35 resultados para Statistical evaluation
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
To refine methods of electroretinographical (ERG) recording for the analysis of low retinal potentials under scotopic conditions in advanced retinal degenerative diseases. Standard Ganzfeld ERG equipment (Diagnosys LLC, Cambridge, UK) was used in 27 healthy volunteers (mean age 28 +/- A SD 8.5 years) to define the stimulation protocol. The protocol was then applied in clinical routine and 992 recordings were obtained from patients (mean age 40.6 +/- A 18.3 years) over a period of 5 years. A blue stimulus with a flicker frequency of 9 Hz was specified under scotopic conditions to preferentially record rod-driven responses. A range of stimulus strengths (0.0000012-6.32 scot. cd s/mA(2) and 6-14 ms flash duration) was tested for maximal amplitudes and interference between rods and cones. Analysis of results was done by standard Fourier Transformation and assessment of signal-to-noise ratio. Optimized stimulus parameters were found to be a time-integrated luminance of 0.012 scot. cd s/mA(2) using a blue (470 nm) flash of 10 ms duration at a repetition frequency of 9 Hz. Characteristic stimulus strength versus amplitude curves and tests with stimuli of red or green wavelength suggest a predominant rod-system response. The 9 Hz response was found statistically distinguishable from noise in 38% of patients with otherwise non-recordable rod responses according to International Society for Clinical Electrophysiology of Vision standards. Thus, we believe this protocol can be used to record ERG potentials in patients with advanced retinal diseases and in the evaluation of potential treatments for these patients. The ease of implementation in clinical routine and of statistical evaluation providing an observer-independent evaluation may further facilitate its employment.
Resumo:
Objectives: To investigate the effect of Si addition on a nanometer-scale roughness Ca and P implant surfaces in a canine tibia model by biomechanical and histomorphometric evaluations. Material and methods: The implant surfaces comprised a resorbable media CaP microblasted (control) and a CaP resorbable media + silica-boost microblasted (experimental) surfaces. Surfaces were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and optical interferometry (IFM) down to the nanometric level. The animal model involved the bilateral placement of control (n = 24) and experimental surface (n = 24) implants along the proximal tibiae of six dogs, remaining in vivo for 2 or 4 weeks. After euthanization, half of the specimens were torquedto- interface failure, and the other half was subjected to histomorphologic and bone-to-implant contact (BIC) evaluation. Torque and BIC statistical evaluation was performed by the Friedman test at 95% level of significance, and comparisons between groups was performed by the Dunn test. Results: IFM and SEM observations depicted comparable roughness parameters for both implant surfaces on the micrometer and nanometer scales. XPS analysis revealed similar chemical composition, except for the addition of Si on the experimental group. Torque-to-interface failure and BIC mean values showed no significant differences (P = 0.25 and 0.51, respectively) at both 2- and 4-week evaluation points for experimental and control groups. Early bone healing histomorphologic events were similar between groups. Conclusions: The experimental surface resulted in not significantly different biomechanical fixation and BIC relative to control. Both surfaces were biocompatible and osseoconductive.
Resumo:
PURPOSE: To investigate the facial symmetry of high and low dose methotrexate (MTX) treated rats submitted to experimentally displaced mandibular condyle fracture through the recording of cephalometric measurements. METHODS: One hundred male Wistar rats underwent surgery using an experimental model of right condylar fracture. Animals were divided into four groups: A - saline solution (1mL/week); B - dexamethasone (DEX) (0,15mg/Kg); C - MTX low dose (3 mg/Kg/week); D - MTX high dose (30 mg/Kg). Animals were sacrificed at 1, 7, 15, 30 and 90 days postoperatively (n=5). Body weight was recorded. Specimens were submitted to axial radiographic incidence, and cephalometric mensurations were made using a computer system. Linear measurements of skull and mandible, as well as angular measurements of mandibular deviation were taken. Data were subjected to statistical analyses among the groups, periods of sacrifice and between the sides in each group (alpha=0.05). RESULTS: Animals regained body weight over time, except in group D. There was reduction in the mandibular length and also changes in the maxilla as well as progressive deviation in the mandible in relation to the skull basis in group D. CONCLUSION: Treatment with high dose methotrexate had deleterious effect on facial symmetry of rats submitted to experimentally displaced condylar process fracture.
Resumo:
The aims of this in vivo study were to compare the effectiveness and color stability of at-home and in-office bleaching techniques and to evaluate whether the use of light sources can alter bleaching results. According to preestablished criteria, 40 patients were selected and randomly divided into four groups according to bleaching treatment: (1) at-home bleaching with 10% carbamide peroxide, (2) in-office bleaching with 35% hydrogen peroxide (HP) without a light source, (3) in-office bleaching with 35% HP with quartz-tungsten-halogen light, and (4) in-office bleaching with 35% HP with a light-emitting diode/laser. Tooth shade was evaluated using the VITA Classical Shade Guide before bleaching as well as after the first and third weeks of bleaching. Tooth shade was evaluated again using the same guide 1 and 6 months after the completion of treatment. The shade guide was arranged to yield scores that were used for statistical comparison. Statistical analysis using the Kruskal-Wallis test showed no significant differences among the groups for any time point (P > .01). There was no color rebound in any of the groups. The bleaching techniques tested were equally effective. Light sources are unnecessary to bleach teeth. (Int J Periodontics Restorative Dent 2012;32:303-309.)
Resumo:
The occurrence of white matter (WM) abnormalities in psychotic disorders has been suggested by several studies investigating brain pathology and diffusion tensor measures, but evidence assessing regional WM morphometry is still scarce and conflicting. In the present study, 122 individuals with first-episode psychosis (FEP) (62 fulfilling criteria for schizophrenia/schizophreniform disorder, 26 psychotic bipolar I disorder, and 20 psychotic major depressive disorder) underwent magnetic resonance imaging, as well as 94 epidemiologically recruited controls. Images were processed with the Statistical Parametric Mapping (SPM2) package, and voxel-based morphometry was used to compare groups (t-test) and subgroups (ANOVA). Initially, no regional WM abnormalities were observed when both groups (overall FEP group versus controls) and subgroups (i.e., schizophrenia/schizophreniform, psychotic bipolar I disorder, psychotic depression, and controls) were compared. However, when the voxelwise analyses were repeated excluding subjects with comorbid substance abuse or dependence, the resulting statistical maps revealed a focal volumetric reduction in right frontal WM, corresponding to the right middle frontal gyral WM/third subcomponent of the superior longitudinal fasciculus, in subjects with schizophrenia/schizophreniform disorder (n = 40) relative to controls (n = 89). Our results suggest that schizophrenia/schizophreniform disorder is associated with right frontal WM volume decrease at an early course of the illness. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Lychnophora salicifolia Mart., which occurs in the Brazilian Cerrado in the states of Bahia and Minas Gerais as well as in the southeast of the state of Goias, is the most widely distributed and also the most polymorphic species of the genus. This plant is popularly known to have anti-inflammatory and analgesic activities. In this work, we have studied the variation in terms of polar metabolites of ninety-three Lychnophora salicifolia Mart, specimens collected from different regions of the Brazilian Cerrado. Identification of the constituents of this mixture was carried out by analysis of the UV spectra and MS data after chromatographic separation. Twenty substances were identified, including chlorogenic acid derivatives, a flavonoid C-glucoside, and other sesquiterpenes. The analytical method was validated, and the reliability and credibility of the results was ensured for the purposes of this study. The concentration range required for analysis of content variability within the analyzed group of specimens was covered with appropriate values of limits of detection and quantitation, as well as satisfactory precision and recovery. A quantitative variability was observed among specimens collected from the same location, but on average they were similar from a chemical viewpoint. In relation to the study involving specimens from different locations, there were both qualitative and quantitative differences among plants collected from different regions of Brazil. Statistical analysis revealed that there is a correlation between geographical localization and polar metabolites profile for specimens collected from different locations. This is evidence that the pattern of metabolites concentration depends on the geographical distribution of the specimens. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Explosives industries are a source of toxic discharge. The aim of this study was to compare organisms sensitivity (Daphnia similis, Danio rerio, Escherichia coli and Pseudomonas putida) in detecting acute toxicity in wastewater from two explosives, 2,4,6-TNT (TNT) and nitrocellulose. The samples were collected from an explosives company in the Paraiba Valley, So Paulo, Brazil. The effluents from TNT and nitrocellulose production were very toxic for tested organisms. Statistical tests indicated that D. similis and D. rerio were the most sensitive organisms for toxicity detection in effluents from 2,4,6-TNT and nitrocellulose production. The P. putida bacteria was the organism considered the least sensitive in indicating toxicity in effluents from nitrocellulose.
Resumo:
Polymorphonuclear leukocyte (PMNL) apoptosis is central to the successful resolution of inflammation. Since Somatic Cell Count (SCC) is an indicator of the mammary gland's immune status, this study sought to clarify the influence that these factors have on each other and on the evolution of the inflammatory process. Milk samples were stained with annexin-V, propidium iodide (PI), primary antibody anti-CH138A. Negative correlation between SCC and PMNL apoptosis was found, and a statistical difference between high SCC group and low SCC group was observed concerning the rate of viable PMNL, apoptotic PMNL, necrotic PMNL and necrotic and/or apoptotic PMNL. Overall, the high cellularity group presented lower proportions of CH138+ cells undergoing apoptosis and higher proportions of viable and necrotic CH138+ cells. Thus, it can be concluded that PMNL apoptosis and SCC are related factors, and that in high SCC, milk apoptosis is delayed. Although there is a greater amount of active phagocytes in this situation, apoptosis' anti-inflammatory effects are decreased, while necrosis' pro-inflammatory effects are increased, which can contribute to chronic inflammation.
Resumo:
Purpose: Few reports have evaluated cumulative survival rates of extraoral rehabilitation and peri-implant soft tissue reaction at long-term follow-up. The objective of this study was to evaluate implant and prosthesis survival rates and the soft tissue reactions around the extraoral implants used to support craniofacial prostheses. Materials and Methods: A retrospective study was performed of patients who received implants for craniofacial rehabilitation from 2003 to 2010. Two outcome variables were considered: implant and prosthetic success. The following predictor variables were recorded: gender, age, implant placement location, number and size of implants, irradiation status in the treated field, date of prosthesis delivery, soft tissue response, and date of last follow-up. A statistical model was used to estimate survival rates and associated confidence intervals. We randomly selected 1 implant per patient for analysis. Data were analyzed using the Kaplan-Meier method and log-rank test to compare survival curves. Results: A total of 150 titanium implants were placed in 56 patients. The 2-year overall implant survival rates were 94.1% for auricular implants, 90.9% for nasal implants, 100% for orbital implants, and 100% for complex midfacial implants (P = .585). The implant survival rates were 100% for implants placed in irradiated patients and 94.4% for those placed in nonirradiated patients (P = .324). The 2-year overall prosthesis survival rates were 100% for auricular implants, 90.0% for nasal implants, 92.3% for orbital implants, and 100% for complex midfacial implants (P = .363). The evaluation of the peri-implant soft tissue response showed that 15 patients (26.7%) had a grade 0 soft tissue reaction, 30 (53.5%) had grade 1, 6 (10.7%) had grade 2, and 5 (8.9%) had grade 3. Conclusions: From this study, it was concluded that craniofacial rehabilitation with extraoral implants is a safe, reliable, and predictable method to restore the patient's normal appearance. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70:1551-1557, 2012
Resumo:
Objectives: The aim of this study was to evaluate the variation in removal torque of implant prosthetic abutment screws after successive tightening and loosening cycles, in addition to evaluating the influence of the hexagon at the abutment base on screw removal torque. Material and methods: Twenty hexagonal abutments were tightened to 20 regular external hex implants with a titanium alloy screw, with an insertion torque of 32 N cm, measured with a digital torque gauge. The implant/abutment/screw assemblies were divided into two groups: ( 1) abutments without hexagon at the base and ( 2) abutments with a hexagon at the base. Each assembly received a provisional restoration and was submitted to mechanical loading cycles. After this, the screws were removed and the removal torque was measured. This sequence was repeated 10 times, then the screw was replaced by a new one, and another cycle was performed. Linear regression analysis was performed. Results: Removal torque values tended to decrease as the number of insertion/removal cycles increased, for both groups. Comparisons of the slopes and the intercepts between groups showed no statistical difference. There was no significant difference between the mean values of last five cycles and the 11th cycle. Within the limitations of this in vitro study, it was concluded that ( 1) repeated insertion/removal cycles promoted gradual reduction in removal torque of screws, ( 2) replacing the screw with a new one after 10 cycles did not increase resistance to loosening, and ( 3) removal of the hexagon from the abutment base had no effect on the removal torque of the screws.
Resumo:
Dentine hypersensitivity (DH) is a painful condition and is a clinical challenge due to the different treatment strategies available. High-intensity lasers have been studied as a possible option. The aim of this randomized, controlled, double-blind clinical study was to evaluate the effects of Er:YAG and Er,Cr:YSGG lasers on DH. The study group comprised 28 subjects who met the inclusion criteria. A visual analogue scale was used to quantify sensitivity before treatment as baseline, immediately before and immediately after treatment, and 1 week and 1 month after treatment. Teeth were assigned to four groups: group 1 control (no treatment), group 2 Er:YAG laser treatment (2 Hz/32.4 mJ/5.9 J/cm(2)), group 3 Er,Cr:YSGG laser treatment (0.25 W/4.4 J/cm(2)), and group 4 Er,Cr:YSGG laser treatment (0.50 W/ 8.9 J/cm(2)). Data were collected and submitted to statistical analysis for both evaporative (air) and mechanical (probe) stimulation. For both the air and probe stimulation no differences were observed between the pretreatment sensitivities. With the evaporative stimulus, the pain level immediately after treatment was reduced; however, after this the values remained stable. Irradiation with the Er:YAG laser was associated with the lowest level of pain. With the mechanical stimulus, group 4 showed the most pronounced decrease in pain immediately after treatment; however, by the end of the study, pain levels had increased. Groups 1, 2 and 3 showed a reduction in pain that was significantly different from that in group 4 after the 4 weeks of clinical follow up. Based on the results and within the limits of this study, it can be concluded that none of the laser treatments studied was capable of completely eliminating pain, but the Er:YAG and Er,Cr:YSGG lasers are suitable for the treatment of DH.
Resumo:
Objectives. This study recorded and evaluated the intra-and inter-group agreement degree by different examiners for the classification of lower third molars according to both the Winter's and Pell & Gregory's systems. Study Design. An observational and cross-sectional study was realized with forty lower third molars analyzed from twenty digital panoramic radiographs. Four examiner groups (undergraduates, maxillofacial surgeons, oral radiologists and clinical dentists) from Aracaju, Sergipe, Brazil, classified them in relation to angulation, class and position. The variance test (ANOVA) was applied in the examiner findings with significance level of p<0.05 and confidence intervals of 95%. Results. Intra- and inter-group agreement was observed in Winter's classification system among all examiners. Pell & Gregory's classification system showed an average intra-group agreement and a statistical significant difference to position variable in inter-group analysis with greater disagreement to the clinical dentists group (p<0.05). Conclusions. High reproducibility was associated to Winter's classification, whereas the system proposed by Pell & Gregory did not demonstrate appropriate levels of reliability.
Resumo:
Objective: The flexural strength and the elastic modulus of acrylic resins, Dencor, Duralay and Trim Plus II, were evaluated with and without the addition of silanised glass fibre. Materials and methods: To evaluate the flexural strength and elastic modulus, 60 test specimens were fabricated with the addition of 10% ground silanised glass fibres for the experimental group, and 60 without the incorporation of fibres, for the control group, with 20 test specimens being made of each commercial brand of resin (Dencor, Duralay and Trim Plus II) for the control group and experimental group. After the test specimens had been completed, the flexural strength and elastic modulus tests were performed in a universal testing device, using the three-point bending test. For the specimens without fibres the One-Way Analysis of Variance and the complementary Tukey test were used, and for those with fibres it was not normal, so that the non-parametric Mann-Whitney test was applied. Results: For the flexural strength test, there was no statistical difference (p > 0.05) between each commercial brand of resin without fibres [Duralay 84.32(+/- 8.54), Trim plus 85.39(+/- 6.74), Dencor 96.70(+/- 6.52)] and with fibres (Duralay 87.18, Trim plus 88.33, Dencor 98.10). However, for the elastic modulus, there was statistical difference (p > 0.01) between each commercial brand of resin without fibres [Duralay 2380.64 (+/- 168.60), Trim plus 2740.37(+/- 311.74), Dencor 2595.42(+/- 261.22)] and with fibres (Duralay 3750.42, Trim plus 3188.80, Dencor 3400.75). Conclusion: The result showed that the incorporation of fibre did not interfere in the flexural strength values, but it increased the values for the elastic modulus.
Resumo:
Complexity in time series is an intriguing feature of living dynamical systems, with potential use for identification of system state. Although various methods have been proposed for measuring physiologic complexity, uncorrelated time series are often assigned high values of complexity, errouneously classifying them as a complex physiological signals. Here, we propose and discuss a method for complex system analysis based on generalized statistical formalism and surrogate time series. Sample entropy (SampEn) was rewritten inspired in Tsallis generalized entropy, as function of q parameter (qSampEn). qSDiff curves were calculated, which consist of differences between original and surrogate series qSampEn. We evaluated qSDiff for 125 real heart rate variability (HRV) dynamics, divided into groups of 70 healthy, 44 congestive heart failure (CHF), and 11 atrial fibrillation (AF) subjects, and for simulated series of stochastic and chaotic process. The evaluations showed that, for nonperiodic signals, qSDiff curves have a maximum point (qSDiff(max)) for q not equal 1. Values of q where the maximum point occurs and where qSDiff is zero were also evaluated. Only qSDiff(max) values were capable of distinguish HRV groups (p-values 5.10 x 10(-3); 1.11 x 10(-7), and 5.50 x 10(-7) for healthy vs. CHF, healthy vs. AF, and CHF vs. AF, respectively), consistently with the concept of physiologic complexity, and suggests a potential use for chaotic system analysis. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4758815]
Resumo:
Objectives: This study compared the biomechanical fixation and bone-to-implant contact (BIC) of implants with different surfaces treatment (experimental resorbable blasting media-processed nanometer roughness scale surface, and control dual acid-etched) in a dog model. Material and methods: Surface characterization was made in six implants by means of scanning electron microscopic imaging, atomic force microscopy to evaluate roughness parameters, and X-ray photoelectron spectroscopy (XPS) for chemical assessment. The animal model comprised the bilateral placement of control (n = 24) and experimental surface (n = 24) implants along the proximal tibiae of six mongrel dogs, which remained in place for 2 or 4 weeks. Half of the specimens were biomechanically tested (torque), and the other half was subjected to histomorphologic/ morphometric evaluation. BIC and resistance to failure measures were each evaluated as a function of time and surface treatment in a mixed model ANOVA. Results: Surface texturing was significantly higher for the experimental compared with the control surface. The survey XPS spectra detected O, C, Al, and Ti at the control group, and Ca (similar to 0.2-0.9%) and P (similar to 1.7-4.1%) besides O, C, Al, and Ti at experimental surfaces. While no statistical difference in BIC was found between experimental and control surfaces or between 2 and 4 weeks in vivo, both longer time and use of experimental surface significantly increased resistance to failure. Conclusions: The experimental surface resulted in enhanced biomechanical fixation but comparable BIC relative to control, suggesting higher bone mechanical properties around the experimental implants.