4 resultados para Technological Plan of Education
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
The objective of the present study was to verify, based on the analysis of student portfolio narratives, if the four pillars of education were approached in the class "Comprehensiveness in health care", part of the integrated curriculum of the Baccalaureate in Nursing Program of the University of Sao Paulo at Ribeirao Preto College of Nursing. A qualitative, documental study was performed using 46 portfolios constructed during the classes. Data collection was performed using an assessment tool that contained items addressing cognitive and affective dimensions. The data were submitted to thematic categorical analysis using the pillars of education as predefined categories. The results show that the pillars of education were, apparently, included in the class. Despite the present study findings, no evidence was found that the expected competencies were actually discussed among students and faculty, according to the records regarding the evaluations of each pedagogical cycle of the studied class.
Resumo:
This paper estimates the impact of the use of structured methods on the quality of education for students in primary public school in Brazil. Structured methods encompass a range of pedagogical and managerial instruments applied in the educational system. In recent years, several municipalities in the state of Sao Paulo have contracted out private educational providers to implement these structured methods in their schooling systems. Their pedagogical proposal involves structuring of curriculum content, development of teacher and student textbooks, and the training and supervision of teachers anti instructors. Using a difference-in-differences estimation strategy, we find that the 4th- and 8th-grade students in the municipalities with structured methods performed better in Portuguese and mathematics than did students in municipalities not exposed to these methods. We find no differences in passing rates. A robustness test supports the assumption that there is no unobserved municipal characteristics associated with proficiency changes over time that may affect the results. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Background: Acute respiratory distress syndrome (ARDS) is associated with high in-hospital mortality. Alveolar recruitment followed by ventilation at optimal titrated PEEP may reduce ventilator-induced lung injury and improve oxygenation in patients with ARDS, but the effects on mortality and other clinical outcomes remain unknown. This article reports the rationale, study design, and analysis plan of the Alveolar Recruitment for ARDS Trial (ART). Methods/Design: ART is a pragmatic, multicenter, randomized (concealed), controlled trial, which aims to determine if maximum stepwise alveolar recruitment associated with PEEP titration is able to increase 28-day survival in patients with ARDS compared to conventional treatment (ARDSNet strategy). We will enroll adult patients with ARDS of less than 72 h duration. The intervention group will receive an alveolar recruitment maneuver, with stepwise increases of PEEP achieving 45 cmH(2)O and peak pressure of 60 cmH2O, followed by ventilation with optimal PEEP titrated according to the static compliance of the respiratory system. In the control group, mechanical ventilation will follow a conventional protocol (ARDSNet). In both groups, we will use controlled volume mode with low tidal volumes (4 to 6 mL/kg of predicted body weight) and targeting plateau pressure <= 30 cmH2O. The primary outcome is 28-day survival, and the secondary outcomes are: length of ICU stay; length of hospital stay; pneumothorax requiring chest tube during first 7 days; barotrauma during first 7 days; mechanical ventilation-free days from days 1 to 28; ICU, in-hospital, and 6-month survival. ART is an event-guided trial planned to last until 520 events (deaths within 28 days) are observed. These events allow detection of a hazard ratio of 0.75, with 90% power and two-tailed type I error of 5%. All analysis will follow the intention-to-treat principle. Discussion: If the ART strategy with maximum recruitment and PEEP titration improves 28-day survival, this will represent a notable advance to the care of ARDS patients. Conversely, if the ART strategy is similar or inferior to the current evidence-based strategy (ARDSNet), this should also change current practice as many institutions routinely employ recruitment maneuvers and set PEEP levels according to some titration method.
Resumo:
This paper is the first part of an extensive work focusing the technological development of steel fiber reinforced concrete pipes (FRCP). Here is presented and discussed the experimental campaign focusing the test procedure and the mechanical behavior obtained for each of the dosages of fiber used. In the second part ("Steel fiber reinforced concrete pipes. Part 2: Numerical model to simulate the crushing test"), the aspects of FRCP numerical modeling are presented and analyzed using the same experimental results in order to be validated. This study was carried out trying to reduce some uncertainties related to FRCP performance and provide a better condition to the use of these components. In this respect, an experimental study was carried out using sewage concrete pipes in full scale as specimens. The diameter of the specimens was 600 mm, and they had a length of 2500 mm. The pipes were reinforced with traditional bars and different contents of steel fibers in order to compare their performance through the crushing test. Two test procedures were used in that sense. In the 1st Series, the diameter displacement was monitored by the use of two LVDTs positioned at both extremities of the pipes. In the 2nd Series, just one LVDT is positioned at the spigot. The results shown a more rigidity response of the pipe during tests when the displacements were measured at the enlarged section of the socket. The fiber reinforcement was very effective, especially when low level of displacement was imposed to the FRCP. At this condition, the steel fibers showed an equivalent performance to superior class pipes made with traditional reinforced. The fiber content of 40 kg/m3 provided a hardening behavior for the FRCP, and could be considered as equivalent to the critical volume in this condition.