3 resultados para Servo-Kroatisch.

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the new active absorption wave basin, named Hydrodynamic Calibrator (HC), constructed at the University of São Paulo (USP), in the Laboratory facilities of the Numerical Offshore Tank (TPN). The square (14 m 14 m) tank is able to generate and absorb waves from 0.5 Hz to 2.0 Hz, by means of 148 active hinged flap wave makers. An independent mechanical system drives each flap by means of a 1HP servo-motor and a ball-screw based transmission system. A customized ultrasonic wave probe is installed in each flap, and is responsible for measuring wave elevation in the flap. A complex automation architecture was implemented, with three Programmable Logic Computers (PLCs), and a low-level software is responsible for all the interlocks and maintenance functions of the tank. Furthermore, all the control algorithms for the generation and absorption are implemented using higher level software (MATLAB /Simulink block diagrams). These algorithms calculate the motions of the wave makers both to generate and absorb the required wave field by taking into account the layout of the flaps and the limits of wave generation. The experimental transfer function that relates the flap amplitude to the wave elevation amplitude is used for the calculation of the motion of each flap. This paper describes the main features of the tank, followed by a detailed presentation of the whole automation system. It includes the measuring devices, signal conditioning, PLC and network architecture, real-time and synchronizing software and motor control loop. Finally, a validation of the whole automation system is presented, by means of the experimental analysis of the transfer function of the waves generated and the calculation of all the delays introduced by the automation system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aims of this work are: (i) to produce new experimental data for fretting fatigue considering the presence of a mean bulk stress and (ii) to assess two design methodologies against failure by fretting fatigue. Tests on a cylinder–flat contact configuration were conducted using a fretting apparatus mounted on a servo-hydraulic machine. The material used for both the pads and fatigue specimen was an aeronautical 7050-T7451 Al alloy. The experimental program was designed with all relevant parameters, apart from the mean bulk load (always applied before the contact loads), kept constant. The mean bulk stress varied from compressive to tensile values while maintaining a high peak pressure in order to encourage crack initiation. Two methodologies against fretting fatigue are proposed and confronted against the experimental data. The non-local stress-based methodology considers the evaluation of a critical plane fatigue criterion at the center of a process zone located beneath the contacting surfaces. The results showed that it correctly predicts crack initiation, but was not capable to provide successful prediction of the integrity of the specimens. Alternatively, we considered a crack arrest criterion which has the potential to provide a more complete description about the integrity of the specimens.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rationale: NAVA is an assisted ventilatory mode that uses the electrical activity of the diaphragm (Edi) to trigger and cycle the ventilator, and to offer inspiratory assistance in proportion to patient effort. Since Edi varies from breath to breath, airway pressure and tidal volume also vary according to the patient's breathing pattern. Our objective was to compare the variability of NAVA with PSV in mechanically ventilated patients during the weaning phase. Methods: We analyzed the data collected for a clinical trial that compares PSV and NAVA during spontaneous breathing trials using PSV, with PS of 5 cmH2O, and NAVA, with Nava level titrated to generate a peak airway pressure equivalent to PSV of 5 cmH2O (NCT01137271). We captured flow, airway pressure and Edi at 100Hz from the ventilator using a dedicated software (Servo Tracker v2, Maquet, Sweden), and processed the cycles using a MatLab (Mathworks, USA) code. The code automatically detects the tidal volume (Vt), respiratory rate (RR), Edi and Airway pressure (Paw) on a breath-by-breath basis for each ventilatory mode. We also calculated the coefficient of variation (standard deviation, SD, divided by the mean). Results: We analyzed data from eleven patients. The mean Vt was similar on both modes (370 ±70 for Nava and 347± 77 for PSV), the RR was 26±6 for Nava and 26±7 or PSV. Paw was higher for Nava than for PSV (14±1 vs 11±0.4, p=0.0033), and Edi was similar for both modes (12±8 for Nava and 11±6 for PSV). The variability of the respiratory pattern, assessed with the coefficient of variation, was larger for Nava than for PSV for the Vt ( 23%±1% vs 15%±1%, p=0.03) and Paw (17%±1% vs 1% ±0.1%, p=0.0033), but not for RR (21% ±1% vs 16% ±8%, p=0.050) or Edi (33%±14% vs 39% ±16%,p=0.07). Conclusion: The variability of the breathing pattern is high during spontaneous breathing trials independent of the ventilatory mode. This variability results in variability of airway pressure and tidal volume, which are higher on Nava than on PSV. Our results suggest that Nava better reflects the normal variability of the breathing pattern during assisted mechanical ventilation.