16 resultados para Tandem repeat

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nitric oxide (NO), produced by endothelial nitric oxide synthase (eNOS), is a potent vasodilator and plays a prominent role in regulating the cardiovascular system. Decreased basal NO release may predispose to cardiovascular diseases. Evidence suggests that the 27 nt repeat polymorphism of the intron 4 in the eNOS gene may regulate eNOS expression. On the other hand, some recent reports strongly suggest an association between methylmercury (MeHg) exposures and altered NO synthesis. In the present study, we investigate the contribution of the 27-pb tandem repeat polymorphism on nitric oxide production, which could enhance susceptibility to cardiovascular disease in the MeHg-exposed study population. Two-hundred-two participants (98 men and 104 women), all chronically exposed to MeHg through fish consumption were examined. Mean blood Hg concentration and nitrite plasma concentration were 50.5 +/- 35.4 mu g/L and 251.4 +/- 106.3 nM, respectively. Mean systolic and diastolic blood pressure were 120.1 +/- 19.4 mm Hg and 72.0 +/- 10.6 mm Hg, respectively. Mean body mass index was 24.5 +/- 4.3 kg/m(2) and the mean heart rate was 69.8 +/- 11.8 bpm. There were no significant differences in age, arterial blood pressure, body mass index or cardiac frequency between genotype groups (all P>0.05). However, we observed different nitrite concentrations in the genotypes groups, with lower nitrite levels for the 4a4a genotype carriers. Age, gender and the presence of intron 4 polymorphism contributed to nitrite reduction as a result of blood Hg concentration. Taken together, our results show that the 27 nt repeat polymorphism of the intron 4 in the eNOS gene increases susceptibility to cardiovascular diseases after MeHg exposure by modulating nitric oxide levels. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The identification of Leptospira clinical isolates through genotyping and serotyping, besides the recognition of its reservoirs, are important tools for understanding the epidemiology of leptospirosis, and they are also keys for identifying new species and serovars. Fourteen clinical isolates from animals were characterized by means of single enzyme amplified length polymorphism, variable number of tandem repeat analysis, pulsed field gel electrophoresis, and serotyping. All isolates were identified as Leptospira interrogans, serovar Canicola. Infections by this serovar occur in urban regions, where dogs represent the main maintenance hosts, whereas bovine and swine may act as reservoirs of serovar Canicola in rural areas. Both urban and rural aspects of leptospirosis, and the role of domestic animals as maintenance hosts, cannot be neglected in developing and developed countries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Short tandem DNA repeats and telomerase compose the telomere structure in the vast majority of eukaryotic organisms. However, such a conserved organisation has not been found in dipterans. While telomeric DNA in Drosophila is composed of specific retrotransposons, complex terminal tandem repeats are present in chromosomes of Anopheles and chironomid species. In the sciarid Rhynchosciara americana, short repeats (16 and 22 bp long) tandemly arrayed seem to reach chromosome ends. Moreover, in situ hybridisation data using homopolymeric RNA probes suggested in this species the existence of a third putative chromosome end repeat enriched with (dA).(dT) homopolymers. In this work, chromosome micro-dissection and PCR primed by homopolymeric primers were employed to clone these repeats. Named T-14 and 93 % AT-rich, the repetitive unit is 14 bp long and appears organised in tandem arrays. It is localised in five non-centromeric ends and in four interstitial bands of R. americana chromosomes. To date, T-14 is the shortest repeat that has been characterised in chromosome ends of dipterans. As observed for short tandem repeats identified previously in chromosome ends of R. americana, the T-14 probe hybridised to bridges connecting non-homologous polytene chromosome ends, indicative of close association of T-14 repeats with the very end of the chromosomes. The results of this work suggest that R. americana represents an additional example of organism provided with more than one DNA sequence that is able to reach chromosome termini.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Patients with acute myeloid leukemia (AML) and FLT3/internal tandem duplication (FLT3/ITD) have poor prognosis if treated with chemotherapy only. Whether this alteration also affects outcome after allogeneic hematopoietic stem-cell transplantation (HSCT) remains uncertain. Patients and Methods We analyzed 206 patients who underwent HLA-identical sibling and matched unrelated HSCTs reported to the European Group for Blood and Marrow Transplantation with a diagnosis of AML with normal cytogenetics and data on FLT3/ITD (present: n = 120, 58%; absent: n = 86, 42%). Transplantations were performed in first complete remission (CR) after myeloablative conditioning. Results Compared with FLT3/ITD-negative patients, FLT3/ITD-positive patients had higher median leukocyte count at diagnosis (59 v 21 x 10(9)/L; P < .001) and shorter interval from CR to transplantation (87 v 99 days; P = .04). Other characteristics were similar in the two groups. At 2 years, relapse incidence (RI; +/- standard deviation) was higher (30% +/- 5% v 16% +/- 5%; P = .006) and leukemia-free survival (LFS) lower (58% +/- 5% v 71% +/- 6%; P = .04) in FLT3/ITD-positive compared with FLT3/ITD-negative patients. In multivariate analyses, FLT3/ITD led to increased RI (hazard ratio [HR], 3.4; 95% CI, 1.46 to 7.94; P = .005), as did older age, female sex, shorter interval between CR and transplantation, and higher number of chemotherapy courses before achieving CR. FLT3/ITD positivity was associated with decreased LFS (HR, 0.37; 95% CI, 0.19 to 0.73; P = .002), along with older age and higher number of chemotherapy courses before achieving CR. Conclusion FLT3/ITD adversely affected the outcome of HSCT in the same direction it does after chemotherapy; despite this, more than half of the patients harboring this mutation who received transplants were alive and leukemia free at 2 years. To further improve the results, use of FLT3 inhibitors before or after HSCT deserves investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, a fast, sensitive and robust method to quantify dextromethorphan, dextrorphan and doxylamine in human plasma using deuterated internal standards (IS) is described. The analytes and the IS were extracted from plasma by a liquid-liquid extraction (LLE) using diethyl-ether/hexane (80/20, v/v). Extracted samples were analyzed by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Chromatographic separation was performed by pumping the mobile phase (acetonitrile/water/formic acid (90/9/1, v/v/v) during 4.0 min at a flow-rate of 1.5 mL min(-1) into a Phenomenex Gemini (R) C18, 5 mu m analytical column (150 x 4.6 mm id.). The calibration curve was linear over the range from 0.2 to 200 ng mL(-1) for dextromethorphan and doxylamine and 0.05 to 10 ng mL(-1) for dextrorphan. The intra-batch precision and accuracy (%CV) of the method ranged from 2.5 to 9.5%, and 88.9 to 105.1%, respectively. Method inter-batch precision (%CV) and accuracy ranged from 6.7 to 10.3%, and 92.2 to 107.1%, respectively. The run-time was for 4 min. The analytical procedure herein described was used to assess the pharmacokinetics of dextromethorphan, dextrorphan and doxylamine in healthy volunteers after a single oral dose of a formulation containing 30 mg of dextromethorphan hydrobromide and 12.5 mg of doxylamine succinate. The method has high sensitivity, specificity and allows high throughput analysis required for a pharmacokinetic study. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate the relationship of short tandem repeats (STR) near genes involved in the leptin-melanocortin pathway with body mass index (BMI) and leptinemia. Subjects and methods: Anthropometric variables and leptinemia were measured in 100 obese and 110 non-obese individuals. D1S200, D2S1788, DS11912, and D18S858 loci were analyzed by PCR and high-resolution electrophoresis. Results: Overall STR allele frequencies were similar between the obese and non-obese group (p > 0.05). Individual alleles D1S200 (17), D11S912 (43), D18S858 (11/12) were associated with obesity (p < 0.05). Individuals carrying these alleles showed higher BMI than non-carriers (p < 0.05). Moreover, a relationship between D18S858 11/12 alleles and increased waist circumference was found (p = 0.040). On the other hand, leptinemia was not influenced by the studied STRs (p > 0.05). Conclusions: D1S200, D11S912, and D18S858 loci are associated with increased BMI and risk for obesity in this sample. Arq Bras Endocrinol Metab. 2012;56(1):47-53

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In mass spectrometric (MS) systems with electrospray ionization (ESI), the sample can be analyzed coupled to separation systems (such as liquid chromatography or capillary electrophoresis) or simply by direct infusion. The greatest benefit of the type of injection is the possibility of continuous use of small amounts of samples over a long period of time. This extended analysis time allows a complete study of fragmentation by mass spectrometry, which is critical for structure elucidation of new compounds, or when using an ion trap mass analyzer. The injector filled with the sample is placed at the ESI source inlet creating an electric field suitable for the continuous formation of a spray (solvent and sample) and consequently, the gradual and even release of the sample. For the formation of the spray, is necessary that the injector end is metalized. The formation of a bilayer of titanium and gold provided an excellent attachment of the film, resulting in a nanoinjector for ionization/spray formation in the system for MS. The nanoinjectors showed high repeatability and stability over 100 min by continuous sampling with 10 mu L of sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: to investigate factors associated with repeat pregnancies among adolescents in a tertiary hospital in the city of Sao Paulo, Brazil. Background: Teenage mothers present a high risk of repeat pregnancies during adolescence. Most of these pregnancies are unplanned. Methods: A cross-sectional study conducted in a tertiary hospital in Sao Paulo, Brazil. The study population included 745 first-time pregnancies and 170 two or more times pregnant teenagers hospitalised for childbirth. Logistic regression models were used to identify independent factors associated with repeat pregnancy in this population. Results: Older age at first pregnancy was associated with a decreased risk of repeat pregnancies (odds ratio and 95% confidence interval 0.78 (0.68-0.89)). Prenatal examinations (0.13 (0.05-0.32)), higher education (0.83 (0.76-0.91)) and higher monthly income (0.79 (0.67-0.95)) were also protective against repeat pregnancies. Those who used contraceptives (2.76 (1.80-4.21)) and lived with their partners (2.44 (1.53-3.88)) had an increased risk of becoming pregnant more than once. Conclusion: Preventive programmes aiming to avoid repeat pregnancies in adolescents should not be restricted to the transmission of information. Behavioural changes in family planning must include access not only to adequate information but also to adequate healthcare, contraceptive methods, education and training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fast and sensitive method for the simultaneous determination of Sudan dyes (I, II, III, and IV) in food samples was developed for the first time using partial filling micellar electrokinectic chromatography-mass spectrometry (MEKC-MS). The use of MEKC was essential to achieve the separation of these neutral analytes, while the partial filling technique was necessary to avoid the contamination of the ion source with non-volatile micelles. MEKC separation and MS detection conditions were optimized in order to achieve a fast, efficient, and sensitive separation of the four dyes. Filling 25% of the capillary with an MEKC solution containing 40 mM ammonium bicarbonate, 25 mM SDS, and 32.5% (v/v) acetonitrile, a baseline separation of the four azo-dyes was obtained in 10 min. Tandem MS was investigated in order to improve the sensitivity and selectivity of the analysis. Limits of detection (LOD) values 5, 8, 15, and 29 times better were obtained for Sudan III, I, II, and IV, respectively, using partial filling MEKC-MS/MS instead of partial filling MEKC-MS. Under optimized conditions, LOD from 0.05 to 0.2 mu g/mL were obtained. The suitability of the developed method was demonstrated through the fast and sensitive determination of Sudan I, II, III, and IV in spiked chilli powder samples. This determination could not be achieved by MEKC-UV due to the existence of several interfering compounds from the matrix.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carvedilol is an antihypertensive drug available as a racemic mixture. (-)-(S)-carvedilol is responsible for the nonselective beta-blocker activity but both enantiomers present similar activity on a1-adrenergic receptor. To our knowledge, this is the first study of carvedilol enantiomers in human plasma using a chiral stationary phase column and liquid chromatography with tandem mass spectrometry. The method involves plasma extraction with diisopropyl ether using metoprolol as internal standard and direct separation of the carvedilol enantiomers on a Chirobiotic T (R) (Teicoplanin) column. Protonated ions [M + H]+ and their respective ion products were monitored at transitions of 407 > 100 for the carvedilol enantiomers and 268 > 116 for the internal standard. The quantification limit was 0.2 ng ml-1 for both enantiomers in plasma. The method was applied to study enantioselectivity in the pharmacokinetics of carvedilol administered as a single dose of 25 mg to a hypertensive patient. The results showed a higher plasma concentration of (+)-(R)-carvedilol (AUC08 205.52 vs. 82.61 (ng h) ml-1), with an enantiomer ratio of 2.48. Chirality, 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Piplartine (PPTN) is an alkaloid amide found in Piper species that presents different activities. PPTN determination in rat plasma is necessary to better understand its biological effects. The aim of this study was to develop a sensitive LC-MS/MS method for the determination of PPTN in rat plasma. The performance criteria for linearity, sensitivity, precision, accuracy, recovery, and stability have been assessed and were within the recommended guidelines. The validated method proved to be suitable in a pilot study of PPTN kinetic disposition in rat plasma after a single intraperitoneal dose, and represents an appropriate tool to further pharmacokinetic studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corrole and four of its isomers with subtle structural changes promoted by exchange of nitrogen and carbon atoms in the corrole ring have been studied by traveling wave ion mobility mass spectrometry and collision induced dissociation experiments. Significant differences in shapes and charge distributions for their protonated molecules were found to lead to contrasting gas phase mobilities, most particularly for corrorin, the most "confused" isomer. Accordingly, corrorin was predicted by B3LYP/6-31g(d,p) and collisional cross section calculations to display the most compact tri-dimensional structure, whereas NCC4 and corrole were found to be the most planar isomers. Better resolution between the corrole isomers was achieved using the more polarizable and massive CO2 as the drift gas. Sequential losses of HF molecules were found to dominate the dissociation chemistry of the protonated molecules of these corrole isomers, but their unique structures caused contrasting labilities towards CID, whereas NCC4 showed a peculiar and structurally diagnostic loss of NH3, allowing its prompt differentiation from the other isomers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Piplartine (PPTN) is an alkaloid amide found in Piper species that presents different activities. PPTN determination in rat plasma is necessary to better understand its biological effects. The aim of this study was to develop a sensitive LC-MS/MS method for the determination of PPTN in rat plasma. The performance criteria for linearity, sensitivity, precision, accuracy, recovery, and stability have been assessed and were within the recommended guidelines. The validated method proved to be suitable in a pilot study of PPTN kinetic disposition in rat plasma after a single intraperitoneal dose, and represents an appropriate tool to further pharmacokinetic studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In mass spectrometric (MS) systems with electrospray ionization (ESI), the sample can be analyzed coupled to separation systems (such as liquid chromatography or capillary electrophoresis) or simply by direct infusion. The greatest benefit of the type of injection is the possibility of continuous use of small amounts of samples over a long period of time. This extended analysis time allows a complete study of fragmentation by mass spectrometry, which is critical for structure elucidation of new compounds, or when using an ion trap mass analyzer. The injector filled with the sample is placed at the ESI source inlet creating an electric field suitable for the continuous formation of a spray (solvent and sample) and consequently, the gradual and even release of the sample. For the formation of the spray, is necessary that the injector end is metalized. The formation of a bilayer of titanium and gold provided an excellent attachment of the film, resulting in a nanoinjector for ionization/spray formation in the system for MS. The nanoinjectors showed high repeatability and stability over 100 min by continuous sampling with 10 µL of sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid, sensitive and specific method for quantifying hydroxocobalamin in human plasma using paracetamol as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (ethanol 100%; -20°C). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS-MS). Chromatography was performed on Prevail C8 3 μm, analytical column (2.1×100 mm i.d.). The method had a chromatographic run time of 3.4 min and a linear calibration curve over the range 5-400 ng.mL-1 (r>0.9983). The limit of quantification was 5 ng.mL-1. The method was also validated without the use of the internal standard. The precision in the intra-batch validation with IS was 9.6%, 8.9%, 1.0% and 2.8% whereas without IS was 9.2%, 8.2%, 1.8% and 1.5% for 5, 15, 80 and 320 ng/mL, respectively. The accuracy in intra-batch validation with IS was 108.9%, 99.9%, 98.9% and 99.0% whereas without IS was 101.1%, 99.3%, 97.5% and 92.5% for 5, 15, 80 and 320 ng/mL, respectively. The precision in the inter-batch validation with IS was 9.4%, 6.9%, 4.6% and 5.5% whereas without IS was 10.9%, 6.4%, 5.0% and 6.2% for 5, 15, 80 and 320 ng/mL, respectively. The accuracy in inter-batch validation with IS was 101.9%, 104.1%, 103.2% and 99.7% whereas without IS was 94.4%, 101.2%, 101.6% and 96.0% for 5, 15, 80 and 320 ng/mL, respectively. This HPLC-MS-MS procedure was used to assess the pharmacokinetics of Hydroxo cobalamin following intramuscular injection 5000 μg in healthy volunteers of both sexes (10 males and 10 females). The volunteers had the following clinical characteristics (according to gender and expressed as mean ± SD [range]): males: age: 32.40 ± 8.00 y [23.00-46.00], height: 1.73 ± 0.07 m [1.62-1.85], body weight: 72.48 ± 10.22 Kg [60.20- 88.00]; females: age: 28.60 ± 9.54 y [18.00-44.00], height: 1.60 ± 0.05 m [1.54-1.70], body weight: 58.64 ± 6.09 Kg [51.70- 66.70]. The following pharmacokinetic parameters were obtained from the hydroxocobalamin plasma concentration vs. time curves: AUClast, T1/2, Tmax, Vd, Cl, Cmax and Clast. The pharmacokinetic parameters were 120 (± 25) ng/mL for Cmax, 2044 (± 641) ng.h/mL for AUClast, 8 (± 3.2) ng.mL-1 for Clast, 38 (± 15.8) hr for T1/2 and 2.5 (range 1-6) hr for Tmax. Female volunteers presented significant (p=0.0136) lower AUC (1706 ± 704) ng.h/mL) and larger (p=0.0205) clearance (2.91 ± 1.41 L/hr), as compared to male 2383 ± 343 ng.h/mL and 1.76 ± 0.23 L/hr, respectively. These pharmacokinetic differences could explain the higher prevalence of vitamin B12 deficiency in female patients. The method described validated well without the use of the internal standard and this approach should be investigated in other HPLC-MS-MS methods.