8 resultados para Single-Blind Method

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to evaluate the erosive potential of orange juice modified with food-approved additives: 0.4 g/l of calcium (Ca) from calcium lactate pentahydrate, 0.2 g/l of linear sodium polyphosphate (LPP) or their combination (Ca+LPP) were added to a commercially available orange juice (negative control, C-). A commercially available calcium-modified orange juice (1.6 g/l of calcium) was the positive control (C+). These juices were tested using a short-term erosion in situ model, consisting of a five-phase, single-blind crossover clinical trial involving 10 subjects. In each phase, subjects inserted custom-made palatal appliances containing 8 bovine enamel specimens in the mouth and performed erosive challenges for a total of 0 (control), 10, 20, and 30 min. Two specimens were randomly removed from the appliances after each challenge period. Enamel surface microhardness was measured before and after the clinical phase and the percentage of surface microhardness change (%SMC) was determined. Before the procedures, in each phase, the subjects performed a taste test, where the juice assigned to that phase was blindly compared to C-. Overall, C+ showed the lowest %SMC, being the least erosive solution (p < 0.05), followed by Ca+LPP and Ca, which did not differ from each other (p > 0.05). LPP and C- were the most erosive solutions (p <0.05). Taste differences were higher for C+ (5/10 subjects) and Ca (4/10 subjects), but detectable in all groups, including C- (2/10 subjects). Calcium reduced the erosive potential of the orange juice, while no protection was observed for LPP. Copyright (C) 2012 S. Karger AG, Basel

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Trata-se de estudo clínico randomizado, simples cego, com o objetivo de avaliar a eficácia da auriculoterapia verdadeira e placebo na diminuição dos níveis de estresse em alunos de nível médio, da Escola de Enfermagem do Hospital Beneficência Portuguesa. Setenta e um estudantes com escores médio, alto e altíssimo, pela Lista de Sintomas de Estresse de Vasconcellos, foram divididos em 3 grupos: controle (25), auriculoterapia (24) e placebo/Sham (22). Foram avaliados, no início, com 8, 12 sessões e follow-up (15 dias) e receberam os pontos Shen Men, tronco cerebral (auriculoterapia) e punho e ouvido externo (placebo/Sham). Na análise de variância (Anova) constataram-se diferenças estatísticas significativas entre os grupos controle/auriculoterapia a partir de 8 sessões, mantendo-se após a terceira e a quarta avaliação (p=0,000) e entre controle/placebo (p<0,05), nas três avaliações. Concluiu-se que a auriculoterapia verdadeira obteve melhores respostas (45,39%) do que o placebo (34,18%) na redução do estresse, mas recomendam-se mais estudos para reavaliação de pontos Sham para estresse. ClinicalTrials.gov Identifier: NCT01420848.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives To investigate the effect of Nintendo Wii (TM)-based motor cognitive training versus balance exercise therapy on activities of daily living in patients with Parkinson's disease. Design Parallel, prospective, single-blind, randomised clinical trial. Setting Brazilian Parkinson Association. Participants Thirty-two patients with Parkinson's disease (Hoehn and Yahr stages 1 and 2). Interventions Fourteen training sessions consisting of 30 minutes of stretching, strengthening and axial mobility exercises, plus 30 minutes of balance training. The control group performed balance exercises without feedback or cognitive stimulation, and the experimental group performed 10 Wii Fit (TM) games. Main outcome measure Section II of the Unified Parkinson's Disease Rating Scale (UPDRS-II). Randomisation Participants were randomised into a control group (n = 16) and an experimental group (n = 16) through blinded drawing of names. Statistical analysis Repeated-measures analysis of variance (RM-ANOVA). Results Both groups showed improvement in the UPDRS-II with assessment effect (RM-ANOVA P < 0.001, observed power = 0.999). There was no difference between the control group and the experimental group before training {8.9 [standard deviation (SD) 2.9] vs 10.1 (SD 3.8)}, after training [7.6 (SD 2.9) vs 8.1 (SD 3.5)] or 60 days after training [8.1 (SD 3.2) vs 8.3 (SD 3.6)]. The mean difference of the whole group between before training and after training was -0.9 (SD 2.3, 95% confidence interval -1.7 to -0.6). Conclusion Patients with Parkinson's disease showed improved performance in activities of daily living after 14 sessions of balance training, with no additional advantages associated with the Wii-based motor and cognitive training. Registered on http://www.clinicaltrials.gov (identifier: NCT01580787). (C) 2012 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE To assess the efficacy of group psychotherapy (GTP) and/or sildenafil for psychogenic erectile dysfunction (ED). PATIENTS AND METHODS A randomized controlled single-blind trial was performed at the Institute of Psychiatry of the Medical School of at Universidade de Sao Paulo, Sao Paulo, Brazil. In all, 30 men with mild and moderate psychogenic ED were randomized to receive for 6 months: GPT plus 50 mg sildenafil on-demand, or 50 mg sildenafil on-demand exclusively, or GPT exclusively. Changes in score from baseline for three questions of the Erectile Dysfunction Inventory of Treatment Satisfaction (EDITS) were evaluated at endpoint and after 3-months follow-up. RESULTS Satisfaction with the treatment, confidence and 'naturalness' increased in the GPT plus sildenafil and GPT exclusively groups (P = 0.001) from baseline to endpoint. The treatment-by-time comparison was not significant at endpoint vs the 3-month follow-up, in the three groups. There was no difference in the sildenafil group in the three study periods (P > 0.05) CONCLUSION Men with mild and moderate psychogenic ED had higher treatment satisfaction, confidence and naturalness in engaging in sexual activity when receiving GPT plus sildenafil or GP exclusively, when compared with sildenafil exclusively, as assessed by these three EDITS questions after 6-months treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: Cardiopulmonary bypass is associated with ischemia-reperfusion injury to multiple organs. We aimed to evaluate whether remote ischemic preconditioning performed the day before surgery for congenital heart disease with cardiopulmonary bypass attenuates the postoperative inflammatory response and myocardial dysfunction. Methods: This was a prospective, randomized, single-blind, controlled trial. Children allocated to remote ischemic preconditioning underwent 4 periods of 5 minutes of lower limb ischemia by a blood pressure cuff intercalated with 5 minutes of reperfusion. Blood samples were collected 4, 12, 24, and 48 hours after cardiopulmonary bypass to evaluate nuclear factor kappa B activation in leukocytes by quantification of mRNA of I kappa B alpha by real-time quantitative polymerase chain reaction and for interleukin-8 and 10 plasma concentration measurements by enzyme-linked immunosorbent assay. Myocardial dysfunction was assessed by N-terminal pro-B-type natriuretic peptide and cardiac troponin I plasma concentrations, measured by chemiluminescence, and clinical parameters of low cardiac output syndrome. Results: Twelve children were allocated to remote ischemic preconditioning, and 10 children were allocated to the control group. Demographic data and Risk Adjustment for Congenital Heart Surgery 1 classification were comparable in both groups. Remote ischemic preconditioning group had lower postoperative values of N-terminal pro-B-type natriuretic peptide, but cardiac troponin I levels were not significantly different between groups. Interleukin-8 and 10 concentrations and I kappa B alpha gene expression were similar in both groups. Postoperative morbidity was similar in both groups; there were no postoperative deaths in either group. Conclusions: Late remote ischemic preconditioning did not provide clinically relevant cardioprotection to children undergoing cardiopulmonary bypass. (J Thorac Cardiovasc Surg 2012;144:178-83)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives. To purpose a method for predicting the shrinkage stress development in the adhesive layer of resin-composite cylinders that shrink bonded to a single flat surface, by measuring the deflection of a glass coverslip caused by the shrinkage of the bonded cylinders. The correlation between the volume of the bonded resin-composite and the stress-peak was also investigated. Methods. A glass coverslip deflection caused by the shrinkage of a bonded resin-composite cylinder (diameter: d = 8 mm, 4 mm, or 2 mm, height: h = 4 mm, 2 mm, 1 mm, or 0.5 mm) was measured, and the same set-up was simulated by finite element analysis (3D-FEA). Stresses generated in the adhesive layer were plotted versus two geometric variables of the resin-composite cylinder (C-Factor and volume) to verify the existence of correlations between them and stresses. Results. The FEA models were validated. A significant correlation (p < 0.01, Pearson's test) between the stress-peak and the coverslip deflection when the resin-composites were grouped by diameter was found for diameters of 2 and 4 mm. The stress-peak of the whole set of data showed a logarithmic correlation with the bonded resin-composite volume (p < 0.001, Pearson's test), but did not correlate with the C-Factor. Significance. The described method should be considered for standardizing the stress generated by the shrinkage of resin-composite blocks bonded to a single flat surface. (C) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, a novel method for power quality signal decomposition is proposed based on Independent Component Analysis (ICA). This method aims to decompose the power system signal (voltage or current) into components that can provide more specific information about the different disturbances which are occurring simultaneously during a multiple disturbance situation. The ICA is originally a multichannel technique. However, the method proposes its use to blindly separate out disturbances existing in a single measured signal (single channel). Therefore, a preprocessing step for the ICA is proposed using a filter bank. The proposed method was applied to synthetic data, simulated data, as well as actual power system signals, showing a very good performance. A comparison with the decomposition provided by the Discrete Wavelet Transform shows that the proposed method presented better decoupling for the analyzed data. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aims and objectives. To evaluate the effectiveness of a low-level laser therapy for pain relief in the perineum following episiotomy during childbirth. Background. Laser irradiation is a painless and non-invasive therapy for perineal pain treatment and its effects have been investigated in several studies, with no clear conclusion on its effectiveness. Design. A double-blind randomised controlled clinical trial. Method. One hundred and fourteen women who underwent right mediolateral episiotomies during vaginal birth in an in-hospital birthing centre in Sao Paulo, Brazil and reported pain =3 on a numeric scale (010) were randomised into three groups of 38 women each: two experimental groups (treated with red and infrared laser) and a control group. The experimental groups were treated with laser applied at three points directly on the episiotomy after suturing in a single session between 656 hours postpartum. We used a diode laser with wavelengths of 660 nm (red laser) and 780 nm (infrared laser). The control group participants underwent all laser procedures, excluding the emission of irradiation. The participants and the pain scores evaluator were blinded to the type of intervention. The perineal pain scores were assessed at three time points: before, immediately after and 30 minutes after low-level laser therapy. Results. The comparison of perineal pain between the three groups showed no significant differences in the three evaluations (p = 0.445), indicating that the results obtained in the groups treated with low-level laser therapy were equivalent to the control group. Conclusions. Low-level laser therapy did not decrease the intensity of perineal pain reported by women who underwent right mediolateral episiotomy. Relevance to clinical practice. The effect of laser in perineal pain relief was not demonstrated in this study. The dosage may not have been sufficient to provide relief from perineal pain after episiotomy during a vaginal birth.