3 resultados para Surrounding bone

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, compromising the whole system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Extended excessive alcohol use causes changes in bone tissue, thus affecting osteogenesis. The objective of this study was to evaluate if demineralized bone matrix (Gen-ox (R)) associated with bone morphogenetic protein (Gen-pro (R)) changes bone neoformation in rats submitted to experimental alcoholism. Forty male rats (Rattus norvegicus) were separated into 2 groups of 20 animals each: Group E1, which received ethyl alcohol at 25% and had the surgical cavity filled in only with blood clot; and Group E2. which received ethyl alcohol at 25% and had the surgical cavity filled in with demineralized bovine cortical bone associated with bone morphogenetic protein. The animals were submitted to a three-week period of gradual adaptation to alcohol, and then continued receiving alcohol at 25% for 90 days, when the surgical cavity was made. After the surgery, the animals continued consuming alcohol until reaching the sacrifice periods of 10, 20, 40, and 60 days, when the tibias were removed for histological processing. Results showed that surgical cavity repair and bone marrow reorganization occurred faster in Group E1 than in Group E2. At the end of the experiment, it was observed that animals in Group E2 had thick bony trabeculae surrounding the implanted material particles and a small area of connective tissue in the surface region. In conclusion, the implanted material did not accelerate bone neoformation, rather it served as a structure for osteogenesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To verify the thickness and level of alveolar bone around the teeth adjacent to the cleft by means of cone beam computed tomography (CBCT) in patients with complete bilateral cleft lip and palate prior to bone graft surgery and orthodontic intervention. Method: The sample comprised 10 patients with complete bilateral cleft lip and palate (five boys and five girls) in the mixed dentition. The mean age was 9.5 years, and all subjects showed a G3 interarch relationship according to the Bauru index. The thickness of alveolar bone surrounding the maxillary incisors and the maxillary canines was measured in CBCT axial section using the software iCAT Xoran System. The distance between the alveolar bone crest and the cement-enamel junction (CEJ) was measured in cross sections. Results: The tomography images showed a thin alveolar bone plate around teeth adjacent to clefts. No bone dehiscence was observed in teeth adjacent to clefts during the mixed dentition. A slight increase in the distance between the alveolar bone crest and the CEJ was observed in the mesial and lingual aspects of canines adjacent to cleft. Conclusion: In patients with BCLP in the mixed dentition, teeth adjacent to the alveolar cleft are covered by a thin alveolar bone plate. However, the level of alveolar bone crest around these teeth seems to be normal, and no bone dehiscence was identified at this age.