relativos aos processos de classificação de atletas, com base em conceitos de Pierre Bourdieu. A metodologia utilizada fundamentou-se em entrevistas semiestruturadas com quatro atletas (com deficiência física ou visual, praticantes de diversas modalidades: natação, goalball, rugby e basquete em cadeira de rodas) e quatro dirigentes (2 atuantes em funções técnicas e 2 em funções administrativas do Comitê Paralímpico Brasileiro). A análise de dados apoiou-se no método Discurso do Sujeito Coletivo e suas ferramentas metodológicas (expressões-chave; ideias centrais; ancoragens; instrumentos de análise de discurso). Destacam-se como resultados: os protocolos de classificação, assim como a atuação e formação de novos classificadores, são motivo de tensões sociais neste espaço; Os classificadores exercem importante poder simbólico no subcampo; Demais agentes, como treinadores e atletas, têm suas possibilidades de ascensão diminuídas por condições sociais desfavoráveis..

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To measure heterochromatic flicker electroretinograms (ERGs) at high (36 Hz) and intermediate (12 Hz) temporal frequencies to evaluate luminance and cone opponent responses, respectively, in glaucoma eyes with (perimetric) and without (preperimetric) visual field defects. METHODS. Flicker ERGs were recorded from one randomly chosen dilated eye of 32 patients (mean age, 61 +/- 11 years; 15 men, 17 women) from the Erlangen Glaucoma Registry and from 24 healthy volunteers (mean age, 43 +/- 11 years; 14 men, 10 women). Red and green light-emitting diodes in a Ganzfeld stimulator were sine wave-modulated in counterphase. The responses were measured at 36 Hz, the frequency at which ERGs reflect activity of the luminance pathway, and at 12 Hz, the frequency at which ERGs reflect chromatic activity. RESULTS. Response amplitudes were similar in glaucoma patients and controls. Phase differences were observed in patients with visual field defects (perimetric) compared with the control group at 36 and 12 Hz in the first harmonic and second harmonic responses. Patients without visual field defects (preperimetric) showed phase differences for the second harmonic component at 36 Hz. No age effect on response amplitudes and phases was found in any of the subject groups (controls and patients). CONCLUSIONS. The responses displayed phase differences but not amplitude differences in perimetric glaucoma patients at both 36 and 12 Hz, suggesting that both magnocellular and parvocellular pathways are affected. Preperimetric glaucoma patients also showed phase differences. The response phase may be sensitive to early dysfunction of the inner retina. (ClinicalTrials.gov number, NCT00494923.) (Invest Ophthalmol Vis Sci. 2011;52:6757-6765) DOI:10.1167/iovs.11-7538

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Restricted stimulus control refers to discrimination learning with atypical limitations in the range of controlling stimuli or stimulus features In the study reported here 4 normally capable individuals and 10 individuals with Intellectual disabilities (ID) performed two-sample delayed matching to sample Sample stimulus observing was recorded with an eye tracking apparatus High accuracy scores indicated stimulus control by both sample stimuli for the 4 nondisabled participants and 4 participants with ID and eye tracking data showed reliable observing of all stimuli Intermediate accuracy scores indicated restricted stimulus control for the remaining 6 participants Their eye tracking data showed that errors were related to failures to observe sample stimuli and relatively brief observing durations Five of these participants were then given interventions designed to improve observing behavior For 4 participants the interventions resulted initially in elimination of observing failures increased observing durations and Increased accuracy For 2 of these participants contingencies sufficient to maintain adequate observing were not always sufficient to maintain high accuracy subsequent procedure modifications restored It however For the 5th participant initial improvements in observing were not accompanied by improved accuracy in apparent Instance of observing without attending accuracy improved only after an additional intervention that imposed contingencies on observing behavior Thus interventions that control observing behavior seem necessary but may not always be sufficient for the remediation of restricted stimulus control

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are several electrophysiological systems available commercially. Usually, control groups are required to compare their results, due to the differences between display types. Our aim was to examine the differences between CRT and LCD/TFT stimulators used in pattern VEP responses performed according to the ISCEV standards. We also aimed to check different contrast values toward thresholds. In order to obtain more precise results, we intended to measure the intensity and temporal response characteristics of the monitors with photometric methods. To record VEP signals, a Roland RetiPort electrophysiological system was used. The pattern VEP tests were carried out according to ISCEV protocols on a CRT and a TFT monitor consecutively. Achromatic checkerboard pattern was used at three different contrast levels (maximal, 75, 25%) using 1A degrees and 15` check sizes. Both CRT and TFT displays were luminance and contrast matched, according to the gamma functions based on measurements at several DAC values. Monitor-specific luminance parameters were measured by means of spectroradiometric instruments. Temporal differences between the displays` electronic and radiometric signals were measured with a device specifically built for the purpose. We tested six healthy control subjects with visual acuity of at least 20/20. The tests were performed on each subject three times on different days. We found significant temporal differences between the CRT and the LCD monitors at all contrast levels and spatial frequencies. In average, the latency times were 9.0 ms (+/- 3.3 ms) longer with the TFT stimulator. This value is in accordance with the average of the measured TFT input-output temporal difference values (10.1 +/- A 2.2 ms). According to our findings, measuring the temporal parameters of the TFT monitor with an adequately calibrated measurement setup and correcting the VEP data with the resulting values, the VEP signals obtained with different display types can be transformed to be comparable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the association between noise levels present in preschool institutions and vocal disorders among educators. METHODS: Cross-sectional study conducted in 2009 with 28 teachers from three preschool institutions located in the city of Sao Paulo (Southeastern Brazil). Sound pressure levels were measured according to Brazilian Technical Standards Association, with the use of a sound level meter. The averages were classified according to the levels of comfort, discomfort, and auditory damage proposed by the Pan American Health Organization. The educators underwent voice evaluation: self-assessment with visual analogue scale, auditory perceptual evaluation using the GRBAS scale, and acoustic analysis utilizing the Praat program. To analyze the association between noise and voice evaluation, descriptive statistics and the chi-square test were employed, with significance of 10% due to sample size. RESULTS: The teachers' age ranged between 21 and 56 years. The noise average was 72.7 dB, considered as damage 2. The professionals' vocal self-assessment ranked an average of 5.1 on the scale, being considered as moderate alteration. In the auditory-perceptual assessment, 74% presented vocal alteration, especially hoarseness; of these, 52% were considered mild alterations. In the acoustic assessment the majority presented fundamental frequency below the expected level. Averages for jitter, shimmer and harmonic-noise ratio showed alterations. An association between the presence of noise between the harmonics and vocal disorders was observed. CONCLUSIONS: There is an association between presence of noise between the harmonics and vocal alteration, with high noise levels. Although most teachers presented mild voice alteration, the self-evaluation showed moderate alteration, probably due to the difficulty in projection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background Despite new brain imaging techniques that have improved the study of the underlying processes of human decision-making, to the best of our knowledge, there have been very few studies that have attempted to investigate brain activity during medical diagnostic processing. We investigated brain electroencephalography (EEG) activity associated with diagnostic decision-making in the realm of veterinary medicine using X-rays as a fundamental auxiliary test. EEG signals were analysed using Principal Components (PCA) and Logistic Regression Analysis Results The principal component analysis revealed three patterns that accounted for 85% of the total variance in the EEG activity recorded while veterinary doctors read a clinical history, examined an X-ray image pertinent to a medical case, and selected among alternative diagnostic hypotheses. Two of these patterns are proposed to be associated with visual processing and the executive control of the task. The other two patterns are proposed to be related to the reasoning process that occurs during diagnostic decision-making. Conclusions PCA analysis was successful in disclosing the different patterns of brain activity associated with hypothesis triggering and handling (pattern P1); identification uncertainty and prevalence assessment (pattern P3), and hypothesis plausibility calculation (pattern P2); Logistic regression analysis was successful in disclosing the brain activity associated with clinical reasoning success, and together with regression analysis showed that clinical practice reorganizes the neural circuits supporting clinical reasoning.