5 resultados para Teachers – Continuous Formation

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In mass spectrometric (MS) systems with electrospray ionization (ESI), the sample can be analyzed coupled to separation systems (such as liquid chromatography or capillary electrophoresis) or simply by direct infusion. The greatest benefit of the type of injection is the possibility of continuous use of small amounts of samples over a long period of time. This extended analysis time allows a complete study of fragmentation by mass spectrometry, which is critical for structure elucidation of new compounds, or when using an ion trap mass analyzer. The injector filled with the sample is placed at the ESI source inlet creating an electric field suitable for the continuous formation of a spray (solvent and sample) and consequently, the gradual and even release of the sample. For the formation of the spray, is necessary that the injector end is metalized. The formation of a bilayer of titanium and gold provided an excellent attachment of the film, resulting in a nanoinjector for ionization/spray formation in the system for MS. The nanoinjectors showed high repeatability and stability over 100 min by continuous sampling with 10 mu L of sample.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Polarized magnetophotoluminescence is employed to study the energies and occupancies of four lowest Landau levels in a couple quantum Hall GaAs/AlGaAs double quantum well. As a result, a magnetic field-induced redistribution of charge over the Landau levels manifesting to the continuous formation of the charge density wave and direct evidence for the symmetric-antisymmetric gap shrinkage at v = 3 are found. The observed interlayer charge exchange causes depolarization of the ferromagnetic ground state.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In mass spectrometric (MS) systems with electrospray ionization (ESI), the sample can be analyzed coupled to separation systems (such as liquid chromatography or capillary electrophoresis) or simply by direct infusion. The greatest benefit of the type of injection is the possibility of continuous use of small amounts of samples over a long period of time. This extended analysis time allows a complete study of fragmentation by mass spectrometry, which is critical for structure elucidation of new compounds, or when using an ion trap mass analyzer. The injector filled with the sample is placed at the ESI source inlet creating an electric field suitable for the continuous formation of a spray (solvent and sample) and consequently, the gradual and even release of the sample. For the formation of the spray, is necessary that the injector end is metalized. The formation of a bilayer of titanium and gold provided an excellent attachment of the film, resulting in a nanoinjector for ionization/spray formation in the system for MS. The nanoinjectors showed high repeatability and stability over 100 min by continuous sampling with 10 µL of sample.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Silicified stromatolites have been described in the Permian Teresina Formation, Passa Dois Group, of the Parana Basin. These stromatolites occur as blocks in the Fazenda Monte Alegre area at the headwaters of the creek known as Corrego Catanduva in the municipality of Angatuba. These blocks originate from the Serra de Angatuba region and were recognized in a road that was cut in the midst of sandstones and siltites. The stromatolites are isolated bioherms that are domed to subspherical with a flat base in profile and a rounded to lenticular shape in plan view. The stromatolites exhibit a reddish coloration and are composed of microcrystalline quartz. Lamination is continuous, non-columnar, and anastomosed, showing parallel to divergent growth; however, divergent columns also occur, especially at the tops of the bioherms. The lamination is fine and well preserved, with alternating light and dark laminas. Microfossils of filamentous cyanobacteria are preserved and were related to the genera Microcoleus and Rivularia. Silicified bivalves occur in association with the stromatolites and are preserved in the form of coquina beds and rare isolated specimens within the bioherms. The described specimens belong to the Pinzonella illusa biozone, with representatives of the species Pinzonella illusa, Angatubia cowperesioides, and Houldausiella elongata. The formation environment of these stromatolites is associated with tidal plains of shallow, brackish, relatively calm, warm waters of good luminosity with the presence of weak currents. There was likely a low level of predation, and the environment may have been hypersaline. The coquina beds associated with the stromatolites indicate a probable proximal tempestite, i.e., they were formed near the coastline. The stromatolites were originally composed of carbonates, although these were replaced by silica during early diagenesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, we present a numerical study of the use of reconfigurable arrays (RCA) for vibro-acoustography (VA) beam formation. A parametric study of the aperture selection, number of channels, number of elements, focal distance, and steering parameters is presented to show the feasibility and evaluate the performance of VA imaging based on RCA. The transducer aperture was based on two concentric arrays driven by two continuous-wave or toneburst signals at slightly different frequencies. The mathematical model considers a homogeneous, isotropic, inviscid medium. The point-spread function of the system is calculated based on angular spectrum methods using the Fresnel approximation for rectangular sources. Simulations considering arrays with 50 x 50 to 200 x 200 elements with number of channels varying in the range of 32 to 128 are evaluated to identify the best configuration for VA. Advantages of two-dimensional and RCA arrays and aspects related to clinical importance of the RCA implementation in VA, such as spatial resolution, image frame rate, and commercial machine implementation, are discussed. It is concluded that RCA transducers can produce spatial resolution similar to confocal transducers and steering is possible in the elevational and azimuthal planes. Optimal settings for number of elements, number of channels, maximum steering, and focal distance are suggested for VA clinical applications. Furthermore, an optimization for beam steering based on the channel assignment is proposed for balancing the contribution of the two waves in the steered focus.