13 resultados para Suction
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
This paper presents the results of an experimental study of thermal effects on filter paper calibration curves used to obtain the soil suction. When the temperature is significantly different from ambient values, it is essential to consider the influence of temperature on the filter paper calibration curves to obtain a reliable soil suction measurement. The calibration curve of Whatman No. 42 filter paper was determined at 10 degrees C, 25 degrees C, and 50 degrees C using the vapor equilibrium technique with sodium chloride solutions at different concentrations and the axis translation technique. The experimental results showed a major influence of temperature on the filter paper calibration curves. Using the obtained experimental data a calibration equation was proposed, taking into account the effect of temperature. The obtained calibration curves were then used to determine the soil water retention curve of kaolin clay, which showed lower retention capacity at higher temperatures.
Resumo:
The filter paper method is one of the most commonly used and critiqued techniques for measuring soil suction. However, many aspects related to its use still require some clarification. The results of a comprehensive study on the effect of the contact between the soil grains and soil water and the filter paper are presented herein. We investigated the influence of the equilibration time, the texture of the porous material and the degree of contact, or lack thereof, between the soil grains and the filter paper using Miamian #42 and three different types of porous material. To enhance the difference between the total suction and the matrix suction, osmotic suction was induced by saturating the specimens with a sodium chloride solution.
Resumo:
This paper presents the swelling behaviour of clayey materials under controlled suction imposed both by a Richards chamber and by controlling the relative humidity with concentrated saline solutions. Soil-water characteristic curves (matrix and total) were determined by the filter paper method. The materials under study belong to the Guabirotuba Formation, of Pleistocene age, in the Curitiba Basin in the state of Parana, southern Brazil. Materials under several stages of suction of 5000-40 000 kPa were subjected to swelling tests in an oedometer press. The results indicated that the greater the suction the higher the swelling pressure. However, when swelling tests were carried out with suction variation controlled by relative humidity, in which the increase in moisture was very slow, the samples showed no swelling.
Resumo:
AIM: identify and analyze in the literature the evidence of randomized controlled trials on care related to the suctioning of endotracheal secretions in intubated, critically ill adult patients undergoing mechanical ventilation. METHOD: the search was conducted in the PubMed, EMBASE, CENTRAL, CINAHL and LILACS databases. From the 631 citations found, 17 studies were selected. RESULTS: Evidence was identified for six categories of intervention related to endotracheal suctioning, which were analyzed according to outcomes related to hemodynamic and blood gas alterations, microbial colonization, nosocomial infection, and others. CONCLUSIONS: although the evidence obtained is relevant to the practice of endotracheal aspiration, the risks of bias found in the studies selected compromise the evidence's reliability.
Resumo:
Subsurface drip irrigation that uses an emitter protection system to avoid its clogging by roots and soil particles may be viable compared to a conventional system. The objective of this work was to evaluate the performance of a system with emitter protection, and to compare the results with a system that uses a conventional emitter for subsurface drip irrigation. In the system with protection an inexpensive materials polyethylene hose, microtube, connector, and a dripper to control the flow rate were used; and, in the conventional system a commercial emitter was used. After 12 months of evaluation, the system with protector showed good performance, with relative average flow rate of 0.97 and 0.98 in pots with and without crop, respectively, showing no clogging problems and lower cost. In conventional system relative flow rate of 0.51 and 0.98 were observed in pots with and without crop, respectively, also clogging degree by roots of 49.22%, and emitters with soil inside was observed. Thus, the use of emitter with protection presented feasibility for subsurface drip irrigation, under conditions used in this research.
Resumo:
A central goal in unsaturated soil mechanics research is to create a smooth transition between traditional soil mechanics approaches and an approach that is applicable to unsaturated soils. Undrained shear strength and the liquidity index of reconstituted or remoulded saturated soils are consistently correlated, which has been demonstrated by many studies. In the liquidity index range from 1 (at w(l)) to 0 (at w(p)), the shear strength ranges from approximately 2 kPa to 200 kPa. Similarly, for compacted soil, the shear strength at the plastic limit ranges from 150 kPa to 250 kPa. When compacted at their optimum water content, most soils have a suction that ranges from 20 kPa to 500 kPa; however, in the field, compacted materials are subjected to drying and wetting, which affect their initial suction and as a consequence their shear strength. Unconfined shear tests were performed on five compacted tropical soils and kaolin. Specimens were tested in the as-compacted condition, and also after undergoing drying or wetting. The test results and data from prior literature were examined, taking into account the roles of void ratio, suction, and relative water content. An interpretation of the phenomena that are involved in the development of the undrained shear strength of unsaturated soils in the contexts of soil water retention and Atterberg limits is presented, providing a practical view of the behaviour of compacted soil based on the concept of unsaturated soil. Finally, an empirical correlation is presented that relates the unsaturated state of compacted soils to the unconfined shear strength.
Resumo:
This paper presents laboratory and in situ studies carried out on a 200 000 m(3) large clayey silt compacted embankment. Laboratory studies carried out on undeformed block samples included index tests, strength tests and water retention curves using the filter paper technique. Grain size analyses with and without a deflocculating agent clearly showed the existence of grain clusters, which appear to be naturally formed. Field instrumentation installed at depths from 0.25 m to 1.0 m included tensiometers, equitensiometers, time domain reflectometry and geothermometers. Pluviometer data from a nearby weather station are also used to analyse the field data. The ranges of water content and suction values were measured, both of which correlated well with the pluviometer data. The water retention curves including laboratory and field data showed a bimodal shape, consistent with the presence of microand macropores shown in the grain size analysis.
Resumo:
To evaluate an innovative technique for intrastromal air injection to achieve deep anterior lamellar keratoplasty (DALK) with bare Descemet membrane (DM). Thirty-four eyes with anterior corneal pathology, including 27 with keratoconus, underwent DALK. After 400 mm trephination with a suction trephine, ultrasound pachymetry was performed 0.8 mm internally from the trephination groove in the 11 to 1 o'clock position. In this area, a 2-mm incision was created, parallel to the groove, with a micrometer diamond knife calibrated to 90% depth of the thinnest measurement. A cannula was inserted through the incision and 0.5 mL of air was injected to dissect the DM from the stroma. After peripheral paracentesis, anterior keratectomy was carried out to bare the DM. A 0.25-mm oversized graft was sutured in place. Overall, 94.1% of eyes achieved DALK. Bare DM was achieved in 30 eyes, and a pre-DM dissection was performed in 2 eyes. Air injection was successful in detaching the DM (achieving the big bubble) in 88.2% of the eyes. In keratoconus eyes, the rate was 88.9%. All cases but one required a single air injection to achieve DM detachment. Microperforations occurred in 5 cases: 3 during manual layer-by-layer dissection after air injection failed to detach the DM, 1 during removal of the residual stroma after big-bubble formation, and 1 during the diamond knife incision. Two cases (5.9%) were converted to penetrating keratoplasty because of macroperforations. The technique was reproducible, safe, and highly effective in promoting DALK with bare DM.
Resumo:
The oil industry uses gas separators in production wells as the free gas present in the suction of the pump reduces the pumping efficiency and pump lifetime. Therefore, free gas is one of the most important variables in the design of pumping systems. However, in the literature there is little information on these separators. It is the case of the inverted-shroud gravitational gas separator. It has an annular geometry due to the installation of a cylindrical container in between the well casing and pioduction pipe (tubing). The purpose of the present study is to understand the phenomenology and behavior of inverted-shroud separator. Experimental tests were performed in a 10.5-m-length inclinable glass tube with air and water as working fluids. The water flow rate was in the range of 8.265-26.117 l/min and the average inlet air mass flow rate was 1.1041 kg/h, with inclination angles of 15 degrees, 30 degrees, 45 degrees, 60 degrees, 75 degrees, 80 degrees and 85 degrees. One of the findings is that the length between the inner annular level and production pipe inlet is one of the most important design parameters and based on that a new criterion for total gas separation is proposed. We also found that the phenomenology of the studied separator is not directly dependent on the gas flow rate, but on the average velocity of the free surface flow generated inside the separator. Maps of efficiency of gas separation were plotted and showed that liquid flow rate, inclination angle and pressure difference between casing and production pipe outlet are the main variables related to the gas separation phenomenon. The new data can be used for the development of design tools aiming to the optimized project of the pumping system for oil production in directional wells. (C) 2012 Elsevier Inc. All rights reserved.
Resumo:
Abstract Background The PEEP-ZEEP technique is previously described as a lung inflation through a positive pressure enhancement at the end of expiration (PEEP), followed by rapid lung deflation with an abrupt reduction in the PEEP to 0 cmH2O (ZEEP), associated to a manual bilateral thoracic compression. Aim To analyze PEEP-ZEEP technique's repercussions on the cardio-respiratory system in immediate postoperative artery graft bypass patients. Methods 15 patients submitted to a coronary artery bypass graft surgery (CABG) were enrolled prospectively, before, 10 minutes and 30 minutes after the technique. Patients were curarized, intubated, and mechanically ventilated. To perform PEEP-ZEEP technique, saline solution was instilled into their orotracheal tube than the patient was reconnected to the ventilator. Afterwards, the PEEP was increased to 15 cmH2O throughout 5 ventilatory cycles and than the PEEP was rapidly reduced to 0 cmH2O along with manual bilateral thoracic compression. At the end of the procedure, tracheal suction was accomplished. Results The inspiratory peak and plateau pressures increased during the procedure (p < 0.001) compared with other pressures during the assessment periods; however, they were within lung safe limits. The expiratory flow before the procedure were 33 ± 7.87 L/min, increasing significantly during the procedure to 60 ± 6.54 L/min (p < 0.001), diminishing to 35 ± 8.17 L/min at 10 minutes and to 36 ± 8.48 L/min at 30 minutes. Hemodynamic and oxygenation variables were not altered. Conclusion The PEEP-ZEEP technique seems to be safe, without alterations on hemodynamic variables, produces elevated expiratory flow and seems to be an alternative technique for the removal of bronchial secretions in patients submitted to a CABG.
Resumo:
A irrigação por gotejamento subsuperficial, que utiliza um sistema protetor do emissor para evitar entupimento do mesmo por raiz e partículas sólida do solo, pode ser viável em relação a um sistema convencional. Propôs-se, com este trabalho, avaliar o desempenho de um sistema para proteção de emissor e comparar os resultados com um sistema que utiliza emissor convencional para irrigação por gotejamento subsuperficial. O sistema com protetor foi construído com materiais de baixo custo: mangueira de polietileno, microtubo, conector e um gotejador para controlar a vazão e no sistema convencional utilizou-se um emissor comercial. Após 12 meses de avaliação o sistema com protetor demonstrou bom desempenho com vazão relativa média de 0,97 e 0,98 em vasos com e sem cultura, respectivamente, não apresentando problemas de entupimento e tendo menor custo. No sistema convencional constatou-se vazão relativa de 0,51 e 0,98 em vasos com e sem cultura, respectivamente, grau de entupimento por raiz de 49,22% e emissores com solo em seu interior. Desta forma, o uso do emissor com sistema de proteção indicou viabilidade para irrigação subsuperficial por gotejamento, nas condições desta pesquisa.
Resumo:
OBJETIVO: apresentar uma proposta de protocolo de avaliação do frênulo da língua em bebês com escores. MÉTODO: inicialmente foi realizada uma revisão da literatura relacionada, consultando as bases de dados Web of Science, Pubmed, Embase, All Evidence-Based Medicine Reviews e Scielo, bem como livros textos das áreas de anatomia, odontopediatria e fonoaudiologia. Todos os aspectos julgados relevantes nos trabalhos encontrados foram incluídos na versão inicial, que foi submetida à avaliação de três fonoaudiólogas especialistas em motricidade orofacial, sendo obtida a versão consenso, que foi aplicada em 10 bebês nascidos a termo buscando verificar a exequibilidade do instrumento. RESULTADOS: com base na literatura consultada e no estudo piloto, foi elaborado o protocolo de avaliação do frênulo da língua em bebês. A primeira parte é composta por história clínica contendo questões gerais de identificação e questões específicas sobre antecedentes familiais e amamentação. A segunda parte é composta pelo exame clínico, constituído de avaliação anatomofuncional e avaliação das funções orofaciais. CONCLUSÕES: o protocolo de avaliação do frênulo da língua em bebês foi desenvolvido a partir de uma proposta teórica e depende de sua aplicabilidade para se configurar como um teste validado. Espera-se que o mesmo possa auxiliar os profissionais da saúde a avaliar e diagnosticar as variações anatômicas do frênulo e sua possível interferência na amamentação, norteando condutas eficazes e promovendo uma prática baseada em evidências. A segunda fase deste trabalho deve compreender a pesquisa experimental e a análise estatística dos dados.