8 resultados para Shoe Factory.

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Unstable shoes have been designed to promote "natural instability" and during walking they should simulate barefoot gait, enhancing muscle activity and, thus, attributing an advantage over regular tennis shoes. Recent studies showed that, after special training on the appropriate walking pattern, the use of the Masai Barefoot Technology (MBT) shoe increases muscle activation during walking. Our study presents a comparison of muscle activity as well as horizontal and vertical forces during gait with the MBT, a standard tennis shoe and barefoot walking of healthy individuals without previous training. These variables were compared in 25 female subjects and gait conditions were compared using ANOVA repeated measures (effect size:0.25). Walking with the MBT shoe in this non-instructed condition produced higher vertical forces (first vertical peak and weight acceptance rate) than walking with a standard shoe or walking barefoot, which suggests an increase in the loads received by the musculoskeletal system, especially at heel strike. Walking with the MBT shoe did not increase muscle activity when compared to walking with the standard shoe. The barefoot condition was more effective than the MBT shoe at enhancing muscle activation. Therefore, in healthy individuals, no advantage was found in using the MBT over a standard tennis shoe without a special training period. Further studies using the MBT without any instruction over a longer period are needed to evaluate if the higher loads observed in the present study would return to their baseline values after a period of adaptation, and if the muscle activity would increase over time. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Recent studies have shown an important reduction of joint overload during locomotion in elderly women with knee osteoarthritis (OA) after short- term use of minimalist shoes. Our aim is to investigate the chronic effect of inexpensive and minimalist footwear on the clinical and functional aspects of OA and gait biomechanics of elderly women with knee OA. Methods/Design: Fifty-six elderly women with knee OA grade 2 or 3 (Kellgren and Lawrence) are randomized into blocks and allocated to either the intervention group, which will use flexible, non-heeled shoes-Moleca (R)-for six months for at least six hours daily, or the control group, which could not use these shoes. Neither group is undergoing physical therapy treatment throughout the intervention period. Moleca (R) is a women's double canvas, flexible, flat walking shoe without heels, with a 5-mm anti-slip rubber sole and a 3-mm internal wedge of ethylene vinyl acetate. Both groups will be followed for six months and will be assessed at baseline condition, after three months, and after six months (end of intervention). All the assessments will be performed by a physiotherapist that is blind to the group allocation. The primary outcome is the pain Western Ontario and McMaster Universities Osteoarthritis (WOMAC) score. The secondary outcomes are global WOMAC score; joint stiffness and disability WOMAC scores; knee pain with a visual analogue scale; walking distance in the six-minute walk test; Lequesne score; amount and frequency (number of days) of paracetamol (500 mg) intake over six months; knee adduction moment during gait; global medical assessment score; and global patient auto-assessment score. At baseline, all patients receive a diary to record the hours of daily use of the footwear intervention; every two weeks, the same physiotherapist makes phone calls to all patients in order to verify adherence to treatment. The statistical analysis will be based on intention to treat analysis, as well as general linear models of analysis of variance for repeated measure to detect treatment-time interactions (alpha = 5%). Discussion: This is the first randomized, clinical trial protocol to assess the chronic effect of minimalist footwear on the clinical and functional aspects and gait biomechanics of elderly women with knee osteoarthritis. We expect that the use of Moleca (R) shoes for six months will provide pain relief, reduction of the knee adduction moment when walking, and improve joint function in elderly women with knee OA, and that the treatment, thus, can be considered another inexpensive and easy-to-use option for conservative OA treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The article discusses the trajectory of Manuel Luis da Veiga which, as a merchant in Portugal (where he was born) invested to install a factory in Pernambuco after the arrival of Real Family in the Rio de Janeiro, considering the changes, in these days, in the Portuguese Empire. It focuses the political sociabilities, remarking the role of Veiga in the court and his writings on political economy, understanding both as two linked dimensions of his social practice. It points out that his trajectory shows a deeply changing world in terms of paradigms, impossible to be understood simply in patterns of what was old or new in the beginning of XIX century.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The practice of running has consistently increased worldwide, and with it, related lower limb injuries. The type of running surface has been associated with running injury etiology, in addition other factors, such as the relationship between the amount and intensity of training. There is still controversy in the literature regarding the biomechanical effects of different types of running surfaces on foot-floor interaction. The aim of this study was to investigate the influence of running on asphalt, concrete, natural grass, and rubber on in-shoe pressure patterns in adult recreational runners. Forty-seven adult recreational runners ran twice for 40 m on all four different surfaces at 12 +/- 5% km . h(-1). Peak pressure, pressure-time integral, and contact time were recorded by Pedar X insoles. Asphalt and concrete were similar for all plantar variables and pressure zones. Running on grass produced peak pressures 9.3% to 16.6% lower (P < 0.001) than the other surfaces in the rearfoot and 4.7% to 12.3% (P < 0.05) lower in the forefoot. The contact time on rubber was greater than on concrete for the rearfoot and midfoot. The behaviour of rubber was similar to that obtained for the rigid surfaces - concrete and asphalt - possibly because of its time of usage (five years). Running on natural grass attenuates in-shoe plantar pressures in recreational runners. If a runner controls the amount and intensity of practice, running on grass may reduce the total stress on the musculoskeletal system compared with the total musculoskeletal stress when running on more rigid surfaces, such as asphalt and concrete.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Twelve participants ran (9 km . h(-1)) to test two types of running shoes: replica and original shoes. Ground reaction force, plantar pressure and electromyographic activity were recorded. The shoes were tested randomly and on different days. Comparisons between the two experimental conditions were made by analysis of variance (ANOVA) test (P <= 0.05). The time to first peak, loading rate of the first peak and impulse of the first 75 ms of stance were significantly different between the shoes (P <= 0.05), revealing an increase of impact forces for the replica shoes. The peak plantar pressure values were significantly higher (P <= 0.05) when wearing replica shoes. During running, the contact area was significantly smaller (P <= 0.05) for the replica shoe. The electromyographic activity of the analysed muscles did not show changes between the two shoes in running. These findings suggest that the use of replica running shoes can increase the external load applied to the human body, but may not change the muscle activity pattern during locomotion. This new mechanical situation may increase the risk of injuries in these movements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lactic acid bacteria (LAB) are an attractive and safe alternative for the expression of heterologous proteins, as they are nonpathogenic and endotoxin-free organisms. Lactococcus lactis, the LAB model organism, has been extensively employed in the biotechnology field for large-scale production of heterologous proteins, and its use as a "cell factory" has been widely studied. We have been particularly interested in the use of L. lactis for production of heat shock proteins (HSPs), which reportedly play important roles in the initiation of innate and adaptive immune responses. However, this activity has been questioned, as LPS contamination appears to be responsible for most, if not all, immunostimulatory activity of HSPs. In order to study the effect of pure HSPs on the immune system, we constructed recombinant L. lactis strains able to produce and properly address the Mycobacterium leprae 65-kDa HSP (Hsp65) to the cytoplasm or to the extracellular medium, using a xylose-induced expression system. Approximately 7 mg/L recombinant Hsp65 was secreted. Degradation products related to lactococcal HtrA activity were not observed, and the Limulus amebocyte lysate assay demonstrated that the amount of LPS in the recombinant Hsp65 preparations was 10-100 times lower than the permitted levels established by the U. S. Food and Drug Administration. These new L. lactis strains will allow investigation of the effects of M. leprae Hsp65 without the interference of LPS; consequently, they have potential for a variety of biotechnological, medical and therapeutic applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os acidentes são fenômenos complexos, cuja determinação situa-se na organização do trabalho, dimensão invisível aos agentes de vigilância. O objetivo deste artigo é analisar e comparar o alcance das intervenções realizadas em uma empresa frigorífica, em 1997, baseada na checagem de normas de saúde e segurança, e em 2008, quando se incorpora a ergonomia da atividade. Foi realizado estudo de caso com análise documental referente à intervenção de 1997 e análise ergonômica do trabalho adotada em 2008. Em 1997 as ações de vigilância incidiram principalmente sobre os fatores de risco visíveis. Mesmo cumprindo as exigências, a empresa continuava, em 2008, com proporção de incidência anual de 26% de acidentes, o que motivou a busca da nova abordagem. Verificou-se, em 2008, que a gênese dos acidentes era provocada por um circulo vicioso: trabalho intenso; inadequação de meios técnicos; absenteísmo e rotatividade (84% ao ano) com recrutamento de inexperientes. Esse quadro é agravado por práticas autoritárias. A ergonomia da atividade contribuiu para compreender as causas organizacionais ultrapassando os aspectos normativos da vigilância tradicional, o que indica sua importância para tornar mais efetivas as ações de vigilância para a prevenção.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O trabalho tem como foco a análise do processo produtivo de painéis maciços feitos como tábuas e cavilhas de madeira ("stack-board") em uma fábrica austríaca, visando identificar seus pontos positivos e negativos e fornecer uma visão geral de algumas das principais variáveis envolvendo a manufatura desse produto.