33 resultados para Six point evaluation

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This study aimed to compare the micro-tensile bond strength of methacrylate resin systems to a silorane-based restorative system on dentin after 24 hours and six months water storage. Material and Methods: The restorative systems Adper Single Bond 2/Filtek Z350 (ASB), Clearfil SE Bond/Z350 (CF), Adper SE Plus/Z350 (ASEP) and P90 Adhesive System/Filtek P90 (P90) were applied on flat dentin surfaces of 20 third molars (n=5). The restored teeth were sectioned perpendicularly to the bonding interface to obtain sticks (0.8 mm2) to be tested after 24 hours (24 h) and 6 months (6 m) of water storage, in a universal testing machine at 0.5 mm/min. The data was analyzed via two-way Analysis of Variance/Bonferroni post hoc tests at 5% global significance. Results: Overall outcomes did not indicate a statistical difference for the resin systems (p=0.26) nor time (p=0.62). No interaction between material × time was detected (p=0.28). Mean standard-deviation in MPa at 24 h and 6 m were: ASB 31.38 (4.53) and 30.06 (1.95), CF 34.26 (3.47) and 32.75 (4.18), ASEP 29.54 (4.14) and 33.47 (2.47), P90 30.27 (2.03) and 31.34 (2.19). Conclusions: The silorane-based system showed a similar performance to methacrylate-based materials on dentin. All systems were stable in terms of bond strength up to 6 month of water storage.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A low-cost circuit was developed for stable and efficient maximum power point (MPP) tracking in autonomous photo voltaic-motor systems with variable-frequency drives (VFDs). The circuit is made of two resistors, two capacitors, and two Zener diodes. Its input is the photovoltaic (PV) array voltage and its output feeds the proportional-integral-derivative (PID) controller usually integrated into, the drive. The steady-state frequency-voltage oscillations induced by the circuit were treated in a simplified mathematical model, which was validated by widely characterizing a PV-powered centrifugal pump. General procedures for circuit and controller tuning were recommended based on model equations. The tracking circuit presented here is widely applicable to PV-motor system with VFDs, offering an. efficient open-access technology of unique simplicity. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A specific manufacturing process to obtain continuous glass fiber-reinforced RIFE laminates was studied and some of their mechanical properties were evaluated. Young's modulus and maximum strength were measured by three-point bending test and tensile test using the Digital Image Correlation (DIC) technique. Adhesion tests, thermal analysis and microscopy were used to evaluate the fiber-matrix adhesion, which is very dependent on the sintering time. The composite material obtained had a Young's modulus of 14.2 GPa and ultimate strength of 165 MPa, which corresponds to approximately 24 times the modulus and six times the ultimate strength of pure RIFE. These results show that the RIFE composite, manufactured under specific conditions, has great potential to provide structural parts with a performance suitable for application in structural components. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Most of the antiretroviral (ARV) studies in Brazil have been reported in treatment-experienced and naive patients rather than in the setting of treatment interruption (TI). In this study, we analysed reasons given for TI and resistance mutations occurring in 150 HIV-1-infected patients who underwent TI. Of the patients analysed, 110 (73.3%) experienced TI following medical advice, while the remaining patients stopped antiretroviral therapy (ART) of their own accord. The main justifications for TI were: ARV-related toxicities (38.7%), good laboratory parameters (30%) and poor adherence (20%). DNA sequencing of the partial pol gene was successful in 137 (91.3%) patients, of whom 38 (27.7%) presented mutations conferring ARV resistance. A higher viral load prior to TI correlated with drug resistance (P < 0.05). Our results demonstrate that there are diverse rationales for TI and that detection of resistant strains during TI most likely indicates a fitter virus than the wild type. High viral loads coupled with unprotected sex in this group could increase the likelihood of transmission of drug-resistant virus. Thus, treating physicians should be alerted to this problem when the use of ARVs is interrupted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. To evaluate the effect of an experimental gel containing Euclea natalensis extract on dentin permeability. Methods. Thirty-six dentin discs, 1-mm-thick. The discs were prepared from the coronal dentin of extracted human third molars that were divided into 3 groups (n = 10). The dentin discs in each group were treated with the groups following experimental materials: (FG): 1.23% fluoride gel, pH 4.1; (EG): Euclea natalensis extract gel, pH 4.1; (CG): control gel, pH 4.1. The gels were applied to the occlusal slide of the dentin under the following conditions: after 37% phosphoric acid and before 6% citric acid. The hydraulic conductance (HC) of each condition was determined four times using a fluid flow apparatus (Flodec). The data were analyzed using Two-way ANOVA and Tukey's test (P < 0.05). Results. The greatest mean reduction in HC was produced in group EG dentin discs (61.2%; P < 0.05). Even after acid challenge with 6% citric acid the great reduction occurred in group EG (66.0%; P < 0.05) than other groups (CG-77.1%, FG-90.8%). Conclusion. E. natalensis gel not only reduced dentin permeability, but also resisted posttreatment citric acid challenge without changing its permeability. Further research has to confirm this promising result in the clinical situation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aims of this in vivo study were to compare the effectiveness and color stability of at-home and in-office bleaching techniques and to evaluate whether the use of light sources can alter bleaching results. According to preestablished criteria, 40 patients were selected and randomly divided into four groups according to bleaching treatment: (1) at-home bleaching with 10% carbamide peroxide, (2) in-office bleaching with 35% hydrogen peroxide (HP) without a light source, (3) in-office bleaching with 35% HP with quartz-tungsten-halogen light, and (4) in-office bleaching with 35% HP with a light-emitting diode/laser. Tooth shade was evaluated using the VITA Classical Shade Guide before bleaching as well as after the first and third weeks of bleaching. Tooth shade was evaluated again using the same guide 1 and 6 months after the completion of treatment. The shade guide was arranged to yield scores that were used for statistical comparison. Statistical analysis using the Kruskal-Wallis test showed no significant differences among the groups for any time point (P > .01). There was no color rebound in any of the groups. The bleaching techniques tested were equally effective. Light sources are unnecessary to bleach teeth. (Int J Periodontics Restorative Dent 2012;32:303-309.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Actinic cheilitis, a common disease caused by chronic solar exposure and tobacco use, is considered a premalignant lesion with potential to develop into squamous cell carcinoma. Some of the available treatments are invasive, have unaesthetic results and require multiple sessions. OBJECTIVE: To assess the efficacy of a therapy and its cosmetic results. METHODS: In this uncontrolled clinical trial a single photodynamic therapy (PDT) session using 16% methyl-aminolevulinate was performed on actinic cheilitis of the lower lip. A standardized questionnaire was applied in order to assess the clinical improvement from the patients' point of view and the satisfaction with the treatment. Anatomopathological evaluation was performed before the treatment and two months afterwards. RESULTS: The sample was composed of 19 patients (10 males and 9 females), phototypes I to III, with average age of 62 years. Main adverse effects were: sudden pain, scabs, herpes flare-up, and edema. The average score of pain during the procedure was 5,8+2,9. At the final assessment the patients reported improvement of 80% and satisfaction of 85% (p<0.01). Anatomopathological analysis showed a significant decrease of dysplasia (p=0.03) in spite of its presence in 84% of cases. There was no significant correlation between the level of dysplasia with either the subjective impression of clinical improvement (p=0.82) or with the patients' final satisfaction (p=0.96). CONCLUSION: PDT is effective in the treatment of actinic cheilitis, but it is associated with a significant level of pain. Due to the persistence of dysplasia, more research needs to be done in order to define the ideal number of sessions for the effective treatment of these lesions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the anatomical and functional renal alterations and the association with post-traumatic arterial hypertension. Methods: The studied population included patients who sustained high grades renal injury (grades III to V) successfully non-operative management after staging by computed tomography over a 16-year period. Beyond the review of medical records, these patients were invited to the following protocol: clinical and laboratory evaluation, abdominal computed tomography, magnetic resonance angiography, DMSA renal scintigraphy, and ambulatory blood pressure monitoring. The hypertensive patients also were submitted to dynamic renal scintigraphy (Tc-99m EC), using captopril stimulation to verify renal vascular etiology. Results: Of the 31 patients, there were thirteen grade III, sixteen grade IV (nine lacerations, and seven vascular lesions), and two grade V injuries. All the patients were asymptomatic and an average follow up post-injury of 6.4 years. None had abnormal BUN or seric creatinine. The percentage of renal volume reduction correlates with the severity as defined by OIS. There was no evidence of renal artery stenosis in Magnetic Resonance angiography (MRA). DMSA scanning demonstrated a decline in percentage of total renal function corresponding to injury severity (42.2 +/- 5.5% for grade III, 35.3 +/- 12.8% for grade IV, 13.5 +/- 19.1 for grade V). Six patients (19.4%) had severe compromised function (< 30%). There was statistically significant difference in the decrease in renal function between parenchymal and vascular causes for grade IV injuries (p < 0.001). The 24-hour ambulatory blood pressure monitoring detected nine patients (29%) with post-traumatic hypertension. All the patients were male, mean 35.6 years, 77.8 % had a familial history of arterial hypertension, 66.7% had grade III renal injury, and average post-injury time was 7.8 years. Seven patients had negative captopril renography. Conclusions: Late results of renal function after conservative treatment of high grades renal injuries are favorable, except for patients with grades IV with vascular injuries and grade V renal injuries. Moreover, arterial hypertension does not correlate with the grade of renal injury or reduction of renal function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. The null hypothesis was that mechanical testing systems used to determine polymerization stress (sigma(pol)) would rank a series of composites similarly. Methods. Two series of composites were tested in the following systems: universal testing machine (UTM) using glass rods as bonding substrate, UTM/acrylic rods, "low compliance device", and single cantilever device ("Bioman"). One series had five experimental composites containing BisGMA:TEGDMA in equimolar concentrations and 60, 65, 70, 75 or 80 wt% of filler. The other series had five commercial composites: Filtek Z250 (3M ESPE), Filtek A110 (3M ESPE), Tetric Ceram (Ivoclar), Heliomolar (Ivoclar) and Point 4 (Kerr). Specimen geometry, dimensions and curing conditions were similar in all systems. sigma(pol) was monitored for 10 min. Volumetric shrinkage (VS) was measured in a mercury dilatometer and elastic modulus (E) was determined by three-point bending. Shrinkage rate was used as a measure of reaction kinetics. ANOVA/Tukey test was performed for each variable, separately for each series. Results. For the experimental composites, sigma(pol) decreased with filler content in all systems, following the variation in VS. For commercial materials, sigma(pol) did not vary in the UTM/acrylic system and showed very few similarities in rankings in the others tests system. Also, no clear relationships were observed between sigma(pol) and VS or E. Significance. The testing systems showed a good agreement for the experimental composites, but very few similarities for the commercial composites. Therefore, comparison of polymerization stress results from different devices must be done carefully. (c) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of a photodegradable tape was evaluated on 'Valencia' sweet orange nursery trees budded both on Rangpur lime and Swingle citrumelo in a greenhouse in Bebedouro-SP, Brazil, from September to November 2009. On both rootstocks three wrapping procedures were evaluated: i) conventional polyethylene tape wrapped around the bud eye; ii) photodegradable tape wrapped around the bud eye, and iii) photodegradable tape wrapped around the graft junction without covering the bud eye. The following variables were measured: time spent for wrapping, percentage of bud sprouting, length and stem diameter of the scion shoot, and percentage of commercially valuable nursery trees. The trial was conducted following a randomized complete block design, with six treatments, four replications and 12 trees per plot. The use of photodegradable tape, with or without covering the bud eye, anticipated bud sprouting; despite of the longer time spent with wrapping when the photodegradable tape was used. Plants grafted onto the less vigorous Swingle citrumelo rootstock showed lower bud sprout percentages when the bud eye was covered with the photodegradable tape.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

doi: 10.1111/j.1741-2358.2011.00526.x Biological evaluation of the bone healing process after application of two potentially osteogenic proteins: an animal experimental model Objective: The aim of this work was to analyse qualitatively and quantitatively the newly formed bone after insertion of rhBMP-2 and protein extracted from Hevea brasiliensis (P-1), associated or not with a carrier in critical bone defects created in Wistar rat calvarial bone, using histological and histomorphometrical analyses. Materials and methods: Eighty-four male Wistar rats were used, divided into two groups, according to the period of time until the sacrifice (2 and 6 weeks). Each one of these groups was subdivided into six groups with seven animals each, according to the treatments: (1) 5 mu g of pure rhBMP-2, (2) 5 mu g of rhBMP-2/monoolein gel, (3) pure monoolein gel, (4) 5 mu g of pure P-1, (5) 5 mu g of P-1/monoolein gel and (6) critical bone defect controls. The animals were euthanised and the calvarial bone tissue removed for histological and histomorphometrical analyses. Result and conclusion: The results showed an improvement in the bone healing process using the rhBMP-2 protein, associated or not with a material carrier in relation to the other groups, and this process demonstrated to be time dependent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, an analysis of scientific bibliographic productivity was made using the Faculdade de Filosofia e Ciencias, Universidade Estadual Paulista (FFC-UNESP) as example. It is composed by nine departments which offer altogether nine undergraduate courses: 1) Archival, 2) Library, 3) Speech Therapy, 4) Pedagogy, 5) International Relations, 6) Physiotherapy, 7) Occupational Therapy, 8) Philosophy, 9) Social Sciences and six graduate programs leading to M. S. and Ph.D. degrees. Moreover, when analyzing the different courses of FFC-UNESP, they represent typical academic organization in Brazil and Latin America and could be taken as a model for analyzing other Brazilian research institutions. Using data retrieved from the Lattes Plataform database (Curriculum Lattes) we have quantitatively the scientific productivity percentage of professors at UNESP. We observed that bibliometric evaluations using the Curriculum Lattes (CL) showed that the professors published papers in journal are not indexed by ISI and SCOPUS. This analysis was made using: 1) the total number of papers (indexed in Curriculum Lattes database), 2) the number of papers indexed by Thomson ISI Web of Science database and SCOPUS database, and 3) the Hirsch (h-index) by ISI and SCOPUS. Bibliometric evaluations of departments showed a better performance of Political Science and Economics Department when compared to others departments, in relation total number of papers (indexed in Curriculum Lattes database). We also analyzed the academic advisory (Master's Thesis and Ph. D. Thesis) by nine departments of FFC/UNESP. The Administration and School Supervision Department presented a higher academic advisory (concluded and current) when compared to the others departments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The flexural strength and the elastic modulus of acrylic resins, Dencor, Duralay and Trim Plus II, were evaluated with and without the addition of silanised glass fibre. Materials and methods: To evaluate the flexural strength and elastic modulus, 60 test specimens were fabricated with the addition of 10% ground silanised glass fibres for the experimental group, and 60 without the incorporation of fibres, for the control group, with 20 test specimens being made of each commercial brand of resin (Dencor, Duralay and Trim Plus II) for the control group and experimental group. After the test specimens had been completed, the flexural strength and elastic modulus tests were performed in a universal testing device, using the three-point bending test. For the specimens without fibres the One-Way Analysis of Variance and the complementary Tukey test were used, and for those with fibres it was not normal, so that the non-parametric Mann-Whitney test was applied. Results: For the flexural strength test, there was no statistical difference (p > 0.05) between each commercial brand of resin without fibres [Duralay 84.32(+/- 8.54), Trim plus 85.39(+/- 6.74), Dencor 96.70(+/- 6.52)] and with fibres (Duralay 87.18, Trim plus 88.33, Dencor 98.10). However, for the elastic modulus, there was statistical difference (p > 0.01) between each commercial brand of resin without fibres [Duralay 2380.64 (+/- 168.60), Trim plus 2740.37(+/- 311.74), Dencor 2595.42(+/- 261.22)] and with fibres (Duralay 3750.42, Trim plus 3188.80, Dencor 3400.75). Conclusion: The result showed that the incorporation of fibre did not interfere in the flexural strength values, but it increased the values for the elastic modulus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Complexity in time series is an intriguing feature of living dynamical systems, with potential use for identification of system state. Although various methods have been proposed for measuring physiologic complexity, uncorrelated time series are often assigned high values of complexity, errouneously classifying them as a complex physiological signals. Here, we propose and discuss a method for complex system analysis based on generalized statistical formalism and surrogate time series. Sample entropy (SampEn) was rewritten inspired in Tsallis generalized entropy, as function of q parameter (qSampEn). qSDiff curves were calculated, which consist of differences between original and surrogate series qSampEn. We evaluated qSDiff for 125 real heart rate variability (HRV) dynamics, divided into groups of 70 healthy, 44 congestive heart failure (CHF), and 11 atrial fibrillation (AF) subjects, and for simulated series of stochastic and chaotic process. The evaluations showed that, for nonperiodic signals, qSDiff curves have a maximum point (qSDiff(max)) for q not equal 1. Values of q where the maximum point occurs and where qSDiff is zero were also evaluated. Only qSDiff(max) values were capable of distinguish HRV groups (p-values 5.10 x 10(-3); 1.11 x 10(-7), and 5.50 x 10(-7) for healthy vs. CHF, healthy vs. AF, and CHF vs. AF, respectively), consistently with the concept of physiologic complexity, and suggests a potential use for chaotic system analysis. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4758815]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: This study compared the biomechanical fixation and bone-to-implant contact (BIC) of implants with different surfaces treatment (experimental resorbable blasting media-processed nanometer roughness scale surface, and control dual acid-etched) in a dog model. Material and methods: Surface characterization was made in six implants by means of scanning electron microscopic imaging, atomic force microscopy to evaluate roughness parameters, and X-ray photoelectron spectroscopy (XPS) for chemical assessment. The animal model comprised the bilateral placement of control (n = 24) and experimental surface (n = 24) implants along the proximal tibiae of six mongrel dogs, which remained in place for 2 or 4 weeks. Half of the specimens were biomechanically tested (torque), and the other half was subjected to histomorphologic/ morphometric evaluation. BIC and resistance to failure measures were each evaluated as a function of time and surface treatment in a mixed model ANOVA. Results: Surface texturing was significantly higher for the experimental compared with the control surface. The survey XPS spectra detected O, C, Al, and Ti at the control group, and Ca (similar to 0.2-0.9%) and P (similar to 1.7-4.1%) besides O, C, Al, and Ti at experimental surfaces. While no statistical difference in BIC was found between experimental and control surfaces or between 2 and 4 weeks in vivo, both longer time and use of experimental surface significantly increased resistance to failure. Conclusions: The experimental surface resulted in enhanced biomechanical fixation but comparable BIC relative to control, suggesting higher bone mechanical properties around the experimental implants.