8 resultados para Shunt

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram realizados o estudo morfométrico e o estudo hemodinâmico da veia porta em vinte cães clinicamente normais, de idade igual e inferior a 120 dias e em quatorze cães portadores de shunt portossistêmico, de idades entre 90 e 360 dias. Nos cães do grupo controle, as margens hepáticas apresentaram-se entre 1,50cm e 3,00cm caudalmente à margem costal. Os diâmetros médios da veia porta (VP), veia cava caudal (VCC) e aorta abdominal (AO) obtidas foram respectivamente, 0,38cm, 0,37cm e 0,41cm. As proporções entre os diâmetros médios VP/VCC e VP/AO apresentaram médias de 1,10 e 0,94, respectivamente. As médias das áreas da VP, VCC e AO resultaram respectivamente em 0,12cm2 , 0,11cm2 e 0,14cm2. No estudo hemodinâmico da VP destes animais, utilizando-se o ultrassom Doppler, a velocidade média de fluxo sangüíneo portal (VMFSP) mediu 17,76cm/s. A média de fluxo sangüíneo portal (FSP) resultou em 83,11ml/min/kg. O índice de congestão (IC) apresentou média de 0,006. Para o grupo de cães portadores de shunt portossistêmico, o fígado apresentou redução de seu volume, sendo as margens hepáticas visibilizadas entre 1,00cm e 2,00cm cranialmente à margem costal. No estudo morfométrico, as médias dos diâmetros médios obtidos de VP, VCC e AO resultaram respectivamente em 0,40cm, 0,74cm e 0,56cm. As proporções entre os diâmetros médios VP/VCC e VP/AO resultaram respectivamente em 0,54 e 0,69. As médias das áreas de VP, VCC e AO resultaram respectivamente em 0,14cm2, 0,31cm2 e 0,25cm2. Ao ultrassom Doppler a VMFSP mediu 22,29cm/s e a média do IC da VP obtido foi de 0,006.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a technique to palliate hypoplastic left heart syndrome, with no PDA stenting, but with double polytetrafluoroethylene shunt from pulmonary artery to ascending and descending aorta by combined thoracotomies. A 30-day-old female was operated with this technique. Five months after first operation, the child was submitted to Norwood/Glenn operation. Good hemodinamic recovery and initial clinical evolution was observed. The child was extubated in 8th post operatory day and reentubated in the next day due to pulmonary infection. Despite antibiotic treatment, the child died after systemic infectious complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To study changes in lamina cribrosa position and prelaminar tissue thickness (PTT) after surgical IOP reduction in glaucoma patients. METHODS. Twenty-two patients (mean age, 71.4 years) were imaged with spectral domain optical coherence tomography (SD-OCT; 24 radial B-scans centered on the optic nerve head [ONH]) before trabeculectomy or tube shunt implantation. Follow up images were acquired 1 week, 1 month, 3 months, and 6 months postsurgery. Bruch's membrane opening (BMO), the internal limiting membrane (ILM) and the anterior laminar surface (ALS) were segmented in each radial scan with custom software. Surfaces were fitted to the ILM and ALS with the extracted three-dimesional coordinates. PTT was the distance between the ILM and ALS, perpendicular to a BMO reference plane. Serial postsurgical laminar displacement (LD), relative to the BMO reference plane, and changes in PTT were measured. Positive values indicated anterior LD. RESULTS. Mean (SD) presurgery IOP was 18.1 (6.5) mm Hg, and reduced by 4.7 (5.5), 2.4 (7.7), 7.0 (6.2), and 6.8 (7.5) mm Hg at 1 week, 1 month, 3 months, and 6 months postsurgery, respectively. At the four postsurgery time points, there was significant anterior LD (1.8 [9.5], -1.1 [8.9], 8.8 [20.2], and 17.9 [25.8] mu m) and PTT increase (1.7 [13.3], 2.4 [11.9], 17.4 [13.7], and 13.9 [18.6] mu m). LD was greater in ONHs with larger BMO area (P = 0.01) and deeper ALS (P = 0.04); however, PTT was not associated with any of the tested independent variables. CONCLUSIONS. Both anterior LD and thickening of prelaminar tissue occur after surgical IOP reduction in patients with glaucoma. (Invest Ophthalmol Vis Sci. 2012;53:5819-5826) DOI:10.1167/iovs.12-9924

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the clinical outcomes of multivisceral transplantation (MVT) in the setting of diffuse thrombosis of the portomesenteric venous system. Background: Liver transplantation (LT) in the face of cirrhosis and diffuse portomesenteric thrombosis (PMT) is controversial and contraindicated in many transplant centers. LT using alternative techniques such as portocaval hemitransposition fails to eliminate complications of portal hypertension. MVT replaces the liver and the thrombosed portomesenteric system. Methods: A database of intestinal transplant patients was maintained with prospective analysis of outcomes. The diagnosis of diffuse PMT was established with dual-phase abdominal computed tomography or magnetic resonance imaging with venous reconstruction. Results: Twenty-five patients with grade IV PMT received 25 MVT. Eleven patients underwent simultaneous cadaveric kidney transplantation. Biopsy-proven acute cellular rejection was noted in 5 recipients, which was treated successfully. With a median follow-up of 2.8 years, patient and graft survival were 80%, 72%, and 72% at 1, 3, and 5 years, respectively. To date, all survivors have good graft function without any signs of residual/recurrent features of portal hypertension. Conclusions: MVT can be considered as an option for the treatment of patients with diffuse PMT. MVT is the only procedure that completely reverses portal hypertension and addresses the primary disease while achieving superior survival results in comparison to the alternative options.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients with hydrocephalus and risk factors for overdrainage may be submitted to ventricular shunt (VS) implant with antisiphon device. The objective of this study was to prospectively evaluate for two years the clinical and tomographic results of the implant of fixed-pressure valves with antisiphon device SPHERA (R) in 35 adult patients, with hydrocephalus and risk factors for overdrainage. Of these, 3 had congenital hydrocephalus in adult patients with very dilated ventricles (Evans index >50%), 3 had symptomatic overdrainage after previous VS implant (subdural hematoma, hygroma or slit ventricle syndrome), 1 had previous chronic subdural hematoma, 15 had normal pressure hydrocephalus with final lumbar pressure <5 cm H2O after tap test (40 mL), 6 had pseudotumor cerebri, and 7 had hydrocephalus due to other causes. Clinical improvement was observed and sustained in 94.3% of the patients during the two-year period with no computed tomography (CT) evidence of hypo or overdrainage, and no immediate early or late significant complications.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients with hydrocephalus and risk factors for overdrainage may be submitted to ventricular shunt (VS) implant with antisiphon device. The objective of this study was to prospectively evaluate for two years the clinical and tomographic results of the implant of fixed-pressure valves with antisiphon device SPHERA® in 35 adult patients, with hydrocephalus and risk factors for overdrainage. Of these, 3 had congenital hydrocephalus in adult patients with very dilated ventricles (Evans index >50%), 3 had symptomatic overdrainage after previous VS implant (subdural hematoma, hygroma or slit ventricle syndrome), 1 had previous chronic subdural hematoma, 15 had normal pressure hydrocephalus with final lumbar pressure <5 cm H2O after tap test (40 mL), 6 had pseudotumor cerebri, and 7 had hydrocephalus due to other causes. Clinical improvement was observed and sustained in 94.3% of the patients during the two-year period with no computed tomography (CT) evidence of hypo or overdrainage, and no immediate early or late significant complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of piezoelectric materials for the development of electromechanical devices for the harvesting or scavenging of ambient vibrations has been extensively studied over the last decade. The energy conversion from mechanical (vibratory) to electrical energy is provided by the electromechanical coupling between mechanical strains/stresses and electric charges/voltages in the piezoelectric material. The majority of the studies found in the open literature present a tip-mass cantilever piezoelectric device tuned on the operating frequency. Although recent results show that these devices can be quite effective for harvesting small amounts of electrical energy, little has been published on the robustness of these devices or on the effect of parametric uncertainties on the energy harvested. This work focuses on a cantilever plate with bonded piezoelectric patches and a tip-mass serving as an energy harvesting device. The rectifier and storage electric circuit was replaced by a resistive circuit (R). In addition, an alternative to improve the harvesting performance by adding an inductance in series to the harvesting circuit, thus leading to a resonant circuit (RL), is considered. A coupled finite element model leading to mechanical (displacements) and electrical (charges at electrodes) degrees of freedom is considered. An analysis of the effect of parametric uncertainties of the device on the electric output is performed. Piezoelectric and dielectric constants of the piezoelectric active layers and electric circuit equivalent inductance are considered as stochastic parameters. Mean and confidence intervals of the electric output are evaluated.