12 resultados para TENS

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Based on evidence showing that electrical stimulation of the nervous system is an effective method to decrease chronic neurogenic pain, we aimed to investigate whether the combination of 2 methods of electrical stimulation-a method of peripheral stimulation [transcutaneous electrical nerve stimulation (TENS)] and a method of noninvasive brain stimulation (transcranial direct current stimulation (tDCS)]-induces greater pain reduction as compared with tDCS alone and sham stimulation. Methods: We performed a preliminary, randomized, sham-controlled, crossover, clinical study in which 8 patients were randomized to receive active tDCS/active TENS (""tDCS/TENS"" group), active tDCS/sham TENS (""tDCS"" group), and sham tDCS/sham TENS (""sham"" group) stimulation. Assessments were performed immediately before and after each condition by a blinded rater. Results: The results showed that there was a significant difference in pain reduction across the conditions Of stimulation (P = 0.006). Post hoc tests showed significant pain reduction as compared with baseline after the tDCS/TENS condition [reduction by 36.5% (+/- 10.7), P = 0.004] and the tDCS condition [reduction by 15.5% (+/- 4.9), P = 0.014], but not after sham stimulation (P = 0.35). In addition, tDCS/TENS induced greater pain reduction than tDCS (P = 0.02). Conclusions: The results of this pilot study suggest that the combination of TENS with tDCS has a superior effect compared with tDCS alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcutaneous electrical nerve stimulation (TENS) reduces hyperalgesia and pain. Both low-frequency (LF) and high-frequency (HF) TENS, delivered at the same intensity (90% motor threshold [MT]) daily, result in analgesic tolerance with repeated use by the fifth day of treatment. The current study tested 1) whether increasing intensity by 10% per day prevents the development of tolerance to repeated TENS; and 2) whether lower intensity TENS (50% MT) produces an equivalent reduction in hyperalgesia when compared to 90% MT TENS. Sprague-Dawley rats with unilateral knee joint inflammation (3% carrageenan) were separated according to the intensity of TENS used: sham, 50% LF, 50% HF, 90% LF, 90% HF, and increased intensity by 10% per day (IF and HF). The reduced mechanical withdrawal threshold following the induction of inflammation was reversed by application of TENS applied at 90% MT intensity and increasing intensity for the first 4 days. On the fifth day, the groups that received 90% MT intensity showed tolerance. Nevertheless, the group that received an increased intensity on each day still showed a reversal of the mechanical withdrawal threshold with TENS. These results show that the development of tolerance can be delayed by increasing intensity of TENS. Perspective: Our results showed that increasing intensity in both frequencies of TENS was able to prevent analgesic tolerance. Results from this study suggest that increasing intensities could be a clinical method to prevent analgesic tolerance and contribute to the effective use of TENS in reducing inflammatory pain and future clinical trials. (c) 2012 by the American Pain Society

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: We evaluated the effectiveness of high-frequency transcutaneous electrical nerve stimulation (TENS) as a pain relief resource for primiparous puerpere who had experienced natural childbirth with an episiotomy. Methods: A controlled, randomized clinical study was conducted in a Brazilian maternity ward. Forty puerpere were randomly divided into two groups: TENS high frequency and a no treatment control group. Post-episiotomy pain was assessed in the resting and sitting positions and during ambulation. An 11-point numeric rating scale was performed in three separate evaluations (at the beginning of the study, after 60 min and after 120 min). The McGill pain questionnaire was employed at the beginning and 60 min later. TENS with 100 Hz frequency and 75 mu s pulse for 60 min was employed without causing any pain. Four electrodes ware placed in parallel near the episiotomy site, in the area of the pudendal and genitofemoral nerves. Results: An 11-point numeric rating scale and McGill pain questionnaire showed a significant statistical difference in pain reduction in the TENS group, while the control group showed no alteration in the level of discomfort. Hence, high-frequency TENS treatment significantly reduced pain intensity immediately after its use and 60 min later. Conclusion: TENS is a safe and viable non-pharmacological analgesic resource to be employed for pain relief post-episiotomy. The routine use of TENS post-episiotomy is recommended.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4748519]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The wide variety of molecular architectures used in sensors and biosensors and the large amount of data generated with some principles of detection have motivated the use of computational methods, such as information visualization techniques, not only to handle the data but also to optimize sensing performance. In this study, we combine projection techniques with micro-Raman scattering and atomic force microscopy (AFM) to address critical issues related to practical applications of electronic tongues (e-tongues) based on impedance spectroscopy. Experimentally, we used sensing units made with thin films of a perylene derivative (AzoPTCD acronym), coating Pt interdigitated electrodes, to detect CuCl(2) (Cu(2+)), methylene blue (MB), and saccharose in aqueous solutions, which were selected due to their distinct molecular sizes and ionic character in solution. The AzoPTCD films were deposited from monolayers to 120 nm via Langmuir-Blodgett (LB) and physical vapor deposition (PVD) techniques. Because the main aspects investigated were how the interdigitated electrodes are coated by thin films (architecture on e-tongue) and the film thickness, we decided to employ the same material for all sensing units. The capacitance data were projected into a 2D plot using the force scheme method, from which we could infer that at low analyte concentrations the electrical response of the units was determined by the film thickness. Concentrations at 10 mu M or higher could be distinguished with thinner films tens of nanometers at most-which could withstand the impedance measurements, and without causing significant changes in the Raman signal for the AzoPTCD film-forming molecules. The sensitivity to the analytes appears to be related to adsorption on the film surface, as inferred from Raman spectroscopy data using MB as analyte and from the multidimensional projections. The analysis of the results presented may serve as a new route to select materials and molecular architectures for novel sensors and biosensors, in addition to suggesting ways to unravel the mechanisms behind the high sensitivity obtained in various sensors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims. Spectroscopic, polarimetric, and high spectral resolution interferometric data covering the period 1995-2011 are analyzed to document the transition into a new phase of circumstellar disk activity in the classical Be-shell star 48 Lib. The objective is to use this broad data set to additionally test disk oscillations as the basic underlying dynamical process. Methods. The long-term disk evolution is described using the V/R ratio of the violet and red emission components of H alpha and Br gamma, radial velocities and profiles of He I and optical metal shell lines, as well as multi-band BVRI polarimetry. Single-epoch broad-band and high-resolution interferometric visibilities and phases are discussed with respect to a classical disk model and the given baseline orientations. Results. Spectroscopic signatures of disk asymmetries in 48 Lib vanished in the late nineties but recovered some time between 2004 and 2007, as shown by a new large-amplitude and long-duration V/R cycle. Variations in the radial velocity and line profile of conventional shell lines correlate with the V/R behavior. They are shared by narrow absorption cores superimposed on otherwise seemingly photospheric He I lines, which may form in high-density gas at the inner disk close to the photosphere. Large radial velocity variations continued also during the V/R-quiet years, suggesting that V/R may not always be a good indicator of global density waves in the disk. The comparison of the polarization after the recovery of the V/R activity shows a slight increase, while the polarization angle has been constant for more than 20 years, placing tight limits on any 3-D precession or warping of the disk. The broad H-band interferometry gives a disk diameter of (1.72 +/- 0.2) mas (equivalent to 15 stellar radii), position angle of the disk (50 +/- 9)degrees and a relatively low disk flattening of 1.66 +/- 0.3. Within the errors the same disk position angle is derived from polarimetric observations and from photocenter shifts across Br gamma. The high-resolution interferometric visibility and phase profiles show a double or even multiple-component structure. A preliminary estimate based on the size of the Br gamma emitting region indicates a large diameter for the disk (tens of stellar radii). Overall, no serious contradiction between the observations and the disk-oscillation model could be construed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background With the development of DNA hybridization microarray technologies, nowadays it is possible to simultaneously assess the expression levels of thousands to tens of thousands of genes. Quantitative comparison of microarrays uncovers distinct patterns of gene expression, which define different cellular phenotypes or cellular responses to drugs. Due to technical biases, normalization of the intensity levels is a pre-requisite to performing further statistical analyses. Therefore, choosing a suitable approach for normalization can be critical, deserving judicious consideration. Results Here, we considered three commonly used normalization approaches, namely: Loess, Splines and Wavelets, and two non-parametric regression methods, which have yet to be used for normalization, namely, the Kernel smoothing and Support Vector Regression. The results obtained were compared using artificial microarray data and benchmark studies. The results indicate that the Support Vector Regression is the most robust to outliers and that Kernel is the worst normalization technique, while no practical differences were observed between Loess, Splines and Wavelets. Conclusion In face of our results, the Support Vector Regression is favored for microarray normalization due to its superiority when compared to the other methods for its robustness in estimating the normalization curve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background Treatment efficacy of physical agents in osteoarthritis of the knee (OAK) pain has been largely unknown, and this systematic review was aimed at assessing their short-term efficacies for pain relief. Methods Systematic review with meta-analysis of efficacy within 1–4 weeks and at follow up at 1–12 weeks after the end of treament. Results 36 randomised placebo-controlled trials (RCTs) were identified with 2434 patients where 1391 patients received active treatment. 33 trials satisfied three or more out of five methodological criteria (Jadad scale). The patient sample had a mean age of 65.1 years and mean baseline pain of 62.9 mm on a 100 mm visual analogue scale (VAS). Within 4 weeks of the commencement of treatment manual acupuncture, static magnets and ultrasound therapies did not offer statistically significant short-term pain relief over placebo. Pulsed electromagnetic fields offered a small reduction in pain of 6.9 mm [95% CI: 2.2 to 11.6] (n = 487). Transcutaneous electrical nerve stimulation (TENS, including interferential currents), electro-acupuncture (EA) and low level laser therapy (LLLT) offered clinically relevant pain relieving effects of 18.8 mm [95% CI: 9.6 to 28.1] (n = 414), 21.9 mm [95% CI: 17.3 to 26.5] (n = 73) and 17.7 mm [95% CI: 8.1 to 27.3] (n = 343) on VAS respectively versus placebo control. In a subgroup analysis of trials with assumed optimal doses, short-term efficacy increased to 22.2 mm [95% CI: 18.1 to 26.3] for TENS, and 24.2 mm [95% CI: 17.3 to 31.3] for LLLT on VAS. Follow-up data up to 12 weeks were sparse, but positive effects seemed to persist for at least 4 weeks after the course of LLLT, EA and TENS treatment was stopped. Conclusion TENS, EA and LLLT administered with optimal doses in an intensive 2–4 week treatment regimen, seem to offer clinically relevant short-term pain relief for OAK.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Eastern South America, a series of fault-bounded sedimentary basins that crop out from Southern Uruguay to Southeastern Brazil were formed after the main collisional deformation of the Brasiliano Orogeny and record the tectonic events that affected the region from the Middle Ediacaran onwards. We address the problem of discerning the basin-forming tectonics from the later deformational events through paleostress analysis of more than 600 fault-slip data, mainly from the Camaquã Basin (Southern Brazil), sorted by stratigraphic level and cross-cutting relationships of superposed striations, and integrated with available stratigraphic and geochronological data. Our results show that the Camaquã Basin was formed by at least two distinct extensional events, and that rapid paleostress changes took place in the region a few tens of million years after the major collision (c.a. 630 Ma), probably due to the interplay between local active extensional tectonics and the distal effects of the continued amalgamation of plates and terranes at the margins of the still-forming Gondwana Plate. Preliminary paleostress data from the Castro Basin and published data from the Itajaí Basin suggest that these events had a regional nature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: A disfunção temporomandibular (DTM) é um termo que descreve um grupo de doenças que afetam funcionalmente o aparelho mastigatório, particularmente a musculatura mastigatória e a articulação temporomandibular (ATM). Tem etiologias múltiplas e tratamentos específicos, entre os quais a estimulação elétrica nervosa transcutânea (TENS). O objetivo deste artigo é o de revisar a literatura científica sobre o uso da TENS em pacientes com DTM. CONTEÚDO: Estudos epidemiológicos mostram que aproximadamente 75% da população apresentam algum sinal de DTM, enquanto 33% possuem ao menos um sintoma. Sempre que possível deve-se tratar a causa da dor, caso não se consiga estabelecer a sua etiologia, inicia-se com procedimentos menos invasivos e reversíveis, especialmente nos casos de dor e disfunção muscular. A terapia com TENS consiste na administração de corrente elétrica na superfície cutânea, de modo a relaxar os músculos hiperativos e promover o alívio da dor. CONCLUSÃO: Embora existam controvérsias quanto ao uso de TENS para o controle da dor crônica, seu uso na dor muscular mastigatória continua relevante. Entretanto, é fundamental o diagnóstico preciso para evitar uso inadequado. São necessários ainda estudos randomizados controlados que incluam amostras selecionadas para homogeneizar o uso de TENS em pacientes com DTM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Piezoelectric ceramics, such as PZT, can generate subnanometric displacements, bu t in order to generate multi- micrometric displacements, they should be either driven by high electric voltages (hundreds of volts ), or operate at a mechanical resonant frequency (in narrow band), or have large dimensions (tens of centimeters). A piezoelectric flextensional actuator (PFA) is a device with small dimensions that can be driven by reduced voltages and can operate in the nano- and micro scales. Interferometric techniques are very adequate for the characterization of these devices, because there is no mechanical contact in the measurement process, and it has high sensitivity, bandwidth and dynamic range. A low cost open-loop homodyne Michelson interferometer is utilized in this work to experimentally detect the nanovi brations of PFAs, based on the spectral analysis of the interfero metric signal. By employing the well known J 1 ...J 4 phase demodulation method, a new and improved version is proposed, which presents the following characteristics: is direct, self-consistent, is immune to fading, and does not present phase ambiguity problems. The proposed method has resolution that is similar to the modified J 1 ...J 4 method (0.18 rad); however, differently from the former, its dynamic range is 20% larger, does not demand Bessel functions algebraic sign correction algorithms and there are no singularities when the static phase shift between the interferometer arms is equal to an integer multiple of  /2 rad. Electronic noise and random phase drifts due to ambient perturbations are taken into account in the analysis of the method. The PFA nanopositioner characterization was based on the analysis of linearity betw een the applied voltage and the resulting displacement, on the displacement frequency response and determination of main resonance frequencies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Cherenkov Telescope Array (CTA) is a new observatory for very high-energy (VHE) gamma rays. CTA has ambitions science goals, for which it is necessary to achieve full-sky coverage, to improve the sensitivity by about an order of magnitude, to span about four decades of energy, from a few tens of GeV to above 100 TeV with enhanced angular and energy resolutions over existing VHE gamma-ray observatories. An international collaboration has formed with more than 1000 members from 27 countries in Europe, Asia, Africa and North and South America. In 2010 the CTA Consortium completed a Design Study and started a three-year Preparatory Phase which leads to production readiness of CTA in 2014. In this paper we introduce the science goals and the concept of CTA, and provide an overview of the project.