2 resultados para Sistema Español de Ciencia, Tecnología e Innovación
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
This paper presents further results from our spectroscopic study of the globular cluster (GC) system of the group elliptical NGC 3923. From observations made with the GMOS instrument on the Gemini South Telescope, an additional 50 GC and ultra-compact dwarf (UCD) candidates have been spectroscopically confirmed as members of the NGC 3923 system. When the recessional velocities of these GCs are combined with the 29 GC velocities reported previously, a total sample of 79 GC/UCD velocities is produced. This sample extends to over 6 arcmin (>6 R-e similar to 30 kpc) from the centre of NGC 3923 and is used to study the dynamics of the GC system and the dark matter content of NGC 3923. It is found that the GC system of NGC 3923 displays no appreciable rotation, and that the projected velocity dispersion is constant with radius within the uncertainties. The velocity dispersion profiles of the integrated light and GC system of NGC 3923 are indistinguishable over the region in which they overlap. We find some evidence that the diffuse light and GCs of NGC 3923 have radially biased orbits within similar to 130 arcsec. The application of axisymmetric orbit-based models to the GC and integrated light velocity dispersion profiles demonstrates that a significant increase in the mass-to-light ratio (from M/L-V = 8 to 26) at large galactocentric radii is required to explain this observation. We therefore confirm the presence of a dark matter halo in NGC 3923. We find that dark matter comprises 17.5(-4.5)(+7.3) per cent of the mass within 1 R-e, 41.2(-10.6)(+18.2) per cent within 2 R-e and 75.6(-16.8)(+15.4) per cent within the radius of our last kinematic tracer at 6.9 R-e. The total dynamical mass within this radius is found to be 1.5(-0.25)(+0.4) x 10(12) M-circle dot. In common with other studies of large ellipticals, we find that our derived dynamical mass profile is consistently higher than that derived by X-ray observations, by a factor of around 2.
Resumo:
OBJETIVO: identificar, entre os cursos de Mestrado Acadêmico dos programas de pós-graduação em enfermagem brasileiros, analisados por ocasião da avaliação trienal (2007-2009) da Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, a carga horária informada pelos programas para a formação de mestre. MÉTODO: trata-se de estudo descritivo, quantitativo, documental, com dados coletados em julho de 2010, mediante consulta aos relatórios da citada Coordenação, no quesito "Propostas dos Programas", dos Cadernos de Indicadores, disponíveis na web. RESULTADOS: foram encontradas discrepâncias entre as cargas horárias dos 32 cursos de Mestrado Acadêmico das diversas regiões do Brasil, sendo que a menor carga horária foi de 315 horas e a maior de 1.530 horas. CONCLUSÕES: há necessidade de maior discussão acerca da carga horária necessária à formação das competências e habilidades para o perfil desejado do egresso. O estudo propicia avanços no conhecimento da enfermagem, pois não foram identificadas investigações pregressas que tratem de tal tema. Espera-se que os cursos de Mestrado Acadêmico de enfermagem percebam-se nesse processo e revejam suas decisões pedagógicas, à luz dos novos modelos de formação/capacitação dos profissionais de enfermagem, centrados na ciência, tecnologia e inovação na área.